Technical Library: sealed (Page 2 of 3)

Anisotropic Conductive Adhesive Bonding - A High Quality Interconnection Technique

Technical Library | 2011-09-08 13:46:10.0

Anisotropic Conductive Adhesive Bonding is an interconnection technique mostly used for connecting displays to pcb’s using anisotropic conductive adhesive and flex foils. For successful implementation there are a few basic constraints. If these are followed, display connection is a simple and reliable process, giving top quality connections. Heat-Sealing can be done in any factory and can be introduced in a few months, from start of design to mass productions

MIYACHI EUROPE GmbH

Adhesive Bonding Instead Of Welding Or Bolting

Technical Library | 2019-05-01 10:07:37.0

Adhesive bonding involves the use of adhesive to form a material bond between two or more assembly parts. In addition to regular adhesive bonding applications, hybrid processes, in which the adhesive bond includes another function such as sealing or heat dissipation, are gaining importance. Traditional joining methods such as welding or bolting are progressively being replaced in industrial applications by efficient adhesive bonding processes, since these processes provide a number of advantages such as part weight reduction or simplified parts handling.

Scheugenpflug Inc.

How to achieve optimum results in automated dispensing

Technical Library | 2020-02-13 08:41:18.0

Efficient bonding, sealing and potting has a major influence on the sustainable function and safety of electronic components. The key to success here lies in the comprehensive view and control of process engineering. Here it pays to seek collaboration with the systems and the material manufacturer during the very early stages of the project. This is because dispensing systems must be selected for compatibility with the workpiece and the adhesive, sealant or potting compound used. And there are also other factors that play an important role in designing the optimum dispensing system:

Scheugenpflug Inc.

How does IPX9K Rain Test Chamber Works?

Technical Library | 2019-05-08 01:46:32.0

IPX9K Rain Spray Test Chamber(high Pressure high temperature water jet) simulates the use of pressure washer steam cleaning onto the enclosure, It is recognised as the harshest of all ingress protection tests. However the requirement is becoming more prevalent across many industries. Test method for IPX9K : Make sure the water temperature inside the water tank +80°C, water flow rate with 14L-16L per min, water pressure: 8000 Kpa -10000 Kpa (80–100 bar) at distance of 100mm~ 150mm, The test duration is 30 seconds in each of 4 angles, total spray testing time is 2 minutes. IPX9K rain test chamber applicable standards: IEC 60529 – Degrees of protection provided by enclosures (IP Code).Here is working principle in picture. Application: It is mainly suitable for testing the performance of shell and seal of electrical and electronic parts, automobile parts and seals under the condition of dripping rain to prevent Rain Water from permeating or working after drizzling.

Symor Instrument Equipment Co.,Ltd

Moisture and Bubble-Free Material Preparation in Larger Quantities

Technical Library | 2018-09-10 08:44:08.0

Issue: Moisture and bubbles in your dispensing material with larger quantities Solution: Scheugenpflug’s 55-gal Barrel Agitator Station Barrel agitators for casting resins take their technology from the paint sector. They fall short of meeting the special demands of the auto, medical, aeronautics and electronics industries. They can’t guarantee a solid seal on the barrels – often containing expensive, moisture sensitive resins – allowing the humidity of the surrounding environment to damage the material. Also, conventional barrel agitators, as opposed to smaller units, cannot work in a vacuum to process materials directly.

Scheugenpflug Inc.

Using Hansen Space to Optimize Solvent Based Cleaning Processes for Manufacturing Electronic Assemblies.

Technical Library | 2009-07-09 17:23:07.0

Sometimes you just cannot clean with water. Good examples of this are: circuits with batteries attached, cleaning prior to encapsulation, ionic cleanliness testing, and non-sealed or other water sensitive parts. High impedance or high voltage circuits need to be cleaned of flux residues and other soils to maximize performance and reliability and, in these types of circuits; water can be just as detrimental as fluxes. When solvent cleaning is called for, Hansen solubility parameters can help target the best solvent or solvent blend to remove the residue of interest, and prevent degradation of the assembly being manufactured. In short, using this approach can time, manufacturing cost and reduce product liability.

Austin American Technology

Developing An Effective, Fast-Curing, Environmentally Sound Conformal Coating

Technical Library | 2010-02-10 23:50:23.0

The electronics industry has recently undertaken the transition to lead-free processing as a direct consequence of the RoHS directive, which came into force in July 2006. However, this is unlikely to be the last transition required since the European Solvent Emissions Directive, 1999 is starting to be implemented and enforced by national governments. This is resulting in pressure on larger manufacturers, currently emitting more than 5 tonnes of solvent vapour per annum to take steps to limit and reduce their emissions.

Chase Electronic Coatings

Autonomous Driving - New systems to optimally apply potting media

Technical Library | 2019-10-17 08:44:01.0

There has been an increase in sealing and encapsulation applications mainly in the field of autonomous driving. Safety and assistance systems already make driving safer and more comfortable today. With increasing progress even more electronic systems will be added. The smooth functioning of computers, sensors, cameras, etc. - and thus our safety as road users - also depends on optimally applied potting media. These can be applied economically, quickly and with high quality in individual applications and are now mastered. With the changing mobility concepts, however, the prerequisites in manufacturing are changing. The requirements are often not fixed at the outset, but only develop during the course of the project. The aim here is to generate a flexible standard that enables attractive pricing and short delivery times. However, we are prepared for these developments: with our modular system consisting of scalable system modules. From this, individual processes can be taken and combined according to requirements. Our new LiquiPrep systems have recently become part of this modular system. They represent a further development of the proven A310 product family and enable reliable processing and conveying of self-levelling media. In addition to a significantly more intuitive operation, the LiquiPrep systems also offer higher performance thanks to a new, patented membrane pump and an optimized agitator. Image: Optimally applied sealants and casting materials form the basis for high quality and smooth functioning of the components.

Scheugenpflug Inc.

Ingress Protection (IP) test for electronic enclosure test

Technical Library | 2019-04-07 23:34:10.0

Ingress Protection Test Chamber is used to determine the protection degree of product enclosures,the protection level provided by the enclosure is called IP code,our IP test chamber compeletely follow the standard IEC60529 and others. IP protection grade is an important index of electrical equipment safety protection. Protective-grade systems such as ip, which provide a method of classifying products in terms of dust-proof, waterproof and anti-collision levels of electrical equipment and packaging, which have been recognized by most European countries, as drafted by the International Electrotechnical Association (iec (international electro technical commission). And announced in ied529 (bs en 60529 / 1992) outer packing protection grade (ip code). The level of protection is expressed in terms of IP followed by two numbers, which are used to define the level of protection. The first number indicates the extent of the equipment‘s resistance to dust, or the degree to which people are protected from harm in sealed environments. I represents a level that prevents solid foreign matter from entering, with a maximum level of 6; The second number indicates the extent to which the equipment is waterproof. P represents the level of protection against influent and the highest level is 8. Such as the protection level of the motor ip65. Contact electrical equipment protection and external material protection level (first digit) Electrical equipment waterproof protection level (second digit) . IP is the international code used to identify the protection grade ip grade consists of two numbers, the first number for dust, and the second number for waterproof, the larger the number means the better protection level.

Symor Instrument Equipment Co.,Ltd

Previous 1 2 3  

sealed searches for Companies, Equipment, Machines, Suppliers & Information

Void Free Reflow Soldering

High Resolution Fast Speed Industrial Cameras.
Sell Used SMT & Test Equipment

Nozzles, Feeders, Spare Parts - Siemens, Fuji, Juki, Yamaha, etc...
Voidless Reflow Soldering

High Throughput Reflow Oven
PCB Handling with CE

World's Best Reflow Oven Customizable for Unique Applications


"回流焊炉"