Electronics Forum | Wed Feb 29 06:33:49 EST 2012 | amitsindwani
Please define the defect in following conditions & link to IPC 610 clause/sub-clause no.: 1. 0603 component placed on 0805 PCB pad 2. 0805 component placed on 0603 PCB pad 3. 1206 component placed on 1210 PCB pad and 4. 1210 component placed on 1206
Electronics Forum | Mon Feb 20 08:25:13 EST 2006 | Rob
No problem. If you get no joy you're going to have to change the footprint to a 1206 or 1210. Murata have a range of high Q value inductors (50-60) & from memory Toko used to be pretty hot too. The terminations on the coilcraft part are listed a
| https://unisoft-cim.com/crosschecking-pcb-component-footprint-and-bom-footprint.html
display needs to be inspected to make sure the component spacing on the PCB assembly ( PCBA ) bare board fits what's listed in the BOM. For example if the part number in the BOM indicates a 1206 component shape then the footprint on the PCB assembly
ASYMTEK Products | Nordson Electronics Solutions | https://www.nordson.com/en/divisions/select/about/news?div=9a65f2aedffb4e329b9911765fe512be&qs=t&page=3
1224 1223 1222 1221 1220 1219 1218 1217 1216 1215 1214 1213 1212 1211 1210 1209 1208 1207 1206 1205 1204 1203 1202 1201 1200 1199 1198 1197 1196 1195 1194 1193 1192 1191 1190 1189 1188 1187 1186 1185
COT specializes in high quality SMT nozzles and consumables for pick and place machines. We provide special engineering design service of custom nozzles for those unique and odd components.