Technical Library: cooling zone cleaning (Page 1 of 1)

Function and Operational Theory of Condenser Tube Flux Collection System

Technical Library | 2023-01-17 17:50:59.0

Heller's new Condenser Tube Flux Recovery System is designed to provide more efficient flux collection than earlier Heller flux collection systems; while providing minimal down time for inspection and cleaning. The entire system easily fits within the rear of the top shell of an 1800-EXL oven. The system utilizes a different set of top shell caps specially designed to provide the best serviceability of both the flux collection system and maintenance of the heater zone blower motors.

Heller Industries Inc.

Cleaning

Technical Library | 2019-05-23 10:38:07.0

Solvent and co-solvent cleaning involves the use of engineered solvents in a vapor phase system. The solvents classically used were Class 1 Ozone Depleting Substances, but new types of solvents have been developed that are less environmentally harmful. In some cases, isopropyl alcohol is used with a co-solvent. In these types of cleaning systems, a cloud of boiling vapor solvent is maintained between a boil sump and a cooling coil. When the items to be cleaned are immersed in the vapor cloud, the solvent condenses on the assemblies and acts to dissolve the residues. These processes usually involve a final rinse step outside of the vapor cloud to ensure that all dissolved residues are washed off the assemblies (Figure 1).

ACI Technologies, Inc.

Reduce Pollution of Process Gasses in an Air Reflow Oven

Technical Library | 2019-07-02 23:02:05.0

The introduction of lead-free solders resulted in a selection of different chemistries for solder pastes. The higher melting points of lead-free alloys required thermal heat resistant rosin systems and activators that are active at elevated temperatures. As a result, more frequent maintenance of the filtration systems is required and machine downtime is increased.Last year a different method of cleaning reflow ovens was introduced. Instead of cooling down the process gasses to condensate the residues, a catalyst was used to maintain the clean oven. Catalytic thermal oxidation of residues in the nitrogen atmosphere resulted in cleaner heating zones. The residues were transformed into carbon dioxide. This remaining small amount of char was collected in the catalyst. In air ovens the catalyst was not seen as a beneficial option because the air extracted out of the oven was immediately exhausted into the environment. When a catalyst is used in an air environment there is not only the carbon dioxide residues, but also water. When a catalyst is used in an air reflow oven the question is where the water is going to. Will it condensate in the process part of the oven or is the gas temperature high enough to keep it out of the process area? A major benefit of using a catalyst to clean the air before it is exhausted into the environment is that the air pollution is reduced dramatically. This will make environmental engineers happy and result in less pollution of our nature. Apart from this, the exhaust tubes remain clean which reduces the maintenance of air ovens.This paper will give more detailed information of catalyst systems during development and performance in production lines.

Vitronics Soltec

Corrosion Resistant Servers for Free-Air Cooling Data Centers

Technical Library | 2016-11-10 17:37:35.0

The demand for compute capability is growing rapidly fueling the ever rising consumption of power by data centers the worldwide. This growth in power consumption presents a challenge to data center total cost of ownership. Free-air cooling is one of the industrial trends in reducing power consumption, the power usage effectiveness (PUE) ratio, and the total cost of ownership (TCO). Free-air cooling is a viable approach in many parts of the world where the air is reasonably clean. In Eastern China, the poor quality of air, high in particle and gaseous contamination, is a major obstacle to free-air cooling. Servers exposed to outside air blowing in to data centers will corrode and fail at high rate. The poor reliability of hardware increase TCO dramatically. This paper describes a corrosion resistant server design suitable for reliable operation in a free-air cooling data center located in Eastern China where the indoor air quality can be as poor as ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers) severity level G3. An accelerated corrosion test method of verifying hardware reliability in the ASHRAE severity level G3 environment is also described.

IBM Corporation

  1  

cooling zone cleaning searches for Companies, Equipment, Machines, Suppliers & Information