Technical Library | 2023-09-13 13:07:16.0
Pneumatic stencil cleaning machines are a great way to improve the efficiency and effectiveness of your stencil cleaning process. These machines use compressed air to remove contaminants and debris from stencils, which can cause defects and reliability issues.
Technical Library | 2021-12-31 06:55:24.0
Any air entrapment in the potting compound can result in air bubbles that may cause performance problems in the finished component. Potting under vacuum is therefore frequently required to prevent air entrapment, especially with the increasingly small and complex assemblies required in today's electronics
Technical Library | 2021-12-31 06:56:02.0
Any air entrapment in the potting compound can result in air bubbles that may cause performance problems in the finished component. Potting under vacuum is therefore frequently required to prevent air entrapment, especially with the increasingly small and complex assemblies required in today's electronics
Technical Library | 2016-11-10 17:37:35.0
The demand for compute capability is growing rapidly fueling the ever rising consumption of power by data centers the worldwide. This growth in power consumption presents a challenge to data center total cost of ownership. Free-air cooling is one of the industrial trends in reducing power consumption, the power usage effectiveness (PUE) ratio, and the total cost of ownership (TCO). Free-air cooling is a viable approach in many parts of the world where the air is reasonably clean. In Eastern China, the poor quality of air, high in particle and gaseous contamination, is a major obstacle to free-air cooling. Servers exposed to outside air blowing in to data centers will corrode and fail at high rate. The poor reliability of hardware increase TCO dramatically. This paper describes a corrosion resistant server design suitable for reliable operation in a free-air cooling data center located in Eastern China where the indoor air quality can be as poor as ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers) severity level G3. An accelerated corrosion test method of verifying hardware reliability in the ASHRAE severity level G3 environment is also described.
Technical Library | 2021-12-22 01:35:51.0
As a speed type air compressor, centrifugal compressor can generate air flow moving in radial direction. Centrifugal air compressors are used by a large number of companies today because of their high-pressure tightness. Therefore, common faults in the operation have become one of the most concerned issues for users. This article will discuss causes of centrifugal compressor failures and give corresponding maintenance measures. At the end, OKmarts has listed the problems and solutions in detail for your quick reference.
Technical Library | 2024-01-08 18:44:00.0
Printed circuit boards, especially multilayer, flexible and rigid-flexible printed circuit boards, are extremely hygroscopic, i.e. they absorb and bind the moisture in the air. A dried polyimide film, for example, will have reached its moisture saturation level again after just a few hours.
Technical Library | 1999-08-09 11:11:55.0
A great deal of controversy continues to surround the use of Hot Air Solder Leveling (HASL) in the production of printed circuit boards (PCBs). The financial burden, technological limitations and environmental issues surrounding the HASL process continue to grow. This requires an in-depth review by the printed circuit board manufacturing plant, as well as the assembly operation and instrument designers ( OEMs), to determine what alternative surface finishes are appropriate.
Technical Library | 2014-07-17 17:01:10.0
Embedded computing systems used in many military and avionics applications are trending toward higher heat fluxes, and as a result performance is being hindered by thermal limitations. This is intensified by the high ambient conditions experience by today’s modern warfighter. In many applications liquid cooling is replacing air flow through chassis for both thermal and environmental benefits(...) This paper outlines a series of passive thermal improvements which are easily integrated into legacy, or existing, systems and can provide a 3-4x increase in dissipated power.
Technical Library | 2017-06-22 17:11:53.0
C-mode scanning acoustic microscopy (C-SAM) is a non-destructive inspection technique showing the internal features of a specimen by ultrasound. The C-SAM is the preferred method for finding “air gaps” such as delamination, cracks, voids, and porosity. This paper presents evaluations performed on various advanced packages/assemblies especially flip-chip die version of ball grid array/column grid array (BGA/CGA) using C-SAM equipment. For comparison, representative x-ray images of the assemblies were also gathered to show key defect detection features of the two non-destructive techniques.
1 |