Technical Library: measuring (Page 4 of 13)

How to Test a Mass Flow Sensor?

Technical Library | 2021-10-27 02:20:31.0

The mass flow sensor, or air flow sensor is one of the important sensors of the electronic fuel injection engine. It is installed between the air filter and the intake hose to measure the intake volume of the engine cylinder and adjust the fuel ratio according to it. The mass flow sensor converts the inhaled air flow into electrical signals and sends them to the electronic control unit (ECU). As one of the basic signals to determine the fuel injection, it is a sensor that measures the air flow of the suction engine. So if you want to test it, how should you do? Let's start it.

OKmarts Industrial Parts Mall

Stereo Vision Based Automated Solder Ball Height Detection

Technical Library | 2015-04-16 16:11:43.0

Solder ball height inspection is essential to the detection of potential connectivity issues in semi-conductor units. Current ball height inspection tools such as laser profiling, fringe projection and confocal microscopy are expensive, require complicated setup and are slow, which makes them difficult to use in a real-time manufacturing setting. Therefore, a reliable, in-line ball height measurement method is needed for inspecting units undergoing assembly. (...) In this paper, an automatic, stereo vision based, in-line ball height inspection method is presented. The proposed method includes an imaging setup together with a computer vision algorithm for reliable, in-line ball height measurement.

Intel Corporation

New Requirements for SIR Measurement

Technical Library | 2015-02-27 16:46:30.0

During the last period of newly assembled electrical devices (pcbs), new component types like LGA and QFN were also qualified as well as smaller passive components with reliability requirements based on the automotive and industrial industry. In the narrow gaps under components, residues can accumulate more by the capillary forces. This is not that much a surface resistance than an interface issue. Also that the flux residues under such types of components creates interaction with the solder resists from the pcb, as well as the component body was not completely described in the standard SIR measurement. On the other hand also, electrical influence with higher voltage creates new terms and conditions, in particular the combination of power and logic in such devices. The standard SIR measurement cannot analyze those combinations.The paper will discuss the requirements for a measurement process, and will give results. The influences of the pcb and component quality will also be discussed. Furthermore it will describe requirements for nc solder paste to increase the chemical/thermical/electrical reliability for whole devices

Heraeus

Comparing Techniques for Temperature-Dependent Warpage Measurement

Technical Library | 2008-03-13 13:02:50.0

Three full-field optical techniques, shadow moiré, fringe projection and digital image correlation (DIC), are used to measure temperature-dependent warpage for a PBGA package and a PCB component land site from room temperature to 250ºC. The results are qualitatively similar, but imaging resolution and noise properties create offsets between coplanarity values. The paper summarizes strengths and weaknesses for each technique.

Akrometrix

How to inspect the temperature recovering time of thermal shock chamber?

Technical Library | 2019-11-12 02:09:22.0

Thermal shock test chamber can be used for testing the chemical change or physical damage on composite materials caused by the thermal expansion and contraction of the sample in the shortest time,which is subjected to extremely and continuous high and low temperature environment.so how to check the temperature recovery time of this chamber? Normally we take following steps to inspect the temepratuire recovering time: 1.Install the temperature sensor at the specified position, and adjust the temperature controller of hot zone and cold zone to the required nominal temperature respectively. 2.The temperature increases and reduces respectively,30min after temperature in two zones reach stable status,record temperature value of the measuring point,pls set the temperature value of two zones to be required nominal temperature. 3.The temperature shock test chamber automatically places the inspected load into theh ot zone,select the corresponding retention time according to regulated standard. 4.Set the transfer time,then the inspection load is transferred from hot zone to cold zone, and the temperature of the measuring point is observed and recorded, and then the reverse conversion of the load from cold zone to hot zone is carried out according to the same method, and the temperature of the measuring point is observed and recorded. www.climatechambers.com

Symor Instrument Equipment Co.,Ltd

Reliable Young's Modulus Value of High Flexible, Treated Rolled Copper Foils Measured by Resonance Method

Technical Library | 2018-08-15 17:27:28.0

Smartphones and tablets require very high flexibility and severe bending performance ability of the flexible printed circuits (FPCs) to fit into their thinner and smaller body designs. In these FPCs, the extraordinary highly flexible, treated rolled-annealed (RA) copper foils have recently used instead of regular RA foil and electro deposited foils. It is very important to measure the Young's moduli of these foils predicting the mechanical properties of FPCs such as capabilities of fatigue endurance, folding, and so on. Even though the manufacturers use IPC TM-650 2.4.18.3 test method for measuring Young's modulus of copper foils over many years, where Young's modulus is calculated from the stress–strain (S–S) curve, it is quite difficult to obtain the accurate Young's modulus of metal foils by this test method.

JX Nippon Mining & Metals

Using Rheology Measurement As A Potentially Predictive Tool For Solder Paste Transfer Efficiency And Print Volume Consistency

Technical Library | 2020-07-02 13:29:37.0

Industry standards such as J-STD-005 and JIS Z 3284-1994 call for the use of viscosity measurement(s) as a quality assurance test method for solder paste. Almost all solder paste produced and sold use a viscosity range at a single shear rate as part of the pass-fail criteria for shipment and customer acceptance respectively. As had been reported many times, an estimated 80% of the defects associated with the surface mount technology process involve defects created during the printing process. Viscosity at a single shear rate could predict a fatal flaw in the printability of a solder paste sample. However, false positive single shear rate viscosity readings are not unknown.

Alpha Assembly Solutions

Divergence in Test Results Using IPC Standard SIR and Ionic Contamination Measurements

Technical Library | 2017-07-13 16:16:27.0

Controlled humidity and temperature controlled surface insulation resistance (SIR) measurements of flux covered test vehicles, subject to a direct current (D.C.) bias voltage are recognized by a number of global standards organizations as the preferred method to determine if no clean solder paste and wave soldering flux residues are suitable for reliable electronic assemblies. The IPC, Japanese Industry Standard (JIS), Deutsches Institut fur Normung (DIN) and International Electrical Commission (IEC) all have industry reviewed standards using similar variations of this measurement. (...) This study will compare the results from testing two solder pastes using the IPC-J-STD-004B, IPC TM-650 2.6.3.7 surface insulation resistance test, and IPC TM-650 2.3.25 in an attempt to investigate the correlation of ROSE methods as predictors of electronic assembly electrical reliability.

Alpha Assembly Solutions

IST AG - Focus on Flow Sensors

Technical Library | 2017-04-20 19:16:17.0

IST AG thin film mass flow sensors offer solutions for a wide variety of flow applications. The thin film and membrane technologies incorporate highly accurate temperature sensors and heaters as core elements of the sensors. IST AGs flow sensors are applicable in gas (liquids upon request), have an operating temperature range of -30 °C to +450 °C, and can measure low rate and direction from 0.0001 m/s (microflowSens) to 100 m/s (respectively from 1 mL/min to 10 L/min). In addition to measuring flow rates, our sensors can detect the presence of a liquid, biofilm or bubbles as well as indicate liquid level. Development channels guarantee the best possible adaptation of our sensors, whether in terms of dynamic range, response time, directional detection or ambient conditions.

Innovative Sensor Technology, USA Division

Material Effects of Laser Energy When Processing Circuit Board Substrates during Depaneling

Technical Library | 2017-04-27 17:10:16.0

Using modern laser systems for the depanelization of circuit boards can create some challenges for the production engineer when it is compared to traditional mechanical singulation methods. Understanding the effects of the laser energy to the substrate material properly is essential in order to take advantage of the technology without creating unintended side effects. This paper presents an in-depth analysis of the various laser system operating parameters that were performed to determine the resulting substrate material temperature changes. A theoretical model was developed and compared to actual measurements. The investigation includes how the temperature increase resulting from laser energy during depaneling affects the properties of the PCB substrate, which varies from no measurable change to a lowering of the surface resistance of the cut wall depending on the cutting parameters.

LPKF Laser & Electronics