Industry Directory | Manufacturer
XPCB is a PCB manufacturer with superior expertise in multilayer rigid-flex PCB and flex PCB, supporting special technology including VIPPO, stacked vias, buried vias, blind vias, unsymmetrical structure, and air gap structure.
Industry Directory | Manufacturer
We are a manufacturer of Reed Switches, SMD Reed Sensors and other customized Magnetic sensing solutions, incorporated in 1971.
Precision Dispensing System for Heated Dispense Applications The GPD Global MAX II is a compact; high-accuracy system designed for today’s advanced heated dispensing applications. The frame is molded from “liquid rock” which gives the system a stabl
A500, A600, A800 - 5, 6 or 8 top/bottom cooling zones. Heating System: Up to eight groups of top and bottom forced hot air convection heating zones. Patented heating plates in each zone uniformly transfer heat to the PCBs using forced hot air co
Electronics Forum | Tue Jun 05 20:25:27 EDT 2001 | davef
Sorry that I'm so late responding. Your new additon probably has 'backee stains on the floor already. Assuming we're talking about a fairly standard board assembly area, you don't need to specify air quality. 1 We specify * Particulate: Level to b
Electronics Forum | Mon May 06 21:40:40 EDT 2013 | davef
ANSI/J-STD-001: * Temperature and Humidity: 18-30°C, 30-70%RH ** If out of range, shall verify electrostatic discharge control program according to ANSI/ESD S20-20 is adequate. ** For process control, more restrictive temperature and humidity limits
Used SMT Equipment | Repair/Rework
Make: Air-Vac Model: Onyx 29 Vintage: 2006 Description: Rework Station Features: Windows XP PC w/Visual Machines Software 1.50.43g Program Development Wizard (Leaded and Lead-Free Master Templates) Board Cooling Option IR Temperature S
Used SMT Equipment | Soldering - Reflow
HEXI, Lead-Free reflow soldering machine, type RFN1020/N, s.n. 0611018, Left to Right, with 10 heating heads plus cooling head, lenght of heating zones 3365mm,max width of PCB 450 mm, width of conveyor 50 to 450 mm, height of conveyor 920 +/_ 20 mm,
Industry News | 2012-02-15 19:18:44.0
GPD Global announces that its PCD4H Dispense Pump yields excellent results with phosphor and non-phosphor-filled LED encapsulation as viewed on the color chart by tightly grouped results.
Industry News | 2003-05-30 08:09:11.0
A new compact package integrates a Hall-effect sensor IC with a back-biasing magnet to achieve high airgap performance and meet restrictive space requirement.
Parts & Supplies | Screen Printers
Name: P1827 MPM air pressure sensor; MPM APS air pressure switch Part Number: P1827 MPM APS sensor Description: P1827 MPM air pressure sensor; MPM APS air pressure switch; MPM APS sensor; Module, Pneum Electric, Pressure Switch Applicable mod
Parts & Supplies | SMT Equipment
Air pressure sensor/switch(P1827) Name: P1827 MPM air pressure sensor; MPM APS air pressure switch Part Number: P1827 MPM APS sensor Description: P1827 MPM air pressure sensor; MPM APS air pressure switch; MPM APS sensor; Module, Pneum Electric,
Technical Library | 2019-12-12 02:43:44.0
Today we discuss the reason that causes temperature humidity chamber to alarm,In most cases, the equipment alarm is caused by the improper operation in the process of use, which mainly includes following reasons:that are refrigeration system, temperature system and circulating system. First, Refrigeration system 1, refrigeration compressor overpressure alarm. If the refrigerant pressure exceeds the set value, it will stop and alarm at the same time. At this time, the fault must be eliminated and then manually reset. 2, short phase power supply, phase sequence alarm. When the external power supply of the equipment is out of phase or the phase sequence is changed, it will stop and alarm at the same time. 3. The circulating cooling water is short of water to alarm. When the water pressure of the cooling circulating water system is insufficient, it will stop and alarm at the same time, and it must wait for the fault to be eliminated and reset at the same time before it could run normally. 4, refrigeration compressor overheating alarm. When the coil of the compressor is overheated and the power supply of the line is not normal, it will stop and alarm at the same time. Second, Temperature system 1, the overtemperature alarm in the chamber. The sensors in the channel and the sample area are equipped with overtemperature protection devices, and there are also overtemperature protecter on the control panel. When the temperature in the working chamber exceeds the setting value on the controller, it will stop and alarm. 2. sample overtemperature protection. When the temperature in the sample area exceeds the protection temperature set by the controller, it will stop and alarm at the same time. The overtemperature protection of the sample is divided into upper limit protection and lower limit protection, which can be set according to the demand, Third,Circulating system 1. The alarm is caused by the overheating of the circulating fan. When the coil of the fan is over-heated, the alarm will be stopped at the same time. 2. The fan over-current alarm. When the current of the fan exceeds the allowable value, the alarm is stopped at the same time, and the normal operation can only be carried out after the fault maintenance of the overcurrent is completed. This is what we talk about today,if you have more questions,let us know.
Technical Library | 2019-05-08 00:04:49.0
It is necessary to know there are some faults that cannot be entirely avoided during the use of temperature and humidity test chamber, but how to deal with them in time is a problem that needs to be paid attention to.Here mainly explain the temperature and humidity test chamber compressor in the reason for the water, and how to deal with it. Reason: water comes from air, because there is always water in the air, known as humidity, which is compressed into supersaturated air and then analyzed to become liquid. The oil comes from the lubrication system of the compressor, possibly because the wear clearance of the mechanism increases, and the lubricating oil will escape into the cylinder. Solution: after the compressor is removed from the temperature and humidity test chamber, with a larger gas storage tank, the oil and water will naturally settle down to the bottom of the jar, and we need to discharge regularly to reduce the oil and water content in the compressed air. Of course, you can also use filters and other things to further reduce the content of oil and water. if you need to know more details about climatic chamber, keep an eye on our website www.climatechambers.com
This elevator format oven utilizes vertical space to accomodate curing applications of up to 4 hours while only occupying 96" (2.5m) of floorspace. Perfect for underfill and encapsulant.
Precision Dispensing System for Heated Dispense Applications The GPD Global MAX II is a compact; high-accuracy system designed for today’s advanced heated dispensing applications. The frame is molded from “liquid rock” which gives the system a stabl
Training Courses | | | PCB Rework and Hand Soldering Courses
The PCB rework and hand soldering courses courses cover techniques of rework and repair of PCBs, BGAs and other electronics assemblies, and teach fundamentals of soldering of electronics assemblies.
Training Courses | | | ESD Control Training Courses
Browse training and certification programs for electrostatic discharge (ESD) control in electronics assembly.
Events Calendar | Wed Oct 20 00:00:00 EDT 2021 - Wed Oct 20 00:00:00 EDT 2021 | ,
Penang Chapter Virtual Vendor & Technical Day
Events Calendar | Mon Jan 29 00:00:00 EST 2024 - Thu Feb 01 00:00:00 EST 2024 | Big Island, Hawaii USA
Pan Pacific Strategic Electronics Symposium
Career Center | sultanpur, U.P. India | Engineering,Sales/Marketing
Experience: • Working with DA Groups -TARA Machines & Tech Services Pvt. Ltd. as a Asst. Manager -Sales. (a) From 4th Feb 2012 to present. • Worked with DVS India Pvt. Ltd. as a Sales & Service Engineer. (a) From 4th June 2010 to 31st
Career Center | , Israel | Engineering,Maintenance,Technical Support
I was born on June , 1972 in Khmelnitsky city , Ukraine . I am male. From 1979 to 1987 I was studying at secondary school #7, having finished which I entered the Technical College of Khmelnitsky in specialty Machine Tools with Computer Numeric Contr
Article Return to Front Page A Low Temperature Alte
Article Return to Front Page A Low Temperature Alte
GPD Global | https://www.gpd-global.com/pdf/doc/Temperature-Monitoring-Camera-Sensor-Guide-22200623.pdf
. The “Forced Air” temperature controller is typically accessed through the dispense system rear panel. • Air pressure setting – forced air heats the substrate positioned above the fixture/lifter device. Hint
| http://etasmt.com:9060/te_news_bulletin/2020-05-04/15961.chtml
Temperature Setting for Each Temperature Zone of SMT Reflow Oven-News-Reflow oven,SMT Reflow Soldering Oven-cmsadmin Home About