Technical Library | 2023-01-17 17:50:59.0
Heller's new Condenser Tube Flux Recovery System is designed to provide more efficient flux collection than earlier Heller flux collection systems; while providing minimal down time for inspection and cleaning. The entire system easily fits within the rear of the top shell of an 1800-EXL oven. The system utilizes a different set of top shell caps specially designed to provide the best serviceability of both the flux collection system and maintenance of the heater zone blower motors.
Technical Library | 2023-08-18 03:28:47.0
Today, KINGSUN shares with you the common types and classifications of SMT mounters. 一、According to the feeding method, common ones include: 1.Tape Feeder 2.Tray Feeder 3.Tube Feeder 4.Stick Feeder 5.Special Vibration Feeder 二、According to the classification of electric and non electric, the common ones are electric feeder and mechanical feeder. Yamaha's SIGMA SMT machines are all electric feeders, while many of JUKI's feeder are mechanical feeders...... Regarding feeders related knowledge, KINGSUN share with you here , hoping to be helpful to you. More information about Products please Contact US at jenny@ksunsmt.com or visit www.ksunsmt.com . "DONGGUAN KINGSUN AUTOMATION TECHNOLOGY CO.,LTD" is a leading SMT automation equipment factory provider in China. With many years of profound experience accumulation, we provides comprehensive solutions for global customers with strong resources and high-quality professional technical team.
Technical Library | 2023-08-14 09:06:53.0
In the operation of SMT mounter, the process and integrity of the nozzle of the mounter will have a significant impact on the performance of the machine. As one of the important components of the SMT machine, it is necessary for us to carry out daily maintenance and upkeep of the SMT nozzle. To ensure that the suction nozzle of the SMT machine is intact before operation, how should we do a good job of maintaining the suction nozzle of the SMT machine during normal use? KINGSUN technical team analysis operation has the following main points: 1.Wipe the surface of the SMT nozzle with a dust-free cloth. 2.The small aperture nozzle can be passed through with a thin steel wire and then blown with an air gun. 3.The surface of the nozzle should not be soaked with corrosive solution such as alcohol, as this may cause the surface to fall off. 4.HOLDER should use a cotton swab to wipe the cavity and not damage the filter screen. 5.Regular addition of special grease to HOLDER claws. 6.According to production, it is best to regularly maintain and do other maintenance regularly. (* Suitable for Yamaha SMT machine nozzles , JUKI SMT machine nozzles, Samsung SMT machine nozzles, Panasonic SMT machine nozzles, Fuji SMT machine nozzles, Siemens SMT machine nozzles etc.) Regarding the SMT machine nozzle daily maintenance operation instructions, KINGSUN share with you here , hoping to be helpful to you. More information about Products please Contact US at jenny@ksunsmt.com or visit www.ksunsmt.com , thanks.
Technical Library | 2009-04-23 08:14:37.0
No SMT equipment can place accurately and run efficiently without quality nozzles and feeders. These two factors are the core of the pick and place process. If the machine is either unable to pick parts consistently or hold on to the components during the transport from feeder to PCB, defects will result.
Technical Library | 2020-03-08 11:35:53.0
A sample for Larry Bush's Maintenance Policies and Procedures - 2nd Edition (A 415-page book in PDF format. Those who purchase also receive 150 support files in editable format to customize and use as samples and templates.)
Technical Library | 1999-08-05 10:57:54.0
This study examines ergonomic stressors associated with front-end process tool maintenance, relates them to decreased machine utilization, and proposes solution strategies to reduce their negative impact on productivity.
Technical Library | 2018-05-05 21:37:12.0
With the growing demand for manufacturing facilities, authorities took many actions to escalate the efficiency of production processes. Many formal methods were implemented for a longer period of time without acquiring significant growth in the field. But with the introduction of Autonomous Maintenance (AM) to the modern manufacturing facilities they achieved an increment in efficiency and productivity in a historical brisk pace. This article is about AM Step Zero too.
Technical Library | 2008-05-14 15:44:58.0
This paper will review some basic past and present flux chemistries that affect flux collection methodology. It will also review some of the most common flux collection methods, self-cleaning techniques, and maintenance goals. And, finally, data will be presented from high volume production testing of an advanced flux management system.
Technical Library | 2021-12-22 01:35:51.0
As a speed type air compressor, centrifugal compressor can generate air flow moving in radial direction. Centrifugal air compressors are used by a large number of companies today because of their high-pressure tightness. Therefore, common faults in the operation have become one of the most concerned issues for users. This article will discuss causes of centrifugal compressor failures and give corresponding maintenance measures. At the end, OKmarts has listed the problems and solutions in detail for your quick reference.
Technical Library | 2019-05-21 00:21:26.0
Continue to talk about the dust removal from temperature humidity test chamber. Cleaning and maintenance: 1) Pls remove internal impurities inisde chamber before operation. 2) The power distribution room should be cleaned at least once a year, and the dust can be removed by vacuum cleaner. 3) The exterior chamber must also be cleaned more than once a year, which can be wiped with soapy water. Inspection and maintenance of humidifier: The water storage in humidifier should be replaced once a month to ensure clean water quality, humidifying water tray should be cleaned once a month to ensure smooth flow of water. The inspection of over-temperature protector:during the test: If the temperature is over 20 ℃ ~ 30 ℃ than the maximum value setted,the power supply of the heater will stop, the "OVERHEAT" overt-emperature warning light will automatically turn on but the fan is still in operation, if the equipment runs without operator around,the operator should check the over-temperature protector in advance to ensure wether it has been setted properly before start [wet ball over-temperature protector set to 120 ℃].