Technical Library: problems of aoi (Page 1 of 3)

INTELLI-Pro -- The Future of Automated Optical Inspection

Technical Library | 2022-06-27 17:04:51.0

In today's Electronics Manufacturing Industry, standards for defect and quality control are stricter than ever due to advancements of electronic products and increasing safety and environmental regulations. Electronics Manufacturers are forced to maximize their production efficiency by implementing lean manufacturing initiatives and optimizing production processes. With this in mind, manufacturers are relying upon Automated Optical Inspection (AOI) equipment to streamline the manufacturing process and provide real time root cause analysis of manufacturing defects. The objective is to increase profitability by improving production yields and reducing costly rework.

MIRTEC Corp

Humitector™ Type 2 Non-Reversible Humidity Indicator Cards from Clariant help assure the integrity of moisture-sensitive surface-mount devices

Technical Library | 2021-02-20 00:55:47.0

Customers must be able to rely on accurate humidity indication as an assurance of SMD quality and fitness for processing and use. Without it, they might accept SMDs from suppliers that have already been irreparably damaged by moisture during storage or transit. Or, they might approve for processing SMDs that have been improperly or insufficiently heat-dried. Beyond the processing questions, there are financial questions: Where did the dry pack problems originate and who--supplier, customer, shipper--is financially responsible for the damaged SMDs? In response, Clariant, the originator of the color change humidity indicator card, and a member of the JEDEC's Subcommittee 14.1, "Reliability and Test Methods for Packaged Devices," created a new "non-reversible" halogen and cobalt dichloride free humidity indicator card. This HIC combines two reversible indicators (5% and 10%) with a new non-reversible (60% RH) indicator spot. (Figure 1) The 5% and 10% reversible spots work the way similar indicators do: they change color from blue (dry), to lavender, to pink (wet) to indicate humidity exposure at the indicated levels. If humidity levels drop, they will gradually revert back to blue.

Clariant Cargo & Device Protection

A Machine Vision Based Automatic Optical Inspection System for Measuring Drilling Quality of Printed Circuit Boards

Technical Library | 2024-04-29 21:39:52.0

In this paper, we develop and put into practice an Automatic Optical Inspection (AOI) system based on machine vision to check the holes on a printed circuit board (PCB). We incorporate the hardware and software. For the hardware part, we combine a PC, the three-axis positioning system, a lighting device and CCD cameras. For the software part, we utilize image registration, image segmentation, drill numbering, drill contrast, and defect displays to achieve this system. Results indicated that an accuracy of 5µm could be achieved in errors of the PCB holes allowing comparisons to be made. This is significant in inspecting the missing, the multi-hole and the incorrect location of the holes. However, previous work only focusses on one or other feature of the holes. Our research is able to assess multiple features: missing holes, incorrectly located holes and excessive holes. Equally, our results could be displayed as a bar chart and target plot. This has not been achieved before. These displays help users analyze the causes of errors and immediately correct the problems. Additionally, this AOI system is valuable for checking a large number of holes and finding out the defective ones on a PCB. Meanwhile, we apply a 0.1mm image resolution which is better than others used in industry. We set a detecting standard based on 2mm diameter of circles to diagnose the quality of the holes within 10 seconds.

National Cheng Kung University

Return on Investment of a Pre-Reflow AOI System

Technical Library | 2015-06-30 22:02:41.0

This paper describes the losses from defects at the placement process in the SMT line. Two case studies of European and Taiwanese SMT manufacturers illustrate the actual losses from their defects. An evaluation method to select a pre-reflow AOI system maximizing the return on investment (ROI) is introduced. In the end, ROIs of three commercial pre-reflow AOI systems are compared to demonstrate the importance of selecting an appropriate AOI system. This paper will increase the probability that anyone installing an AOI system during the pre-reflow process will obtain a successful gain with short payback period.

CyberOptics Corporation

Five Myths of Reliability

Technical Library | 2008-12-23 22:32:32.0

Myth 1: I don't worry about design, because most of my problems are with defects from suppliers...

DfR Solutions

Coating Thickness Measurement of Thin Gold and Palladium Coatings on Printed Circuit Boards using X-Ray Fluorescence

Technical Library | 2013-05-30 17:33:26.0

This paper covers the following topics: The Measurement Application, Measurement Requirements, Measurement Problems, Measurement Results, Reference Samples, Conclusions

Fischer Technology, Inc.

Miniaturization of Cooling Solutions

Technical Library | 1999-05-06 11:52:21.0

The market's demand for increasingly powerful products, in smaller and smaller packaging, creates a cooling problem. Integrated circuit (IC) lifetime is dependent upon its operating temperature, creating a trade-off situation: either you enlarge the package to accept additional cooling, or you sacrifice IC lifetime.

Aavid Thermalloy, LLC

Comparing Costs and ROI of AOI and AXI

Technical Library | 2013-08-07 21:52:15.0

PCB architectures have continued their steep trend toward greater complexities and higher component densities. For quality control managers and test technicians, the consequence is significant. Their ability to electrically test these products is compounded with each new generation. Probe access to high density boards loaded with micro BGAs using a conventional in-circuit (bed-of-nails) test system is greatly reduced. The challenges and complexity of creating a comprehensive functional test program have all but assured that functional test will not fill the widening gap. This explains why sales of automated-optical and automated X-ray inspection (AOI and AXI) equipment have dramatically risen...

Teradyne

First Principles of Solder Reflow

Technical Library | 2006-12-18 14:55:35.0

Many solder users have preconceived notions and worries involving reflow profiling guidelines. Year after year of reading profiling recommendations in industry publications, from a litany of pundits, has made it clear that perfect profiles exist and should be sought after. They feel if the solder supplier gives them a tidy drawing on a piece of paper with times and temperatures that it will magically solve all their reflow problems. This is, unfortunately, an often incorrect assumption.

Nordson EFD

The Conditions and Solutions of Lead-free Hand Soldering

Technical Library | 2013-01-05 22:21:01.0

More and more countries legislate to forbib lead usage in solder material. However, the lead-free solder wire has higher melting point and soldering temperature, increase soldering iron temperature may damage the PCB or components. How to solve this problem?

Leisto Industrial Co., Limited

  1 2 3 Next

problems of aoi searches for Companies, Equipment, Machines, Suppliers & Information

Voidless Reflow Soldering

Training online, at your facility, or at one of our worldwide training centers"
Fluid Dispensing Aerospace

High Throughput Reflow Oven
Pillarhouse USA for Selective Soldering Needs

High Resolution Fast Speed Industrial Cameras.