Technical Library | 2022-01-19 17:25:29.0
Electrochemical sensors are a class of sensors in which the transducer component is the electrode. These methods are presently utilized in a wide assortment of business applications. These sensors are significant for some factors: the utilization of the electron for signal obtaining, which is known to be a perfect model for logical applications, without squander age; scaling down in versatile gadgets (test microvolume investigation); quick examination; and minimal effort of creation, permitting these techniques to be promoted (for example as business glucose sensors).
Technical Library | 2021-10-27 02:20:31.0
The mass flow sensor, or air flow sensor is one of the important sensors of the electronic fuel injection engine. It is installed between the air filter and the intake hose to measure the intake volume of the engine cylinder and adjust the fuel ratio according to it. The mass flow sensor converts the inhaled air flow into electrical signals and sends them to the electronic control unit (ECU). As one of the basic signals to determine the fuel injection, it is a sensor that measures the air flow of the suction engine. So if you want to test it, how should you do? Let's start it.
Technical Library | 2017-04-20 19:16:17.0
IST AG thin film mass flow sensors offer solutions for a wide variety of flow applications. The thin film and membrane technologies incorporate highly accurate temperature sensors and heaters as core elements of the sensors. IST AGs flow sensors are applicable in gas (liquids upon request), have an operating temperature range of -30 °C to +450 °C, and can measure low rate and direction from 0.0001 m/s (microflowSens) to 100 m/s (respectively from 1 mL/min to 10 L/min). In addition to measuring flow rates, our sensors can detect the presence of a liquid, biofilm or bubbles as well as indicate liquid level. Development channels guarantee the best possible adaptation of our sensors, whether in terms of dynamic range, response time, directional detection or ambient conditions.
Technical Library | 2022-01-18 13:28:16.0
Research Nester published a report titled "LiDAR Sensors Market: Global Demand Analysis & Opportunity Outlook 2031" which delivers detailed overview of theglobalLiDAR sensors market in terms of market segmentation by type, technology, application, and by region.
Technical Library | 2020-10-08 00:55:22.0
This article presents the development of a stretchable sensor network with high signal-to-noise ratio and measurement accuracy for real-time distributed sensing and remote monitoring. The described sensor network was designed as an island-and-serpentine type network comprising a grid of sensor "islands" connected by interconnecting "serpentines." A novel high-yield manufacturing process was developed to fabricate networks on recyclable 4-inch wafers at a low cost. The resulting stretched sensor network has 17 distributed and functionalized sensing nodes with low tolerance and high resolution. The sensor network includes Piezoelectric (PZT), Strain Gauge(SG), and Resistive Temperature Detector (RTD) sensors. The design and development of a flexible frame with signal conditioning, data acquisition, and wireless data transmission electronics for the stretchable sensor network are also presented. The primary purpose of the frame subsystem is to convert sensor signals into meaningful data, which are displayed in real-time for an end-user to view and analyze. The challenges and demonstrated successes in developing this new system are demonstrated, including (a) developing separate signal conditioning circuitry and components for all three sensor types (b) enabling simultaneous sampling for PZT sensors for impact detection and (c)configuration of firmware/software for correct system operation. The network was expanded with an in-house developed automated stretch machine to expand it to cover the desired area. The released and stretched network was laminated into an aerospace composite wing with edge-mount electronics for signal conditioning, processing, power, and wireless communication.
Technical Library | 2023-10-09 15:18:50.0
This technical document provides necessary information and general guidelines for soldering and PCB design for the Würth Elektronik eiSos MEMS sensor products with an LGA surface-mount package
Technical Library | 2017-12-21 11:24:05.0
The present work concerns on the use of sensors to monitor the structural health of wind turbine . Conventionally the inspection was made using non-contact sensing during the turbine’s inoperable period hence loss occurred. A real -time monitoring system via embedded wireless sensor is preferred but the sensor could only be implanted using non-contact printing method due to most turbine blade s’ curved surface. Conductive ink associate d with non-contact printing method via fluid dispensing system are proposed since conductive inks are proven stretchable and fluid dispensing system enables printing on various substrates and works well with any materials...
Technical Library | 2016-10-24 14:59:03.0
Temperature measurement is one of the most important physical parameters when determining quality, accuracy and reliability of processes not only in industrial use, but also in almost all human activities. Temperature sensors are produced with different technologies to fit specific application requirements. IST AG has concentrated one part of the development and manufacturing on high-end thin-film temperature sensors. This know-how is partially derived from the semiconductor industry and allows us to manufacture sensors with high accuracy, excellent long-term stability, high reliability and repeatability within a wide temperature range from -200 °C up to 1000 °C. Because of very small dimensions and low thermal mass, the thin-film temperature sensors exhibit a very short response time.
Technical Library | 2022-01-19 17:50:20.0
pH and oxygen electrochemical sensors were evaluated in a ventilatory hypoxia rabbit model. The ventilator hypoxia protocol included 3 differential phases: basal (100% FiO2), the hypoxia-acidosis period (10% FiO2) and recovery (100% FiO2). Sensors were tested in blood tissue (ex vivo sensing) and in muscular tissue (in vivo sensing). pH electrochemical and oxygen sensors were evaluated on the day of insertion (short-term evaluation) and pH electrochemical sensors were also tested after 5 days of insertion (long-term evaluation). pH and oxygen sensing were registered throughout the ventilatory hypoxia protocol (basal, hypoxia-acidosis, and recovery) and were compared with blood gas metabolites results from carotid artery catheterization (obtained with the EPOC blood analyzer).
Technical Library | 2009-01-21 23:01:49.0
Over the last 10 years, the adoption of wafer-level packaging (WLP) has expanded to a wide range of semiconductor devices applied in a crosssection of industries from Automotive to Mobile Phone, Sensors to Medical Technology.
Industrial Sensor Vision International specializes in advanced camera technology of high resolution fast speed cameras for automation, AOI, 2-D/3-D, SPI inspection and wafer inspection.
3 Morse Road 2A
Oxford, CT USA
Phone: +1 203 592 8723