Technical Library: corrosive (Page 1 of 5)

SMT Placement Machine Nozzle Maintenance and Operation Instructions from KINGSUN

Technical Library | 2023-08-14 09:06:53.0

In the operation of SMT mounter, the process and integrity of the nozzle of the mounter will have a significant impact on the performance of the machine. As one of the important components of the SMT machine, it is necessary for us to carry out daily maintenance and upkeep of the SMT nozzle. To ensure that the suction nozzle of the SMT machine is intact before operation, how should we do a good job of maintaining the suction nozzle of the SMT machine during normal use? KINGSUN technical team analysis operation has the following main points: 1.Wipe the surface of the SMT nozzle with a dust-free cloth. 2.The small aperture nozzle can be passed through with a thin steel wire and then blown with an air gun. 3.The surface of the nozzle should not be soaked with corrosive solution such as alcohol, as this may cause the surface to fall off. 4.HOLDER should use a cotton swab to wipe the cavity and not damage the filter screen. 5.Regular addition of special grease to HOLDER claws. 6.According to production, it is best to regularly maintain and do other maintenance regularly. (* Suitable for Yamaha SMT machine nozzles , JUKI SMT machine nozzles, Samsung SMT machine nozzles, Panasonic SMT machine nozzles, Fuji SMT machine nozzles, Siemens SMT machine nozzles etc.) Regarding the SMT machine nozzle daily maintenance operation instructions, KINGSUN share with you here , hoping to be helpful to you. More information about Products please Contact US at jenny@ksunsmt.com or visit www.ksunsmt.com , thanks.

DONGGUAN KINGSUN AUTOMATION TECHNOLOGY CO.,LTD

Conformal Coating Process Characterization Considerations

Technical Library | 2013-09-25 20:57:24.0

Conformal coating is an enabling process that allows for the ruggedizing of electronic devices and modules. As the process increases the durability of electronics that are subjected to various end-use environmental conditions, it adds value to the product. While it does add value, consumers and manufacturers expect the electronics to work when subjected to dirt, humidity, moisture, corrosive materials, and various other contaminants. This expectation results in a drive to minimize the cost of the process. The lowest cost of ownership for a conformal coating process occurs by utilizing automated selective conformal coating equipment.

ASYMTEK Products | Nordson Electronics Solutions

Utility of Dual Applicators for Non-Atomized Conformal Coating to Improve High-Volume Manufacturing Optimization

Technical Library | 2017-12-07 10:35:50.0

Electronics manufacturers protect their circuit boards with conformal coatings. Conformal coatings serve as a barrier from environmental hazards and internal shorts, tin whiskers, and corrosion at the board level. Within conformal coatings different material chemistries specialize in shielding from an array of hazards and can be applied by multiple methods. The most common method is atomized spray which disperses the material into a fine mist. Alternatively, non-atomized coating controls the materials' dispense shape while maintaining the original liquid form. While some applications demand atomized spray and other scenarios overlap between atomized and non-atomized coating, this paper focuses on the circumstances where materials are ideally suited for non-atomized, selective coating.

ASYMTEK Products | Nordson Electronics Solutions

High Phosphorus ENIG – highest resistance against corrosive environment

Technical Library | 2023-01-10 20:15:42.0

Over the past years there has been consistent growth in the use of electroless nickel / immersion gold (ENIG) as a final finish. The finish is now frequently being used for PBGA, CSP, QFP and COB and more recently gathered considerable interest as a low cost under-bump metallization for flip chip bumping application. One of the largest users for this finish has been the telecommunication industry, were millions of square meters of PCBs with ENIG have been successfully used. The nickel layer offers advantages such as multiple soldering cycles and hand reworks without copper dissolution being a factor. The nickel also acts as a reinforcement to improve through-hole and blind micro via thermal integrity. In addition the nickel layer offers advantages such as co-planarity, Al-wire bondability and the use as contact surface for keypads or contact switching. Especially those pads, which are not covered by solder need a protective coating in corrosive environment – such as high humidity or pollutant gas.

Atotech

A Review of Corrosion and Environmental Effects on Electronics

Technical Library | 2013-08-01 13:17:44.0

Electronic industry uses a number of metallic materials in various forms. Also new materials and technology are introduced all the time for increased performance. In recent years, corrosion of electronic systems has been a significant issue. Multiplicity of materials used is one reason limiting the corrosion reliability. However, the reduced spacing between components on a printed circuit board (PCB) due to miniaturization of device is another factor that has made easy for interaction of components in corrosive environments. Presently the knowledge on corrosion issues of electronics is very limited. This paper reviews briefly the materials used in electronic systems, factors influencing corrosion, types of corrosion observed in electronics, and testing methods.

Technical University of Denmark

Investigation of Factors That Influence Creep Corrosion

Technical Library | 2021-04-08 00:36:50.0

Understand the sensitivities of the identified factors to Creep Corrosion. Correlate experimental test conditions to environment classification standards.

iNEMI (International Electronics Manufacturing Initiative)

Creep Corrosion Of Electronic Assemblies In Harsh Environments

Technical Library | 2022-03-16 19:41:17.0

Creep corrosion occurs in electronics assemblies and it is reminiscent to electromigration but does not require electrical field to drive the reaction. Corrosive elements and moisture must be present for creep corrosion to occur. Sulfur is the most prominent element to cause creep corrosion in environments such as paper mills, rubber manufacturing, mining, cement manufacturing, waste water treatment etc., also including companies and locations nearby such industries. The main part of printed circuit board assembly (PCBA) to be affected is the PCB surface finish. Especially immersion silver is prone to creep corrosion, but it sometimes occurs in NiPd (lead frames), and to a lesser extent in ENIG and OSP surface finishes. As the use of immersion silver is increasing as PCB surface finish and electronics are more and more used in harsh environments, creep corrosion is a growing risk. In this paper we will present the driving forces and mechanisms as well as suitable tests and mitigation strategies against creep corrosion

DfR Solutions (acquired by ANSYS Inc)

Relative Humidity Dependence of Creep Corrosion on Organic-Acid Flux Soldered Printed Circuit Boards

Technical Library | 2018-05-09 22:15:29.0

Creep corrosion on printed circuit boards (PCBs) is the corrosion of copper metallization and the spreading of the copper corrosion products across the PCB surfaces to the extent that they may electrically short circuit neighboring features on the PCB. The iNEMI technical subcommittee on creep corrosion has developed a flowers-of-sulfur (FOS) based test that is sufficiently well developed for consideration as an industry standard qualification test for creep corrosion. This paper will address the important question of how relative humidity affects creep corrosion. A creep corrosion tendency that is inversely proportional to relative humidity may allow data center administrators to eliminate creep corrosion simply by controlling the relative humidity in the data center,thus, avoiding the high cost of gas-phase filtration of gaseous contamination. The creep corrosion relative humidity dependence will be studied using a modified version of the iNEMI FOS test chamber. The design modification allows the achievement of relative humidity as low as 15% in the presence of the chlorine-releasing bleach aqueous solution. The paper will report on the dependence of creep corrosion on humidity in the 15 to 80% relative humidity range by testing ENIG (gold on electroless nickel), ImAg (immersion silver) and OSP (organic surface preservative) finished PCBs, soldered with organic acid flux.

iNEMI (International Electronics Manufacturing Initiative)

Effectiveness of Conformal Coat to Prevent Corrosion of Nickel-palladium-gold-finished Terminals

Technical Library | 2015-03-26 19:16:03.0

Nickel-palladium-gold-finished terminals are susceptible to creep corrosion. Excessive creep corrosion can result in device failure due to insulation resistance loss between adjacent terminals. The mixed flowing gas test has been demonstrated to produce creep corrosion on parts with nickel-palladium-gold finished terminals. Conformal coats are often used to protect printed wiring assemblies from failure due to moisture and corrosion. However, coating may not be sufficient to protect lead terminations from failure.In this study, acrylic, silicone, urethane, parylene, and atomic layer deposit (ALD) coatings were examined for their effectiveness at preventing corrosion of nickel-palladium-gold-finished terminals.

University of Maryland

Testing Printed Circuit Boards for Creep Corrosion in Flowers of Sulfur Chamber

Technical Library | 2015-07-16 17:24:23.0

Qualification of electronic hardware from a corrosion resistance standpoint has traditionally relied on stressing the hardware in a variety of environments. Before the development of tests based on mixed flowing gas (MFG), hardware was typically exposed to temperature-humidity cycling. In the pre-1980s era, component feature sizes were relatively large. Corrosion, while it did occur, did not in general degrade reliability. There were rare instances of the data center environments releasing corrosive gases and corroding hardware. One that got a lot of publicity was the corrosion by sulfur-bearing gases given off by data center carpeting. More often, corrosion was due to corrosive flux residues left on as-manufactured printed circuit boards (PCBs) that led to ion migration induced electrical shorting. Ion migration induced failures also occurred inside the PCBs due to poor laminate quality and moisture trapped in the laminate layers.

iNEMI (International Electronics Manufacturing Initiative)

  1 2 3 4 5 Next

corrosive searches for Companies, Equipment, Machines, Suppliers & Information