Technical Library: humidity control cabinets (Page 1 of 2)

DRY BOX DESICCANT STORAGE FOR PCB MANUFACTURING

Technical Library | 2023-09-23 22:31:52.0

Dry boxes can be implemented at various points within the Mfg. environment; for med-long term inventory, or for short term handling on the production floor, and in some cases (with certain conditions) as a process replacement for baking. Bare boards, raw components and partially assembled PCB's can benefit from ultra-low humidity storage.

XDry

Best Practices for Quality Control in Conformal Coating Applications

Technical Library | 2024-08-09 06:34:09.0

Quality control in conformal coating applications is vital for ensuring the reliability and longevity of electronic products. Conformal coatings protect printed circuit boards (PCBs) from environmental factors like moisture, dust, and chemicals. To maintain high standards, various inspection methods are employed throughout the coating process. Visual Inspection This is the first line of defense against defects. Inspectors look for uniform coverage, absence of bubbles, and proper curing. Training is essential to ensure that inspectors can identify subtle issues that may affect performance. UV Inspection Most conformal coatings contain a UV tracer, which makes the coating visible under ultraviolet light. UV inspection allows for easy detection of missed areas, ensuring complete coverage. This step is crucial for verifying that the coating has been applied correctly, especially in hard-to-see areas of the PCB. Automated Optical Inspection (AOI) AOI systems offer a more precise and consistent method for inspecting conformal coatings. They use cameras and specialized software to detect defects that might be missed by the human eye. AOI systems can inspect large volumes of PCBs quickly, making them ideal for high-production environments. Thickness Measurement The thickness of the conformal coating is critical for providing adequate protection without affecting the performance of the PCB. Tools such as micrometers, ultrasonic thickness gauges, and eddy current devices are used to measure the coating thickness. Consistent application is key to preventing issues like cracking or insufficient protection. Functional Testing Beyond visual and automated inspections, functional testing is necessary to ensure that the conformal coating does not interfere with the electrical performance of the PCB. This involves subjecting the coated PCB to environmental stress tests, such as thermal cycling, humidity, and salt spray, to assess its reliability in real-world conditions. Process Control and Documentation Implementing strict process controls is essential to maintaining quality. This includes regularly calibrating equipment, training operators, and documenting every step of the process. Proper documentation helps trace issues back to their source and prevents them from recurring. Conclusion Effective quality control in conformal coating applications ensures that PCBs are protected from environmental damage, thereby extending their lifespan and reliability. By employing a combination of visual, UV, and automated inspections, along with thickness measurement and functional testing, manufacturers can achieve the highest standards in coating quality.

I.C.T ( Dongguan ICT Technology Co., Ltd. )

What is humidity control dry cabinet?

Technical Library | 2019-05-17 01:50:39.0

Dry cabinet is especially designed with fully automatic humidity control to prevent moisture related defects. This cabinet is the optimal storage expert for SMT/BGA/PCB/IC electronic components.Our newly developed design greatly increases dehumidifying system which runs faster and more reliable compare to those traditional dry cabinets. it decreases the defective rate at production line.

Symor Instrument Equipment Co.,Ltd

What is usage of Electronic dry cabinet?

Technical Library | 2019-08-19 23:55:20.0

Electronic dry cabinet for MSD storage Humidity is one of the key reasons for rejected products, many manufacturers are taking measures to control the humidity to increase production efficiency and save cost. In semiconductor and electronic industry, the key section of rejected products mostly happen during SMT heating process, Climatest Symor® auto dry cabinet is a superior solution to avoid the cracking. Warranty: two years with lifetime technical support

Symor Instrument Equipment Co.,Ltd

What causes temperature humidity chamber to alarm?

Technical Library | 2019-12-12 02:43:44.0

Today we discuss the reason that causes temperature humidity chamber to alarm,In most cases, the equipment alarm is caused by the improper operation in the process of use, which mainly includes following reasons:that are refrigeration system, temperature system and circulating system. First, Refrigeration system 1, refrigeration compressor overpressure alarm. If the refrigerant pressure exceeds the set value, it will stop and alarm at the same time. At this time, the fault must be eliminated and then manually reset. 2, short phase power supply, phase sequence alarm. When the external power supply of the equipment is out of phase or the phase sequence is changed, it will stop and alarm at the same time. 3. The circulating cooling water is short of water to alarm. When the water pressure of the cooling circulating water system is insufficient, it will stop and alarm at the same time, and it must wait for the fault to be eliminated and reset at the same time before it could run normally. 4, refrigeration compressor overheating alarm. When the coil of the compressor is overheated and the power supply of the line is not normal, it will stop and alarm at the same time. Second, Temperature system 1, the overtemperature alarm in the chamber. The sensors in the channel and the sample area are equipped with overtemperature protection devices, and there are also overtemperature protecter on the control panel. When the temperature in the working chamber exceeds the setting value on the controller, it will stop and alarm. 2. sample overtemperature protection. When the temperature in the sample area exceeds the protection temperature set by the controller, it will stop and alarm at the same time. The overtemperature protection of the sample is divided into upper limit protection and lower limit protection, which can be set according to the demand, Third,Circulating system 1. The alarm is caused by the overheating of the circulating fan. When the coil of the fan is over-heated, the alarm will be stopped at the same time. 2. The fan over-current alarm. When the current of the fan exceeds the allowable value, the alarm is stopped at the same time, and the normal operation can only be carried out after the fault maintenance of the overcurrent is completed. This is what we talk about today,if you have more questions,let us know.

Symor Instrument Equipment Co.,Ltd

What is the application of moisture proof dry cabinet?

Technical Library | 2019-04-11 05:59:57.0

Are your MSD safely stored? As humidity is found to be one of the key reasons for rejected products, many manufacturers are taking measures to control the humidity to increase their production efficiency and save the cost. In the industries of semi-conductor and electronics, the key section in which the rejected products are most probably to be made is that during the heating process of SMT, the IC(e.g.,PBGA,BGA,or TQFD) is likely to crack and thus cause non-effective welding because of the humidity. Climatest Symor® auto dry cabinet is the best solution to avoid the cracking and non#2;effective welding by dehumidifying the surface of your components. The dry unit can be used for 20 years without replacement,and controller is calibration free within 5 years.We attach dry cabinet application with different humidity range,welcome to download.

Symor Instrument Equipment Co.,Ltd

Maintenance and operation of walk-in temperature humidity test chamber

Technical Library | 2019-11-17 22:46:45.0

Overview of walk-in temperature and humidity chamber: It also belongs to environmental test equipment, it tests whether the product can resist high temperature, low temperature, humidity, or the physical and chemical changes produced under extreme conditions, the walk-in temperature and humidity chamber volume is large, the product is placed, or a large object can be placed, such as automobile, new energy, television and liquid crystal screen, etc. How to do the routine maintenance of the walk-in temperature and humidity chamber: 1. The wet gauze basically, if there is no special case, s/b usually changed once in 3 months 2. The water channel shall be regularly cleaned, including water cup, water tank, etc., so as to prevent the water from being blocked,affect the humidity test. 3. It is forbidden to test the flammable and explosive products inside working room. 4. Clean the chamber on a regular basis 2. How to operate walk-in temperature and humidity chamber: The operation method is same as standard temperature humidity test chamber,the controller is 7-inch LCD programmable color screen, you only need to setthe temperature point---test time--how many cycles need to be tested, This can be done automatically, and the machine will stop automatically when it is complete. If there is any problem during the operation, the corresponding problem point will be displayed on the machine control screen. Walk-in temperature and humidity chamber is a must equipment for reliability test of Automobile,Aerospace,Electronic parts,etc,the operation and maintenance are easy,it is teh tear down mahcine,Climatest engineers will be dispatched to do on-site support,for instance,we will finish commissioning,train customers how to operate,maintain,welcome to follow our company facebook page:https://www.facebook.com/Climatechambers

Symor Instrument Equipment Co.,Ltd

When you pull out the nitrogen pipe of nitrogen cabinet

Technical Library | 2019-11-07 03:07:12.0

Many customers who have purchased the nitrogen cabinets have been in the mistaken belief that the air pipe can be pull down hard,so that it can cause the board to be damaged due to the hard pulling of the air pipe, which leads to the replacement of the penetrating board. Now, the following pictures are provided. Please note: Nitrogen cabinet is a optiomal choice for the microelectronics,semiconductor for humidity proof and anti-oxidation purpose,Climatest has put much efforts on the R&D of dry cabinets,as you know,our advangtage is to handle temperature and humidity,since early 1990s,our engineers began to test and research dry cabinet and nitrogen cabinet,all of our manufacturing process strictly follow ISO9001 standard,we supply to international customers for 20 years,if you are still looking for a reliable dry cabinet manufacturer to protect your MSD from moisture related damage,come to visit www.climatechambers.com,we are ready!

Symor Instrument Equipment Co.,Ltd

Symor ESD storage dry cabinet(Working principle)

Technical Library | 2019-04-08 23:21:29.0

Climatest Symor® adopts molecular sieve to dry air, the whole system is controlled by microcomputer, when humidity is high, It will start to absorb moisture,when the humidity reach the pre-set value, it will stop absorbing, and then discharge the water to outside the cabinet by heating,again and again by automatic control. The most effective and environment-friendly moisture-absorbing desiccant is molecular sieve, molecular sieve is the microporous crystal material synthesized by silicon and aluminium oxide. In order to keep the crystal net discharge to be zero, atoms with cations are located in the crystal structure.and the cation used in these synthetic crystals is usually sodium. At present, there are two kinds of molecular sieves widely used in the dry box industry: Class A and Class X. Molecular sieves are synthesized, shaped and activated under strictly controlled production processes. The whole controlled sythesis process can ensure consistency of the three-dimensional pore size. 3A molecular sieve pore size is 3 angstroms, 4A molecular sieve pore size is 4 angstroms; 13X molecular sieve pore size is 8.5 angstroms. The working principle of molecular sieve: Molecular sieves adsorb molecules onto the crystal surface by physical attraction force. Since 95% surface area of the molecular sieve is within aperture,it needs to screen the adjacent molecules by different size. Only small size molecules can enter into the inner adsorption surface of the molecular sieve through the crystal aperture. This selective adsorption phenomenon is called molecular sieve effect. The molecular sieve adsorption capacity and charge density (polarity) are further related to the adsorbed molecules. The molecular sieves can further distinguish which of the mixed molecules can be adsorbed and determine to what extent the charge density can allow the molecules to be adsorbed onto the crystal. Water molecules are particularly small (2.6 angstroms), that belong to highly polar molecules (very strong positive and negative electron density), and are easily adsorbed by molecular sieves, even under very low moisture condition,once the water molecules are adsorbed,they will be firmly fixed on the crystal. The environment-friendly moisture absorption device is equipped with molecular sieve. When it’s absorbing, the memory alloy controller is in tensile state, and the spring is in contractive state,which just make the valve contact the outer baffle, this insulates the outside air from inside dry box air to achieve dehumidification purpose; and after molecular sieve absorbed moisture inside dry box and become saturated, the program will automatically control the memory alloy device to shrink it so that the valve reaches the inner baffle position. Meanwhile, due to the shrinkage of the memory alloy, the spring is stretched and the valve is pulled out of the outer baffle,so that the moisture in molecular sieve will be discharged into the outside. after the dehumidifying process finished, the program automatically control and reset the memory alloy and spring,to restart absorbing status.

Symor Instrument Equipment Co.,Ltd

How to protect your PCB from moisture related damage?

Technical Library | 2019-04-07 22:47:46.0

How to protect your PCB from moisture related damage? J-STD-033 put forward stricter regulation on the MSD exposure environment,when the exposure time exceed the tolerated,the moisture will penetrate into electronics,Moreover, the newest RoHS regulation will rise soldering temperature,the sudden high temperature will lead to expansion and cracking on electronic components. In order to decrease the moisture defect on PCB for the manufacturers in China,Climatest Symor® begin to concentrated on electronic dry cabinet R&D since early 1990s,we specialize in handling temperature and humidity for 20 years,and we provide best solution for PCB storage.

Symor Instrument Equipment Co.,Ltd

  1 2 Next

humidity control cabinets searches for Companies, Equipment, Machines, Suppliers & Information