Technical Library: hardware initiation failed (Page 1 of 1)

Lead-Free Control Plan

Technical Library | 2020-06-02 15:16:51.0

A commercial systems manufacturer working on a major defense program contacted the Helpline for urgent assistance with an issue of failed parts during reliability testing. They were attempting to incorporate commercial off-the-shelf (COTS) computer-related hardware into a battlefield system and were experiencing reliability issues. It was noted that the parts were labeled by the vendor as "compliant to military (or MIL) standards" but not clearly identified as tin-lead or lead-free. ACI Technologies has supported a number of customers with lead-free issues and we assisted the customer in developing a short term and long-term solution to their problem.

ACI Technologies, Inc.

No-fault-found and intermittent failures in electronic products

Technical Library | 2022-12-05 16:22:13.0

This paper reviews the possible causes and effects for no-fault-found observations and intermittent fail- ures in electronic products and summarizes them into cause and effect diagrams. Several types of inter- mittent hardware failures of electronic assemblies are investigated, and their characteristics and mechanisms are explored. One solder joint intermittent failure case study is presented. The paper then discusses when no-fault-found observations should be considered as failures. Guidelines for assessment of intermittent failures are then provided in the discussion and conclusions.

CALCE Center for Advanced Life Cycle Engineering

Corrosion Resistant Servers for Free-Air Cooling Data Centers

Technical Library | 2016-11-10 17:37:35.0

The demand for compute capability is growing rapidly fueling the ever rising consumption of power by data centers the worldwide. This growth in power consumption presents a challenge to data center total cost of ownership. Free-air cooling is one of the industrial trends in reducing power consumption, the power usage effectiveness (PUE) ratio, and the total cost of ownership (TCO). Free-air cooling is a viable approach in many parts of the world where the air is reasonably clean. In Eastern China, the poor quality of air, high in particle and gaseous contamination, is a major obstacle to free-air cooling. Servers exposed to outside air blowing in to data centers will corrode and fail at high rate. The poor reliability of hardware increase TCO dramatically. This paper describes a corrosion resistant server design suitable for reliable operation in a free-air cooling data center located in Eastern China where the indoor air quality can be as poor as ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers) severity level G3. An accelerated corrosion test method of verifying hardware reliability in the ASHRAE severity level G3 environment is also described.

IBM Corporation

Why salt spray chamber fail to spray salt mist?

Technical Library | 2019-11-20 22:44:25.0

Salt spray test chamber is used to test teh salt corrosion resistance ability of hardware, metal and other auto parts,the chamber can quickly detect the corrosion resistance degree of products in the temperature, humidity and salt spraying environment, which can effectively improve production efficiency. So what is the reason why such a salt spray test chamber does not spray? As per our past maintenance experience,there are below reasons,customers can have a look,hope it is helpful: 1, the spray tower is blocked; 2, water pipes clogged, water flow can not go in; 3, the air compressor stops running,pls open the air compressor button; 4, main switch of the air compressor outlet is not turned on,pls turn on. 5, the solenoid valve fails, the pressure meter is broken or the pressure is too low, pls check with Climatest and repair it. 6, when the nozzle is clogged, the nozzle should be carefully removed and cleaned,because it is fragile. 7, if the spray pressure is normal, the position of the nozzle glass is also correct, but what is the reason for not spraying? In this case, it is necessary to carefully observe whether there is dirt at the contact surface of the nozzle. If so, clean up the dirt and the spray can be carried out normally. That‘s all we‘re going to talk about today. If you have any questions, follow us on facebook, Please feel free to ask us questions.

Symor Instrument Equipment Co.,Ltd

  1  

hardware initiation failed searches for Companies, Equipment, Machines, Suppliers & Information

SMTAI 2024 - SMTA International

World's Best Reflow Oven Customizable for Unique Applications
SMT feeders

High Precision Fluid Dispensers
convection smt reflow ovens

Software for SMT placement & AOI - Free Download.
Hot selling SMT spare parts and professional SMT machine solutions

Private label coffee for your company - your logo & message on each bag!