Electronics Forum | Fri Feb 05 20:39:41 EST 2010 | localperm79
I've recently been placed in control of operations of our SCS conformal coat sprayer and I must eliminate problems with wicking of humiseal 1b73 into surface mount connectors while also trying to minimize masking as much as possible. We use a 55:45
Electronics Forum | Wed Feb 10 08:10:26 EST 2010 | davef
Here is a posting by P Kinner at Humiseal ... Typically, there are three main approaches to avoid coating wicking into press-fit connectors (and other keep out areas). Wicking is a phenomenon caused by a combination of low viscosity of conformal coa
Used SMT Equipment | Coating and Encapsulation
2007 Asymtek C740 Conformal Coating Machine, 110VAC and dry shop air required. Inline, L to r Board Flow, SMEMA Last material used: Humiseal 1A33, 1B73, 1B31 Nozzle: SC200HS and a Micro Spray Nozzle. Material Supply Vessel, Operating Manuals and
Industry News | 2013-03-23 04:16:57.0
Drive Technologies offer a large stock of popular HumiSeal coating materials such as 1B31,1B73LED,1R32A2,Thinner 521 at attractive prices.No MOQ restrictions.