Technical Library: measuring (Page 10 of 13)

A Novel Method for the Fabrication of a High-Density Carbon Nanotube Microelectrode Array

Technical Library | 2016-11-03 17:53:56.0

We present a novel method for fabricating a high-density carbon nanotube microelectrode array (MEA) chip. Vertically aligned carbon nanotubes (VACNTs) were synthesized by microwave plasma-enhanced chemical vapor deposition and thermal chemical vapor deposition. The device was characterized using electrochemical experiments such as cyclic voltammetry, impedance spectroscopy and potential transient measurements. Through-silicon vias (TSVs) were fabricated and partially filled with polycrystalline silicon to allow electrical connection from the high-density electrodes to a stimulator microchip.In response to the demand for higher resolution implants, we have developed a unique process to obtain a high-density electrode array by making the microelectrodes smaller in size and designing new ways of routing the electrodes to current sources.

Hong Kong University of Science

What is the application of moisture proof dry cabinet?

Technical Library | 2019-04-11 05:59:57.0

Are your MSD safely stored? As humidity is found to be one of the key reasons for rejected products, many manufacturers are taking measures to control the humidity to increase their production efficiency and save the cost. In the industries of semi-conductor and electronics, the key section in which the rejected products are most probably to be made is that during the heating process of SMT, the IC(e.g.,PBGA,BGA,or TQFD) is likely to crack and thus cause non-effective welding because of the humidity. Climatest Symor® auto dry cabinet is the best solution to avoid the cracking and non#2;effective welding by dehumidifying the surface of your components. The dry unit can be used for 20 years without replacement,and controller is calibration free within 5 years.We attach dry cabinet application with different humidity range,welcome to download.

Symor Instrument Equipment Co.,Ltd

Critical Evaluation of Laboratory Potentiometric Electronic Tongues for Pharmaceutical Analysis - An Overview

Technical Library | 2019-12-18 23:28:07.0

Electronic tongue systems equipped with cross-sensitive potentiometric sensors have been applied to pharmaceutical analysis, due to the possibility of various applications and developing new formulations. Many studies already proved the complementarity between the electronic tongue and classical analysis such as dissolution tests indicated by Pharmacopeias. However, as a new approach to study pharmaceuticals, electronic tongues lack strict testing protocols and specification limits; therefore, their results can be improperly interpreted and inconsistent with the reference studies. Therefore, all aspects of the development, measurement conditions, data analysis, and interpretation of electronic tongue results were discussed in this overview. The critical evaluation of the effectiveness and reliability of constructed devices may be helpful for a better understanding of electronic tongue systems development and for providing strict testing protocols.

Warsaw University of Technology

Study on the Reliability of Sn–Bi Composite Solder Pastes with Thermosetting Epoxy under Thermal Cycling and Humidity Treatment

Technical Library | 2021-08-25 16:28:36.0

In this study, a Sn–Bi composite solder paste with thermosetting epoxy (TSEP Sn–Bi) was prepared by mixing Sn–Bi solder powder, flux, and epoxy system. The melting characteristics of the Sn–Bi solder alloy and the curing reaction of the epoxy system were measured by differential scanning calorimeter (DSC). A reflow profile was optimized based on the Sn–Bi reflow profile, and the Organic Solderability Preservative (OSP) Cu pad mounted 0603 chip resistor was chosen to reflow soldering and to prepare samples of the corresponding joint. The high temperature and humidity reliability of the solder joints at 85 #14;C/85% RH (Relative Humidity) for 1000 h and the thermal cycle reliability of the solder joints from

Nanjing University

Medical Device Manufacturing: Designing for X-ray Inspection

Technical Library | 2023-11-20 18:18:34.0

When x-ray inspection is used as part of a quality assurance program for any assembled device, steps must be taken early in the design stage to anticipate the use of x-ray inspection later in the development and production processes. This is a lesson that electronic assembly manufacturers learned years ago, and that medical device manufacturers are also discovering. There are several steps involved in learning how to interpret x-ray images, and how to design for x-ray inspection. First, manufacturers need to understand the nature of the x-ray shadow and its modalities; then they need to see how medical device developers and manufacturers are using x-ray inspection; finally, they need to consider taking measures early in the design process to ensure a clear, accurate image when the assembled device undergoes x-ray inspection.

Glenbrook Technologies

PWB Contamination & Reliability DOE

Technical Library | 2023-04-25 22:03:25.0

This report hopes to achieve several goals: 1. Determine the link between bare PWB contamination, soldered assembly contamination and long-term product reliability. 2. Establish measurable limits for bare PWB cleanliness as well as process control limits for both an aqueous as well as a water-soluble soldering process. 3. Determine whether there is any correlation between common, industry-accepted rose/modified rose (omegameter/ionograph type) testing and long term product reliability. 4. Determine the effect PWB plating finish (HASL, Immersion Silver and Cu OSP) has on both bare PWB contamination as well as soldered assembly in a no clean and water soluble process. 5. Determine whether there is a link between percentage of saponifier used to wash soldered assemblies and long-term reliability. 6. Establish a more cost-effective test for manufacturers to use as a process-monitoring tool.

A.T.E. Solutions, Inc.

Microelectronics Reliability: Physics-of-Failure Based Modeling and Lifetime Evaluation

Technical Library | 2024-04-22 20:16:01.0

The solid-state electronics industry faces relentless pressure to improve performance, increase functionality, decrease costs, and reduce design and development time. As a result, device feature sizes are now in the nanometer scale range and design life cycles have decreased to fewer than five years. Until recently, semiconductor device lifetimes could be measured in decades, which was essentially infinite with respect to their required service lives. It was, therefore, not critical to quantify the device lifetimes exactly, or even to understand them completely. For avionics, medical, military, and even telecommunications applications, it was reasonable to assume that all devices would have constant and relatively low failure rates throughout the life of the system; this assumption was built into the design, as well as reliability and safety analysis processes.

NASA Office Of Safety And Mission Assurance

Statistical Aspect on the Measuring of Intermetallic Compound Thickness of Lead Free Solders

Technical Library | 2018-05-17 11:14:52.0

Intermetallic compound (IMC) growth is being studied in earnest in this past decade because of its significant effect the solder joint reliability. It appears that from numerous investigations conducted, excessive growth of IMC could lead to solder joint failure. Leading to this, many attempts has been made to determine the actual IMC thickness. However, precise and true representation of the growth in the actual 3D phenomenon from 2D cross-section investigations has remained unclear. This paper will focus on the measuring the IMC thickness using 3D surface profilometer (Alicona Focus G4). Lead free solder, Sn3.0Ag0.5Cu (SAC305) was soldered onto copper printed circuit board (Cu PCB). The samples were then subjected to thermal cycle (TC) storage process with temperature range from 0 °C to 100 °C for 200 cycles and up to 1000 cycles were completed.

Universiti Kebangsaan Malaysia

Moisture Measurements in PCBs and Impact of Design on Desorption Behaviour

Technical Library | 2018-09-21 10:12:53.0

Moisture accumulates during storage and industry practice recommends specific levels of baking to avoid delamination. This paper will discuss the use of capacitance measurements to follow the absorption and desorption behaviour of moisture. The PCB design used in this work, focused on the issue of baking out moisture trapped between copper planes. The PCB was designed with different densities of plated through holes and drilled holes in external copper planes, with capacitance sensors located on the inner layers. For trapped volumes between copper planes, the distance between holes proved to be critical in affecting the desorption rate. For fully saturated PCBs, the desorption time at elevated temperatures was observed to be in the order of hundreds of hours. Finite difference diffusion modelling was carried out for moisture desorption behaviour for plated through holes and drilled holes in copper planes. A meshed copper plane was also modelled evaluating its effectiveness for assisting moisture removal and decreasing bake times. Results also showed, that in certain circumstances, regions of the PCB under copper planes initially increase in moisture during baking.

National Physical Laboratory

IoT for Real-Time Measurement of High-Throughput Liquid Dispensing in Laboratory Environments

Technical Library | 2020-03-04 23:53:17.0

Critical to maintaining quality control in high-throughput screening is the need for constant monitoring of liquid-dispensing fidelity. Traditional methods involve operator intervention with gravimetric analysis to monitor the gross accuracy of full plate dispenses, visual verification of contents, or dedicated weigh stations on screening platforms that introduce potential bottlenecks and increase the plate-processing cycle time. We present a unique solution using open-source hardware, software, and 3D printing to automate dispenser accuracy determination by providing real-time dispense weight measurements via a network-connected precision balance. This system uses an Arduino microcontroller to connect a precision balance to a local network. By integrating the precision balance as an Internet of Things (IoT) device, it gains the ability to provide real-time gravimetric summaries of dispensing, generate timely alerts when problems are detected, and capture historical dispensing data for future analysis. All collected data can then be accessed via a web interface for reviewing alerts and dispensing information in real time or remotely for timely intervention of dispense errors. The development of this system also leveraged 3D printing to rapidly prototype sensor brackets, mounting solutions, and component enclosures.

SLAS Technology


measuring searches for Companies, Equipment, Machines, Suppliers & Information

SMT feeders

Have you found a solution to REDUCE DISPENSE REWORK? Your answer is here.
Void Free Reflow Soldering

Software for SMT placement & AOI - Free Download.
2024 Eptac IPC Certification Training Schedule

Software programs for SMT placement and AOI Inspection machines from CAD or Gerber.
best pcb reflow oven

Nozzles, Feeders, Spare Parts - Siemens, Fuji, Juki, Yamaha, etc...