Mitigation of Pure Tin Risk by Tin-Lead SMT Reflow- Results of an Industry Round-Robin

Technical Library | 2017-10-12 15:45:25.0

The risk associated with whisker growth from pure tin solderable terminations is fully mitigated when all of the pure tin is dissolved into tin-lead solder during SMT reflow. In order to take full advantage of this phenomenon, it is necessary to understand the conditions under which such coverage can be assured. A round robin study has been performed by IPC Task group 8-81f, during which identical sets of test vehicles were assembled at multiple locations, in accordance with IPC J-STD-001, Class 3. All of the test vehicles were analyzed to determine the extent of complete tin dissolution on a variety of component types. Results of this study are presented together with relevant conclusions and recommendations to guide high reliability end-users on the applicability and limitations of this mitigation strategy.

Raytheon

How Clean is Clean Enough – At What Level Does Each of The Individual Contaminates Cause Leakage and Corrosion Failures in SIR?

Technical Library | 2016-09-08 16:27:49.0

In this investigation a test matrix was completed utilizing 900 electrodes (small circuit board with parallel copper traces on FR-4 with LPI soldermask at 6, 10 and 50 mil spacing): 12 ionic contaminants were applied in five concentrations to three different spaced electrodes with five replicas each (three different bare copper trace spacing / five replications of each with five levels of ionic concentration). The investigation was to assess the electrical response under controlled heat and humidity conditions of the known applied contamination to electrodes, using the IPC SIR (surface insulation resistance) J-STD 001 limits and determine at what level of contamination and spacing the ionic / organic residue has a failing effect on SIR.

Foresite Inc.

What causes temperature humidity chamber to alarm?

Technical Library | 2019-12-12 02:43:44.0

Today we discuss the reason that causes temperature humidity chamber to alarm,In most cases, the equipment alarm is caused by the improper operation in the process of use, which mainly includes following reasons:that are refrigeration system, temperature system and circulating system. First, Refrigeration system 1, refrigeration compressor overpressure alarm. If the refrigerant pressure exceeds the set value, it will stop and alarm at the same time. At this time, the fault must be eliminated and then manually reset. 2, short phase power supply, phase sequence alarm. When the external power supply of the equipment is out of phase or the phase sequence is changed, it will stop and alarm at the same time. 3. The circulating cooling water is short of water to alarm. When the water pressure of the cooling circulating water system is insufficient, it will stop and alarm at the same time, and it must wait for the fault to be eliminated and reset at the same time before it could run normally. 4, refrigeration compressor overheating alarm. When the coil of the compressor is overheated and the power supply of the line is not normal, it will stop and alarm at the same time. Second, Temperature system 1, the overtemperature alarm in the chamber. The sensors in the channel and the sample area are equipped with overtemperature protection devices, and there are also overtemperature protecter on the control panel. When the temperature in the working chamber exceeds the setting value on the controller, it will stop and alarm. 2. sample overtemperature protection. When the temperature in the sample area exceeds the protection temperature set by the controller, it will stop and alarm at the same time. The overtemperature protection of the sample is divided into upper limit protection and lower limit protection, which can be set according to the demand, Third,Circulating system 1. The alarm is caused by the overheating of the circulating fan. When the coil of the fan is over-heated, the alarm will be stopped at the same time. 2. The fan over-current alarm. When the current of the fan exceeds the allowable value, the alarm is stopped at the same time, and the normal operation can only be carried out after the fault maintenance of the overcurrent is completed. This is what we talk about today,if you have more questions,let us know.

Symor Instrument Equipment Co.,Ltd

Why we need to proceed temperature humidity test?

Technical Library | 2019-10-29 02:55:33.0

For every 10 ℃ increase in temperature, the reaction rate is twice to three times. This means that for every 10 ℃ increase in temperature, the life span of the product will be halved, and when the temperature rises by 20 ℃, the life span of the product will be reduced to 1/4. High temperature will lead to aging, oxidation, evaporation, physical deformation and so on. Low temperature will lead to embrittlement, ice formation, viscosity and solidification degree, loss of mechanical strength, physical shrinkage and so on. When the product is shipped, stored and operated in the environment, it will be endangered. In addition, each product has regulatory and certification requirements, and it is important to evaluate reliability and durability before it is put on the market. In general, according to the IEC60068 test standard, it requires the volume of the laboratory to be at least five times the total volume of the sample under test. Haida constant temperature and humidity box can help you meet this demand. So with the fast developmement of manufacturing industry,test becomes a necessity to see wether the product is able to meet regulated standards in R&D satge,Climatest Symor specializes in handling temperature and humidity,we supply environmental test chamber to China State-owned Research Institutes and laboratories,and obtain excellent reputation from international cllients,our company put much efforts on chamber R&D ,striving to supply best-quality climate simulation equipment and after-sale service. For details,pls visit our official website www.climatechambers.com

Symor Instrument Equipment Co.,Ltd

  1  

humidity according j-std-001 searches for Companies, Equipment, Machines, Suppliers & Information

Win Source Online Electronic parts

Software programs for SMT placement and AOI Inspection machines from CAD or Gerber.
Solder Paste Dispensing

Training online, at your facility, or at one of our worldwide training centers"
used smt parts china

Have you found a solution to REDUCE DISPENSE REWORK? Your answer is here.
IPC Training & Certification - Blackfox

Component Placement 101 Training Course
2024 Eptac IPC Certification Training Schedule

Software for SMT placement & AOI - Free Download.
Hot selling SMT spare parts and professional SMT machine solutions

Thermal Transfer Materials.