Used SMT Equipment | General Purpose Test & Measurement
0.5 UI calibrated, compliant and integrated jitter injection: RJ, RJ-LF, RJ-HF, PJ1, PJ2, SJ, BUJ, ISI, sinusoidal interference, triangular and arbitrary SSC and residual SSC Excellent signal performance and sensitivity Built-in clock data recovery
Used SMT Equipment | In-Circuit Testers
Agilent-Keysight 83493A Agilent/HP 83493A Single-Mode Clock Recovery Module The 86100 family of wide-bandwidth oscilloscopes offers single connection measurements - no external trigger is required. With the addition of the Agilent 83491/92/93/9
Used SMT Equipment | In-Circuit Testers
Agilent 83496A-100-200-300 Clock Recovery Module The 83496A multi-rate electrical Clock Recovery (CR) module performs clock extraction for waveform analysis with continuous, unbanded tuning from 50 Mb/s to 13.5 Gb/s, ultra-low residual jitter a
Used SMT Equipment | In-Circuit Testers
Agilent-Keysight 83496A-100-200-300 Clock Recovery Module The 83496A multi-rate electrical Clock Recovery (CR) module performs clock extraction for waveform analysis with continuous, unbanded tuning from 50 Mb/s to 13.5 Gb/s, ultra-low residual
Used SMT Equipment | In-Circuit Testers
Agilent-Keysight 83496A-100-200-300 Clock Recovery Module The 83496A multi-rate electrical Clock Recovery (CR) module performs clock extraction for waveform analysis with continuous, unbanded tuning from 50 Mb/s to 13.5 Gb/s, ultra-low residual
Used SMT Equipment | In-Circuit Testers
Advantest D33711 The Advantest D33711 is a Clock Recovery unit. Specifications Clocks: 10 MHz - 3.6 GHz Data And Clock Outputs: 2path ea(input/output) Data Patterns: PRBS,ZSUB,SONET,FLEX Interface: 10 BT and USB Max Datacom Speed: 3.6 GHz
Used SMT Equipment | In-Circuit Testers
Advantest D33711 The Advantest D33711 is a Clock Recovery unit. Specifications Clocks: 10 MHz - 3.6 GHz Data And Clock Outputs: 2path ea(input/output) Data Patterns: PRBS,ZSUB,SONET,FLEX Interface: 10 BT and USB Max Datacom Speed: 3.6 GHz
Used SMT Equipment | In-Circuit Testers
Advantest D33711 The Advantest D33711 is a Clock Recovery unit. Specifications Clocks: 10 MHz - 3.6 GHz Data And Clock Outputs: 2path ea(input/output) Data Patterns: PRBS,ZSUB,SONET,FLEX Interface: 10 BT and USB Max Datacom Speed: 3.6 GHz
Used SMT Equipment | General Purpose Test & Measurement
400,000 Wfms/ second Maximum Waveform Capture Rate Optional Communications Mask Testing Up to 2 .5 Gb/ s Rates Optional Clock Recovery from Serial Data Streams Optional 32-bit Serial Trigger for Isolation of Pattern dependent Effects
Used SMT Equipment | General Purpose Test & Measurement
The 83494A single-mode clock recovery plug-in module is an integrated solution for high-speed digital transmission test. When a separate trigger source is not available, the 83494A can derive a timing reference directly from the signal under test. Th