Electrostatic Discharge (ESD) - Sources of Electrostatic Charges in Production Line (SMT)

Technical Library | 2010-10-13 17:29:21.0

The number of failures caused by electrostatic discharges (ESD) has been increasing for some time now. So, it is necessary for everyone, who handles electrostatic sensitive devices (ESDS), to know the reasons of such failures. This presentation will give

B.E.STAT European ESD Competence Centre

Test Structures for Benchmarking the Electrostatic Discharge (ESD) Robustness of CMOS Technologies

Technical Library | 1999-08-05 10:34:17.0

This document defines a set of standard test structures with which to benchmark the electrostatic discharge (ESD) robustness of CMOS technologies. The test structures are intended to be used to evaluate the elements of an integrated circuit in the high current and voltage ranges characteristic of ESD events. Test structures are given for resistors, diodes, MOS devices, interconnects, silicon control rectifiers, and parasitic devices. The document explains the implementation strategy and the method of tabulating ESD robustness for various technologies.

SEMATECH

Preparing for Increased Electrostatic Discharge Device Sensitivity

Technical Library | 2015-10-08 17:40:35.0

With the push for ever improving performance on semiconductor component I/O interfaces, semiconductor components are being driven into a realm which makes them more sensitive to electrostatic discharge, potentially increasing in sensitivity by 50% every 3-5 years. Today, the majority of modern day semiconductor components are being designed to meet 250Volts of charge device model sensitivity, and that could decrease to 125Volts in the next 3-5 years, and could again decrease to 50Volts-70Volts in the following 3-5 years. The entire electronics industry must prepare for this challenge.

Intel Corporation

Hand Soldering, Electrical Overstress, and Electrostatic Discharge

Technical Library | 1999-05-09 13:07:16.0

This paper will give the reader a general understanding of EOS and ESD phenomena. It specifically addresses hand soldering's role in EOS and ESD and how to protect against and test for potential problems. It discusses how Metcal Systems address EOS and ESD concerns and how they differ from conventional soldering systems.

Metcal

A System Level Electrostatic Discharge Protection Modeling Methodology for Time Domain Analysis.

Technical Library | 2014-04-03 18:01:13.0

A system level modeling methodology is presented and validated on a simple case. It allows precise simulations of electrostatic discharge (ESD) stress propagation on a printed circuit board (PCB). The proposed model includes the integrated circuit (IC) ESD protection network, IC package, PCB lines, passives components, and externals elements. The impact of an external component on the ESD propagation paths into an IC is demonstrated. Resulting current and voltage waveforms are analyzed to highlight the interactions between all the elements of an operating PCB. A precise measurement technique was designed and used to compare with the simulation results. The model proposed in this paper is able to predict, with good accuracy, the propagation of currents and voltages into the whole system during ESD stress. It might be used to understand why failures occur and how to fix them with the most suitable solution.

Institute of Electrical and Electronics Engineers (IEEE)

Investigation of Device Damage Due to Electrical Testing

Technical Library | 2012-12-14 14:28:20.0

This paper examines the potential failure mechanisms that can damage modern lowvoltage CMOS devices and their relationship to electrical testing. Failure mechanisms such as electrostatic discharge (ESD), CMOS latch-up, and transistor gate oxide degradation can occur as a result of electrical over-voltage stress (EOS). In this paper, EOS due to electrical testing is examined and an experiment is conducted using pulsed voltage waveforms corresponding to conditions encountered during in-circuit electrical testing. Experimental results indicate a correlation between amplitude and duration of the pulse waveform and device degradation due to one or more of the failure mechanisms.

Worcester Polytechnic Institute

Introduction to the manufacturing process of anti static ic tubes

Technical Library | 2019-01-20 22:47:35.0

With the rapid development of the electronics industry, more and more components such as integrated circuits and connectors, relays, power modules, etc. need to be packaged with IC tubes. The anti static ic tubes is actually a kind of pvc plastic(reference to : What are the materials for IC tubes) profile, the size varies with the shape of the installed product, the precision requirement is high, the wall thickness should be controlled within ±0.1mm, and the surface is required to have no impurity spots, smooth and transparent. The IC packaging tubes produced by Sewate Technology Co., Ltd. are extruded. The typical process flow is: extrusion, vacuum adsorption setting, traction, fixed length cutting and directional discharge, deburring, immersion antistatic liquid, drying, testing, packaging and storage

Shenzhen Sewate Technology Co.,Ltd

Symor ESD storage dry cabinet(Working principle)

Technical Library | 2019-04-08 23:21:29.0

Climatest Symor® adopts molecular sieve to dry air, the whole system is controlled by microcomputer, when humidity is high, It will start to absorb moisture,when the humidity reach the pre-set value, it will stop absorbing, and then discharge the water to outside the cabinet by heating,again and again by automatic control. The most effective and environment-friendly moisture-absorbing desiccant is molecular sieve, molecular sieve is the microporous crystal material synthesized by silicon and aluminium oxide. In order to keep the crystal net discharge to be zero, atoms with cations are located in the crystal structure.and the cation used in these synthetic crystals is usually sodium. At present, there are two kinds of molecular sieves widely used in the dry box industry: Class A and Class X. Molecular sieves are synthesized, shaped and activated under strictly controlled production processes. The whole controlled sythesis process can ensure consistency of the three-dimensional pore size. 3A molecular sieve pore size is 3 angstroms, 4A molecular sieve pore size is 4 angstroms; 13X molecular sieve pore size is 8.5 angstroms. The working principle of molecular sieve: Molecular sieves adsorb molecules onto the crystal surface by physical attraction force. Since 95% surface area of the molecular sieve is within aperture,it needs to screen the adjacent molecules by different size. Only small size molecules can enter into the inner adsorption surface of the molecular sieve through the crystal aperture. This selective adsorption phenomenon is called molecular sieve effect. The molecular sieve adsorption capacity and charge density (polarity) are further related to the adsorbed molecules. The molecular sieves can further distinguish which of the mixed molecules can be adsorbed and determine to what extent the charge density can allow the molecules to be adsorbed onto the crystal. Water molecules are particularly small (2.6 angstroms), that belong to highly polar molecules (very strong positive and negative electron density), and are easily adsorbed by molecular sieves, even under very low moisture condition,once the water molecules are adsorbed,they will be firmly fixed on the crystal. The environment-friendly moisture absorption device is equipped with molecular sieve. When it’s absorbing, the memory alloy controller is in tensile state, and the spring is in contractive state,which just make the valve contact the outer baffle, this insulates the outside air from inside dry box air to achieve dehumidification purpose; and after molecular sieve absorbed moisture inside dry box and become saturated, the program will automatically control the memory alloy device to shrink it so that the valve reaches the inner baffle position. Meanwhile, due to the shrinkage of the memory alloy, the spring is stretched and the valve is pulled out of the outer baffle,so that the moisture in molecular sieve will be discharged into the outside. after the dehumidifying process finished, the program automatically control and reset the memory alloy and spring,to restart absorbing status.

Symor Instrument Equipment Co.,Ltd

How to settle it if there is water existed inside the compressor of temperature humidity chamber?

Technical Library | 2019-05-08 00:04:49.0

It is necessary to know there are some faults that cannot be entirely avoided during the use of temperature and humidity test chamber, but how to deal with them in time is a problem that needs to be paid attention to.Here mainly explain the temperature and humidity test chamber compressor in the reason for the water, and how to deal with it. Reason: water comes from air, because there is always water in the air, known as humidity, which is compressed into supersaturated air and then analyzed to become liquid. The oil comes from the lubrication system of the compressor, possibly because the wear clearance of the mechanism increases, and the lubricating oil will escape into the cylinder. Solution: after the compressor is removed from the temperature and humidity test chamber, with a larger gas storage tank, the oil and water will naturally settle down to the bottom of the jar, and we need to discharge regularly to reduce the oil and water content in the compressed air. Of course, you can also use filters and other things to further reduce the content of oil and water. if you need to know more details about climatic chamber, keep an eye on our website www.climatechambers.com

Symor Instrument Equipment Co.,Ltd

How to extend the lifespan of climatic test chamber?

Technical Library | 2019-05-06 23:13:09.0

Temperature and humidity test chamber has brought a lot of help to many industrial enterprises, but while it brings convenience to us, we should also take good care of them, otherwise they may be brought into the end-of-life phase ahead of time. The way of maintenance is also very simple. After daily use, the equipment is cleaned regularly, but the cleaning of the test chamber is also very skillful. If the operation is wrong, it may also lead to equipment failure. Let‘s learn how to extend the service life of the temperature and humidity test box together. 1, Pls clean the working room with water after each use, then dry the interior with dry cotton cloth. 2, Pls regularly remove dust from the evaporator inside the equipment, and periodically wipe the equipment to ensure clean and tidy. 3, When doing the test, the sample should be uniformly placed onto sample shelves,and the vent should not be blocked to prevent the influence of the test 4, It is necessary to pay attention to the cleaning of water tanks in peacetime, after the test or when the equipment is not intended to be used for a long time, all the water in the tank should be discharged, otherwise it will lead to the formation of scale inside the tank. The water used in the temperature and humidity test chamber must be pure or distilled water, or long-term use may result in a humidifier or internal pipe clogging. Above are the usual use notice of temperature and humidity test chamber, if customer adhere to the above several points,it is really able to prolong the service life of the equipment.

Symor Instrument Equipment Co.,Ltd

  1  