Technical Library | 2020-08-16 14:50:25.0
Not all desiccant bags are created or perform equally. Performance measures include: a) How long does desiccant last? b) How much are can be desiccated in a given area? c) How much moisture is retained, and or released back into the atmosphere? This article walks engineers through various test they can perform to determine efficacy. Additionally, the article highlight between adsorption vs adsorption.
Technical Library | 2007-09-13 16:58:52.0
With the use of laser light for reflow having been established, all that remains is to apply it to best effect. Each time a laser is fired, it pumps a specific amount of energy at a particular wavelength to a particular point in space. Where technique comes in is choosing where and for how long to apply that light along with the application of accessory equipment to optimize solder paste reflow. This presentation covers the specifics of how to determine which process choices are the right process choices based on the needs of your product to maximize yield and throughput.
Technical Library | 2009-10-22 02:38:13.0
An electronic product's reliability has the potential to make or break its manufacturer and can be life-threatening in many safety critical applications. Conformal coatings have long been used to protect electronic assemblies from their operating environment but can vary hugely in their protective performance. It is the objective of this article to explain in detail why it is important to qualify coating products to the relevant standards and how different coating types affect performance.
Technical Library | 2020-11-19 10:15:54.0
How to repair boards if they have been produced for a long time, and the documentation is lost? In this case, intelligent recognition systems can help, which will allow you to identify component pins without documentation for the board. In this article, we will find the STM32F429 board malfunctions without any documentation and in the least amount of time.
Technical Library | 2015-06-04 19:10:47.0
Integrators and designers of high-reliability systems exert little or no control over component-level plating processes that affect the propensity for tin whiskering. Challenges of how to assure long-term reliability, while continuing to use COTS parts plated with pure tin, continue to arise. An integrated, quantitative, standardized methodology is proposed whereby mitigation levels can be selected that are appropriate for specific applications of pure tin for given end-uses. A system of hardware end-use classification is proposed, together with recommended appropriate risk mitigation approaches. An updated version of the application-specific risk assessment algorithm is presented together with recommended thresholds for acceptability within the context of the hardware classifications.
Technical Library | 2019-05-16 02:25:15.0
limatest Symor wants to tell you that humidity is not only the most important thing in the chamber, but also the temperature In order to facilitate customers to add water, our temperature and humidity test chamber is to place the water tank at back of the equipment.Just open the baffle to see the water tank and the water level meter next to the tank,then add enough water to the tank. However, in addition to manual water addition, our temperature and humidity test chamber has equipment that can automatically add water. Only by connecting the water pipe at the water filling port can it be automatically replenished when there is a shortage of water, which is suitable for high humidity test for a long time.
Technical Library | 2016-10-24 14:59:03.0
Temperature measurement is one of the most important physical parameters when determining quality, accuracy and reliability of processes not only in industrial use, but also in almost all human activities. Temperature sensors are produced with different technologies to fit specific application requirements. IST AG has concentrated one part of the development and manufacturing on high-end thin-film temperature sensors. This know-how is partially derived from the semiconductor industry and allows us to manufacture sensors with high accuracy, excellent long-term stability, high reliability and repeatability within a wide temperature range from -200 °C up to 1000 °C. Because of very small dimensions and low thermal mass, the thin-film temperature sensors exhibit a very short response time.
Technical Library | 2021-12-08 01:19:32.0
In modern society, mobile phone is almost a necessity for everyone. When your mobile phone is not around, you may easily feel anxious as if something is missing, which is called nomophobia. In the past, people used to check if they had taken money when they went out. But now, mobile phone is the thing people must take. As is known to us, as long as you take a mobile phone, it's easy to get food, clothes, and to take transport. Look at our mobile phones, you will find almost all of them are equipped with touch screens now, which are much better than the early keyboard for using. So, how much do you know about HMI touch screens in industrial scenes?
Technical Library | 2019-05-06 23:13:09.0
Temperature and humidity test chamber has brought a lot of help to many industrial enterprises, but while it brings convenience to us, we should also take good care of them, otherwise they may be brought into the end-of-life phase ahead of time. The way of maintenance is also very simple. After daily use, the equipment is cleaned regularly, but the cleaning of the test chamber is also very skillful. If the operation is wrong, it may also lead to equipment failure. Let‘s learn how to extend the service life of the temperature and humidity test box together. 1, Pls clean the working room with water after each use, then dry the interior with dry cotton cloth. 2, Pls regularly remove dust from the evaporator inside the equipment, and periodically wipe the equipment to ensure clean and tidy. 3, When doing the test, the sample should be uniformly placed onto sample shelves,and the vent should not be blocked to prevent the influence of the test 4, It is necessary to pay attention to the cleaning of water tanks in peacetime, after the test or when the equipment is not intended to be used for a long time, all the water in the tank should be discharged, otherwise it will lead to the formation of scale inside the tank. The water used in the temperature and humidity test chamber must be pure or distilled water, or long-term use may result in a humidifier or internal pipe clogging. Above are the usual use notice of temperature and humidity test chamber, if customer adhere to the above several points,it is really able to prolong the service life of the equipment.
Technical Library | 2016-01-21 16:52:27.0
Solder paste has long been viewed as "black magic". This "black magic" can easily be dispelled through a solder paste evaluation. Unfortunately, solder paste evaluation can be a challenge for electronic assemblers. Interrupting the production schedule to perform an evaluation is usually the first hurdle. Choosing the solder paste properties to test is simple, but testing for these properties can be difficult. Special equipment or materials may be required depending upon the tests that are chosen. Once the testing is complete, how does one make the decision to choose a solder paste? Is the decision based on gut feel or hard data?This paper presents a process for evaluating solder pastes using a variety of methods. These methods are quick to run and are challenging, revealing the strengths and weaknesses of solder pastes. Methods detailed in this paper include: print volume, stencil life, response to pause, open time, tack force over time, wetting, solder balling, graping, voiding, accelerated aging, and others.