Technical Library | 2011-09-15 18:43:15.0
The revolution in performance driven electronic systems continues to challenge the IC packaging industry. To enable the new generations of processors to reach their performance potential many manufacturers have developed interface formats to enable greater memory bandwidth. To ensure that the memory functions are able to support the increased signal speed, package developers are relying more and more on innovative 3D package assembly techniques and process refinement.
Technical Library | 2018-02-01 00:31:48.0
This paper briefly summarizes the technologies underpinning the evolution in electrical system diagnosis and repair, which include schematic layout automation using prototypes and rule-based styling, instant language translation, 2D/3D view links with schematics, interactive diagnostic procedures, and dynamically-generated signal-tracing diagrams. These technologies empower after-sales service teams with state-of-the-art capabilities, which not only reduce costs but also improve brand quality in the eyes of its customers.
Technical Library | 2016-10-24 15:14:23.0
Biosensors – a new Sensor Type from IST AG What are Biosensors? A biosensor is a device capable of detecting a certain substance or analyte with high specificity. Examples of such analytes are glucose, lactate, glutamine and glutamate. Most biosensors measure the concentration of an analyte in an aqueous solution, usually producing an electrical signal, which is proportional to the analyte’s concentration in its measuring range. An enzymatic biosensor comprises an enzyme, which recognizes and reacts with the target analyte generating a chemical signal, a transducer, which produces a physical signal out of that chemical one, and an electronic amplifier, which conditions and amplifies the signal. Biosensors allow the analysis in complex biological media. The detection of a large number of compounds is of great relevance not only for scientific research but also for process control in the chemical and food industry. It is also indispensable in the health care field for the diagnosis and treatment of diseases and monitoring of illnesses. The pharmaceutical and biotechnology industries greatly desire frequent to continuous analysis of biological media. Such analyses are conducted with the aid of analytical instruments like HPLC systems, which, although robust and reliable, are expensive and have a limited suitability for online operation. For this reason, the acquisition of Jobst Technologies GmbH positions IST AG as a key provider of high-performance and reliable online biosensors.
Technical Library | 2019-08-07 22:56:45.0
The requirement to reconsider traditional soldering methods is becoming more relevant as the demand for bottom terminated components (QFN/BTC) increases. Thermal pads under said components are designed to enhance the thermal and electrical performance of the component and ultimately allow the component to run more efficiently. Additionally, low voiding is important in decreasing the current path of the circuit to maximize high speed and RF performances. The demand to develop smaller, more reliable, packages has seen voiding requirements decrease below 15 percent and in some instances, below 10 percent.Earlier work has demonstrated the use of micro-fluxed solder preforms as a mechanism to reduce voiding. The current work builds upon these results to focus on developing an engineered approach to void reduction in leadless components (QFN) through increasing understanding of how processing parameters and a use of custom designed micro-fluxed preforms interact. Leveraging the use of a micro-fluxed solder preform in conjunction with low voiding solder paste, stencil design, and application knowhow are critical factors in determining voiding in QFN packages. The study presented seeks to understand the vectors that can contribute to voiding such as PCB pad finish, reflow profile, reflow atmosphere, via configuration, and ultimately solder design.A collaboration between three companies consisting of solder materials supplier, a power semiconductor supplier, and an electronic assembly manufacturer worked together for an in-depth study into the effectiveness of solder preforms at reducing voiding under some of the most prevalent bottom terminated components packages. The effects of factors such as thermal pad size, finish on PCB, preform types, stencil design, reflow profile and atmosphere, have been evaluated using lead-free SAC305 low voiding solder paste and micro-fluxed preforms. Design and manufacturing rules developed from this work will be discussed.
Technical Library | 2019-06-26 23:21:49.0
Copper-filled micro-vias are a key technology in high density interconnect (HDI) designs that have enabled increasing miniaturization and densification of printed circuit boards for the next generation of electronic products. Compared with standard plated through holes (PTHs) copper filled vias provide greater design flexibility, improved signal performance, and can potentially help reduce layer count, thus reducing cost. Considering these advantages, there are strong incentives to optimize the via filling process. This paper presents an innovative DC acid copper via fill formulation, for VCP (Vertical Continues Plating) applications which rapidly fills vias while minimizing surface plating.
Technical Library | 2020-04-22 23:50:30.0
Flexible bioelectronics, including wearable and implantable electronics, have revolutionized the way of human-machine interaction due to the fact that they can provide natural and seamless interactions with humans and keep stable and durable at strained states. As sensor elements or biomimetic actuators, flexible bioelectronics can dynamically sense and monitor physiological signals, reveal real-time physical health information and provide timely precise stimulations or treatments. Thus, the flexible bioelectronics are playing increasingly important roles in human-health monitoring and disease treatment, which will significantly change the future of healthcare as well as our relationships with electronics. This review summarizes recent major progress in the development of flexible substrates or encapsulation materials, sensors, circuits and energy-autonomous powers toward digital healthcare monitoring, emphasizing its role in biomedical applications in vivo and problems in practical applications. A future perspective into the challenges and opportunities in emerging flexible bioelectronics designs for the next-generation healthcare monitoring systems is also presented.
Technical Library | 2020-07-08 20:05:59.0
There is a compelling need for functional testing of high-speed input/output signals on circuit boards ranging from 1 gigabit per second (Gbps) to several hundred Gbps. While manufacturing tests such as Automatic Optical Inspection (AOI) and In-Circuit Test (ICT) are useful in identifying catastrophic defects, most high-speed signals require more scrutiny for failure modes that arise due to high-speed conditions, such as jitter. Functional ATE is seldom fast enough to measure high-speed signals and interpret results automatically. Additionally, to measure these adverse effects it is necessary to have the tester connections very close to the unit under test (UUT) as lead wires connecting the instruments can distort the signal. The solution we describe here involves the use of a field programmable gate array (FPGA) to implement the test instrument called a synthetic instrument (SI). SIs can be designed using VHDL or Verilog descriptions and "synthesized" into an FPGA. A variety of general-purpose instruments, such as signal generators, voltmeters, waveform analyzers can thus be synthesized, but the FPGA approach need not be limited to instruments with traditional instrument equivalents. Rather, more complex and peculiar test functions that pertain to high-speed I/O applications, such as bit error rate tests, SerDes tests, even USB 3.0 (running at 5 Gbps) protocol tests can be programmed and synthesized within an FPGA. By using specific-purpose test mechanisms for high-speed I/O the test engineer can reduce test development time. The synthetic instruments as well as the tests themselves can find applications in several UUTs. In some cases, the same test can be reused without any alteration. For example, a USB 3.0 bus is ubiquitous, and a test aimed at fault detection and diagnoses can be used as part of the test of any UUT that uses this bus. Additionally, parts of the test set may be reused for testing another high-speed I/O. It is reasonable to utilize some of the test routines used in a USB 3.0 test, in the development of a USB 3.1 (running at 10 Gbps), even if the latter has substantial differences in protocol. Many of the SI developed for one protocol can be reused as is, while other SIs may need to undergo modifications before reuse. The modifications will likely take less time and effort than starting from scratch. This paper illustrates an example of high-speed I/O testing, generalizes failure modes that are likely to occur in high-speed I/O, and offers a strategy for testing them with SIs within FPGAs. This strategy offers several advantages besides reusability, including tester proximity to the UUT, test modularization, standardization approaching an ATE-agnostic test development process, overcoming physical limitations of general-purpose test instruments, and utilization of specific-purpose test instruments. Additionally, test instrument obsolescence can be overcome by upgrading to ever-faster and larger FPGAs without losing any previously developed design effort. With SIs and tests scalable and upward compatible, the test engineer need not start test development for high-speed I/O from scratch, which will substantially reduce time and effort.
Technical Library | 2020-08-19 19:13:00.0
Commercially available health monitors rely on rigid electronic housing coupled with aggressive adhesives and conductive gels, causing discomfort and inducing skin damage. Also, research-level skin-wearable devices, while excelling in some aspects, fall short as concept-only presentations due to the fundamental challenges of active wireless communication and integration as a single device platform. Here, an all-in-one, wireless, stretchable hybrid electronics with key capabilities for real-time physiological monitoring, automatic detection of signal abnormality via deep-learning, and a long-range wireless connectivity (up to 15 m) is introduced. The strategic integration of thin-film electronic layers with hyperelastic elastomers allows the overall device to adhere and deform naturally with the human body while maintaining the functionalities of the on-board electronics. The stretchable electrodes with optimized structures for intimate skin contact are capable of generating clinical-grade electrocardiograms and accurate analysis of heart and respiratory rates while the motion sensor assesses physical activities. Implementation of convolutional neural networks for real-time physiological classifications demonstrates the feasibility of multifaceted analysis with a high clinical relevance. Finally, in vivo demonstrations with animals and human subjects in various scenarios reveal the versatility of the device as both a health monitor and a viable research tool.
Technical Library | 2019-02-20 16:35:24.0
The High Density Packaging (HDP) User Group has completed a project evaluating the high frequency loss impacts of a variety of imaged core surface treatments (bond enhancement treatments, including chemical bonding and newer low etch alternative oxides) applied just prior to press lamination. Initial high frequency Dk/Df electrical test results did not show a strong correlation with any of the methods utilized within this project to measured surface roughness. The more significant factor affecting the measured loss is the choice of pre-lamination surface treatment. Most of the new chemical treatment systems outperform the older existing systems which depend upon surface roughness techniques to promote adhesion.
1 |