Technical Library: fail (Page 1 of 4)

Component Failure Analysis - Hermetic Packaging

Technical Library | 2019-06-11 09:34:37.0

Recently ACI Technologies was asked to perform failure analysis on a hermetically sealed transistor for potential electrostatic discharge (ESD) or electrostatic overstress (EOS). ACI was asked to determine if the field-failed transistor was damaged by ESD or EOS. In order to properly assess the failure, additional samples were requested.

ACI Technologies, Inc.

Corrosion Analysis

Technical Library | 2019-06-03 15:32:40.0

ACI Technologies was pleased to assist a customer by conducting elemental analysis on several assemblies displaying severe corrosion. Several board assemblies had failed in the field and exhibited areas of corrosion in close proximity to onboard components. The most common source of corrosion on electronic assemblies is residual flux. Fluxes are specific chemistries applied during the soldering process which improve the wetting of the solder to both the pad and component when forming the solder joint. They can be highly reactive chemicals that, if left on the assemblies, can lead to corrosion, electrical degradation, and decreased reliability. In the presence of moisture and electrical bias, flux residue can enable dendritic growth as a result of electrochemical migration (ECM).

ACI Technologies, Inc.

Lead-Free Control Plan

Technical Library | 2020-06-02 15:16:51.0

A commercial systems manufacturer working on a major defense program contacted the Helpline for urgent assistance with an issue of failed parts during reliability testing. They were attempting to incorporate commercial off-the-shelf (COTS) computer-related hardware into a battlefield system and were experiencing reliability issues. It was noted that the parts were labeled by the vendor as "compliant to military (or MIL) standards" but not clearly identified as tin-lead or lead-free. ACI Technologies has supported a number of customers with lead-free issues and we assisted the customer in developing a short term and long-term solution to their problem.

ACI Technologies, Inc.

BGA Reballing

Technical Library | 2019-05-30 10:59:13.0

In the current economic environment, the ability to reuse ball grid array(BGA) components that have failed due to solder defects may be an efficient way for electronics manufacturers to reduce costs. Cost may not be the only driving factor in the decision to engage in this recycling practice. The increasing demands placed upon the complexity of microprocessors and integrated circuits (ICs) has decreased the availability of some components, and increased their lead time. Because of this, reballing may provide a means to meet schedule, reduce rework turn-around time, and give a manufacturer a decisive advantage over other companies in an ever increasingly competitive market. This article will discuss the process of reballing BGA components (Figure 1), examining preparation (the preform method, the screen method), and cleaning and bake-out.

ACI Technologies, Inc.

Investigation of Through-Hole Capacitor Parts Failures Following Vibration and Stress Testing

Technical Library | 2019-06-21 10:39:15.0

Recently, an ACI Technologies (ACI) customer called to discuss failures that they had observed with some through-hole capacitor parts. The components were experiencing failures following vibration and accelerated stress testing. Upon receipt of the samples, ACI performed three levels of inspection and Energy Dispersive Spectroscopy (EDS) testing to investigate the root cause of the failures. These analyses enabled ACI to verify the elements comprising the solder joints and make the following recommendations in order to prevent future occurrences. The first inspection was to investigate the capacitor leads using optical microscopy, and no anomalies were found that could indicate bad parts from the vendor or improper handling prior to assembly. However, vertical fill in the barrel of the plated through-holes was too close to the IPC-A-610 minimum specification of 75% to determine a pass/fail condition, and therefore required further investigation.

ACI Technologies, Inc.

A Non-destructive Approach to Identify Intermittent Failure Locations on Printed Circuit Cards (PCC) that have been Temperature Cycle Tested

Technical Library | 2020-12-07 15:26:06.0

Temperature cycling testing is a method of accelerated life testing done to PCCs that are exposed to normal operation temperature variations over its lifetime. During the testing, intermittent "open" failures can first occur at the hot and cold extremes of the test, exposing weaknesses in the design and assembly. A poor/weak solder joint fatigues, a via trace or barrel cracks, loose connections or a component fails all causing an intermittent open. When not at extreme temperatures, the PCC assembly relaxes, the "open" closes creating electrical connectivity. If you are monitoring the PCC under test in-situ you will know that an intermittent failure has occurred, and the test could be stopped for inspection. If in-situ monitoring was not implemented, you would not know if there were intermittent failures or not. The PCC gets powered up and works fine at room temperature.

ACI Technologies, Inc.

Why salt spray chamber fail to spray salt mist?

Technical Library | 2019-11-20 22:44:25.0

Salt spray test chamber is used to test teh salt corrosion resistance ability of hardware, metal and other auto parts,the chamber can quickly detect the corrosion resistance degree of products in the temperature, humidity and salt spraying environment, which can effectively improve production efficiency. So what is the reason why such a salt spray test chamber does not spray? As per our past maintenance experience,there are below reasons,customers can have a look,hope it is helpful: 1, the spray tower is blocked; 2, water pipes clogged, water flow can not go in; 3, the air compressor stops running,pls open the air compressor button; 4, main switch of the air compressor outlet is not turned on,pls turn on. 5, the solenoid valve fails, the pressure meter is broken or the pressure is too low, pls check with Climatest and repair it. 6, when the nozzle is clogged, the nozzle should be carefully removed and cleaned,because it is fragile. 7, if the spray pressure is normal, the position of the nozzle glass is also correct, but what is the reason for not spraying? In this case, it is necessary to carefully observe whether there is dirt at the contact surface of the nozzle. If so, clean up the dirt and the spray can be carried out normally. That‘s all we‘re going to talk about today. If you have any questions, follow us on facebook, Please feel free to ask us questions.

Symor Instrument Equipment Co.,Ltd

Thermal Management of Electrolytic Capacitors

Technical Library | 1999-05-06 12:08:08.0

Input voltage capacitors are typically the parts that fail first in a high power circuit. Today's requirements for increasingly smaller packages is driving high component densities in power systems, as in all systems. As the package size...

Aavid Thermalloy, LLC

Understanding Creep Corrosion Field Fails

Technical Library | 2022-03-16 19:48:18.0

Dendrites, Electrochemical Migration (ECM) and parasitic leakage, are usually caused by process related contamination. For example, excess flux, poor handling, extraneous solder, fibers, to name a few. One does not normally relate these fails with environmental causes. However, creep corrosion is a mechanism by which electronic products fail in application, primarily related to sulfur pollution present in the air.1 The sulfur reacts with exposed silver, and to a lesser extent, exposed copper. This paper will explore various aspects of the creep corrosion chemical reaction

Foresite Inc.

Best Practices for Improving the PCB Supply Chain: Performing the Process Audit

Technical Library | 2018-08-03 14:37:59.0

In the electronics industry, the quality and reliability of any product is highly dependent upon the capabilities of the manufacturing suppliers. Manufacturing defects are one of the top reasons why companies fail to meet warranty expectations. These problems can result in severe financial pain and eventual loss of market share. What a surprising number of engineers and managers fail to realize is that focusing on processes addresses only part of the issue. Supplier selection also plays a critical role in the success or failure of the final product.

DfR Solutions

  1 2 3 4 Next

fail searches for Companies, Equipment, Machines, Suppliers & Information