Technical Library: there's (Page 1 of 1)

Successful ERP Implementation The First Time

Technical Library | 2001-05-23 16:50:56.0

It’s not pretty out there. Companies have spent fortunes on ERP software and implementation only to find that business performance has not improved at all. These large investments and negative ROIs have created a whirlpool of controversy, rampant company politics and even a number of lawsuits. The trade press has reported many negative ERP stories, and even annual reports have pointed the finger at ERP for lower-than-expected earnings. For some, this has created a higher level of fear about making a big ERP mistake...

R. Michael Donovan & Co., Inc.

Component Obsolescence Still Driving the Counterfeit Market

Technical Library | 2013-04-12 07:31:31.0

As change is inevitable, therefore so is obsolescence. In the electronics sector, stocks of components used in subassemblies will eventually run out, no surprise there! However on many occasions, particularly in the often long product life cycles associated with the traditional UK OEM’s in the industrial, military and medical sectors, to name but three, component supply gets ‘difficult’ long before the customers products themselves reach their ‘end of life’. Component manufacturers work to a commercial agenda; when the popularity of a specific device wanes, or indeed when new features are demanded by the market, they will cease production and redeploy their manufacturing capacity to devices that are being demanded by their high volume customers; the global players.

Vigilant Components

Factors determine the price of temperature humidity test chamber

Technical Library | 2019-12-16 22:20:55.0

When we were children,our parents always warn us "Do comparison shopping before you buy",why they say like this?this is a very simple truth, for the first deal,we are always cautious, through continuous comparison in order to find out the best quality, service, after-sale and price. This apply to any industry,there are many manufacturers of environmental test equipment. When some customers inquire a temeprature humidity test chamber, they will find a very common problem. Why is the price of the same equipment quoted by the two manufacturers very different? 1, the chamber body process,which effects the exterior case quality,this price has a gap. 2, the components, esp.components of the refrigeration system, is the core value of the temperature humidity test chamber. 3, even if the body and refrigeration components are the same, some prices are different, that is the manufacturer technical level. 4, regional issues, Wuxi,Changzhou, Dongguan, these brands need to know more. 5. after-sales, a powerful manufacturer often with a sound after-sales service dept.. The above are both technical and service, as well as the delivery cost of goods to the local and overseas are different.

Symor Instrument Equipment Co.,Ltd

Why salt spray chamber fail to spray salt mist?

Technical Library | 2019-11-20 22:44:25.0

Salt spray test chamber is used to test teh salt corrosion resistance ability of hardware, metal and other auto parts,the chamber can quickly detect the corrosion resistance degree of products in the temperature, humidity and salt spraying environment, which can effectively improve production efficiency. So what is the reason why such a salt spray test chamber does not spray? As per our past maintenance experience,there are below reasons,customers can have a look,hope it is helpful: 1, the spray tower is blocked; 2, water pipes clogged, water flow can not go in; 3, the air compressor stops running,pls open the air compressor button; 4, main switch of the air compressor outlet is not turned on,pls turn on. 5, the solenoid valve fails, the pressure meter is broken or the pressure is too low, pls check with Climatest and repair it. 6, when the nozzle is clogged, the nozzle should be carefully removed and cleaned,because it is fragile. 7, if the spray pressure is normal, the position of the nozzle glass is also correct, but what is the reason for not spraying? In this case, it is necessary to carefully observe whether there is dirt at the contact surface of the nozzle. If so, clean up the dirt and the spray can be carried out normally. That‘s all we‘re going to talk about today. If you have any questions, follow us on facebook, Please feel free to ask us questions.

Symor Instrument Equipment Co.,Ltd

  1  

there's searches for Companies, Equipment, Machines, Suppliers & Information

Best SMT Reflow Oven

World's Best Reflow Oven Customizable for Unique Applications
SMT feeders

High Precision Fluid Dispensers
Electronic Solutions

High Throughput Reflow Oven
Circuit Board, PCB Assembly & electronics manufacturing service provider

Software programs for SMT placement and AOI Inspection machines from CAD or Gerber.
design with ease with Win Source obselete parts and supplies

"回流焊炉"