Technical Library: terry (Page 1 of 1)

Tin Whiskering on PCBA Capacitors in Storage (Inside ESD Bag, Inside a Sealed Cardboard Box)

Technical Library | 2011-01-13 17:37:55.0

The tin whisker failures investigated in this paper were found on functional RoHS-compliant hardware. The samples were not conformal coated. This paper will document the conditions associated with the whisker formation under the following conditions; tin

Foresite Inc.

Comparison of Testing Methods for Residues on Electronic Hardware

Technical Library | 2023-12-26 17:50:54.0

In this white paper, we discuss the pros and cons of five analytical techniques when applied to residue analysis on electronic assemblies. We evaluate the following for their application and limitations for analyzing both visible and invisible residues: FITR, SEM/EDX, XRF, Ion Chromatography, and ROSE

Foresite Inc.

Achieving Large Scale Parallelism Through Operating System Resource Management on the Intel TFLOPS Supercomputer

Technical Library | 1999-05-07 09:58:23.0

From the point of view of an operating system, a computer is managed and optimized in terms of the application programming model and the management of system resources. For the TFLOPS system, the problem is to manage and optimize large scale parallelism. This paper looks at the management in terms of three key topics: memory management, communication, and input/output.

Intel Corporation

Failure Analysis – Using Ion Chromatography And Ion Chromatography/Mass Spec (IC/MS)

Technical Library | 2021-04-29 01:43:34.0

Since the 1980s the electronics industry has utilized ion chromatography (IC) analysis to understand the relationship of ions, and some organics, to product reliability. From component and board fabrication to complete electronic assemblies and their end-use environment, IC analysis has been the de facto method for evaluating ionic cleanliness of electronic hardware.

Foresite Inc.

Understanding Creep Corrosion Field Fails

Technical Library | 2022-03-16 19:48:18.0

Dendrites, Electrochemical Migration (ECM) and parasitic leakage, are usually caused by process related contamination. For example, excess flux, poor handling, extraneous solder, fibers, to name a few. One does not normally relate these fails with environmental causes. However, creep corrosion is a mechanism by which electronic products fail in application, primarily related to sulfur pollution present in the air.1 The sulfur reacts with exposed silver, and to a lesser extent, exposed copper. This paper will explore various aspects of the creep corrosion chemical reaction

Foresite Inc.

How Clean is Clean Enough – At What Level Does Each of The Individual Contaminates Cause Leakage and Corrosion Failures in SIR?

Technical Library | 2016-09-08 16:27:49.0

In this investigation a test matrix was completed utilizing 900 electrodes (small circuit board with parallel copper traces on FR-4 with LPI soldermask at 6, 10 and 50 mil spacing): 12 ionic contaminants were applied in five concentrations to three different spaced electrodes with five replicas each (three different bare copper trace spacing / five replications of each with five levels of ionic concentration). The investigation was to assess the electrical response under controlled heat and humidity conditions of the known applied contamination to electrodes, using the IPC SIR (surface insulation resistance) J-STD 001 limits and determine at what level of contamination and spacing the ionic / organic residue has a failing effect on SIR.

Foresite Inc.

Understanding the Effect of Different Heating Cycles on Post-Soldering Flux Residues and the Impact on Electrical Performance

Technical Library | 2018-11-20 21:33:57.0

There are several industry-accepted methods for determining the reliability of flux residues after assembly. The recommended methods of test sample preparation do not always closely mimic the thermal cycle experienced by an assembly. Therefore, extraction from actual assemblies has become a popular method of process control to assess consistency of post-reflow cleanliness. Every method of post-reflow flux residue characterization will depend on the reflow process followed to prepare the coupon.This investigation will focus on the effect of thermal conditions on the remainder of active ingredients in flux residues after assembly with no-clean solder pastes.

Indium Corporation

Evaluation of No-Clean Flux Residues Remaining After Secondary Process Operations

Technical Library | 2023-04-17 17:05:47.0

In an ideal world, manufacturing devices would work all of the time, however, every company receives customer returns for a variety of reasons. If these returned parts contributed to a fail, most companies will perform failure analysis (FA) on the returned parts to determine the root cause of the failure. Failure can occur for a multitude of reasons, for example: wear out, fatigue, design issues, manufacturing flaw or defect. This information is then used to improve the overall quality of the product and prevent reoccurrence. If no defect is found, it is possible that in fact the product has no defect. On the other hand, the defect could be elusive and the FA techniques insufficient to detect said deficiency. No-clean flux residues can cause intermittent or elusive, hard to find defects. In an attempt to understand the effects of no-clean flux residues from the secondary soldering and cleaning processes, a matrix of varying process and cleaning operation was investigated. Of special interest, traveling flux residues and entrapped residues were examined, as well as localized and batch cleaning processes. Various techniques were employed to test the remaining residues in order to assess their propensity to cause a latent failure. These techniques include Surface Insulation Resistance1 (SIR) testing at 40⁰C/90% RH, 5 VDC bias along with C32 testing and Ion Exchange Chromatography (IC). These techniques facilitate the assessment of the capillary effect the tight spacing these component structures have when flux residues are present. It is expected that dendritic shorting and measurable current leakage will occur, indicating a failing SIR test. However, since the residue resides under the discrete components, there will be no visual evidence of dendritic growth or metal migration.

Foresite Inc.

  1  

terry searches for Companies, Equipment, Machines, Suppliers & Information

SMT feeders

High Precision Fluid Dispensers
One stop service for all SMT and PCB needs

High Throughput Reflow Oven
PCB Handling Machine with CE

World's Best Reflow Oven Customizable for Unique Applications