Technical Library: paged (Page 1 of 1)

Quick Study Guide to Dummy Components

Technical Library | 2000-11-13 20:48:41.0

Free 16 page reference guide includes lots of pictures. Quickly explains the most important features of SMD components.

TopLine Dummy Components

SMD Nomenclature - in Plain English

Technical Library | 2000-11-13 20:16:17.0

Free 40 page booklet explains about SMD component nomeclature. Lot of drawings. Easy to read. Want to know what 1206 means? Or the difference between a TQFP and LQFP? It's all included.

TopLine Dummy Components

Quick Guide to Daisy Chain

Technical Library | 2000-11-13 20:28:58.0

Free 16 page booklet shows 200 standard SMD Daisy Chain configurations including BGA, QFP, TQFP, TSOP, SOIC, SSOP, Flat Pack, CERQUAD and more.

TopLine Dummy Components

Dummy Components Part Numbering System

Technical Library | 2000-11-13 20:45:03.0

Free 16 page guide quickly explains how to read Dummy Component and test vehicle part numbers. Covers CSP, BGA, QFP, SOIC, Flip Chips, flat packs and discretes and chips.

TopLine Dummy Components

Maintenance Policies and Procedures

Technical Library | 2020-03-08 11:35:53.0

A sample for Larry Bush's Maintenance Policies and Procedures - 2nd Edition (A 415-page book in PDF format. Those who purchase also receive 150 support files in editable format to customize and use as samples and templates.)

Business Industrial Network

Solder Crack Counter Measures

Technical Library | 2023-11-27 18:19:40.0

This page introduces major causes and countermeasures of solder crack in MLCCs (Multilayer Ceramic Chip Capacitors). Major causes of solder cracks Solder cracks on MLCCs developed from severe usage conditions after going on the market and during manufacturing processes such as soldering. Applications and boards that specially require solder crack countermeasures Solder cracks occur mainly because of thermal fatigue due to thermal shock or temperature cycles or the use of lead-free solder, which is hard and fragile.

TDK - Lambda Americas

Serious to make dry oven

Technical Library | 2019-11-13 02:09:44.0

Dry oven is a must instrument almost for every laboratory in different industries,with nearly 20 years efforts and innovation,Climatest now masters core technique of dry oven manufacturing,no matter on temperature uniformity or temperature stability.Behind the quality is 15 years of consistent persistence,strong belief in excellence; from design to R & D to production, from promotion to sales to installation; every step should reach excellence,What you see, you use our products, you choose, you feel that we do our best,this is our faith. Dry Ovens are used to dry or temper electronic components,material tests,torrefaction, wax-melting ,high temperature aging ,preheating and sterilization in industrial and mining enterprises, laboratories and scientific research institutes. .Exterior chamber is made by reinforced steel with painting; working chamber made by anti-corrosion stainless steel SUS#304 .Intelligent PID control, LED controller with over-temperature alarm,timing range within 0~9999min .Hot air circulation system composed of Germany imported low-noisy air blower and optimal air duct which ensure uniform temperature distribution .Double layers of glass door, large transparent window to observe specimen .Forced air convection Climatest manufactures desktop and floor-standing models with RT+10°C-200°C,250°C,300°C,350°C,400°C temperature range,and customized as per special requirement,if you wanna know more details about our dry oven,please visit our product page:https://climatechambers.com/industrial-dry-oven/200-degree-c-hot-air-oven.html

Symor Instrument Equipment Co.,Ltd

Maintenance and operation of walk-in temperature humidity test chamber

Technical Library | 2019-11-17 22:46:45.0

Overview of walk-in temperature and humidity chamber: It also belongs to environmental test equipment, it tests whether the product can resist high temperature, low temperature, humidity, or the physical and chemical changes produced under extreme conditions, the walk-in temperature and humidity chamber volume is large, the product is placed, or a large object can be placed, such as automobile, new energy, television and liquid crystal screen, etc. How to do the routine maintenance of the walk-in temperature and humidity chamber: 1. The wet gauze basically, if there is no special case, s/b usually changed once in 3 months 2. The water channel shall be regularly cleaned, including water cup, water tank, etc., so as to prevent the water from being blocked,affect the humidity test. 3. It is forbidden to test the flammable and explosive products inside working room. 4. Clean the chamber on a regular basis 2. How to operate walk-in temperature and humidity chamber: The operation method is same as standard temperature humidity test chamber,the controller is 7-inch LCD programmable color screen, you only need to setthe temperature point---test time--how many cycles need to be tested, This can be done automatically, and the machine will stop automatically when it is complete. If there is any problem during the operation, the corresponding problem point will be displayed on the machine control screen. Walk-in temperature and humidity chamber is a must equipment for reliability test of Automobile,Aerospace,Electronic parts,etc,the operation and maintenance are easy,it is teh tear down mahcine,Climatest engineers will be dispatched to do on-site support,for instance,we will finish commissioning,train customers how to operate,maintain,welcome to follow our company facebook page:https://www.facebook.com/Climatechambers

Symor Instrument Equipment Co.,Ltd

  1  

paged searches for Companies, Equipment, Machines, Suppliers & Information