Industry Directory | Distributor / Equipment Dealer / Broker / Auctions / Manufacturer / Media / Publisher / Online Resource
All Through-hole & SMT PC Board Assembly equipments,Reflow and wavesoldering equipments,Humiseal conformal coating,SCH Technologies conformal coating equipments,Kyzen Cleaning solutions,Metronelec Solderability tester,Curing oven
Industry Directory | Manufacturer
Sheet metal and machining, Engineering services, prototype design, test fixtures, debug anf functional test fixtures, mating/de-mating fixtures
New Equipment | Assembly Services
S-Bond® solders are unique in their ability to provide a high performance thermal joint between these materials. S-Bond materials offer approximately 10 times the thermal conductivity of most thermal epoxies along with the ability to bond in air with
Includes: 100mm Chuck, Signatone XXC5S/LDC1 Probe Station #XXC5S-NOV, Signatone S-400 Controller, Signatone SA-Zoom, Signatone X/Y Axis Controller XXC5T-NOV, Signatone S-96MW Micropositioner, Kinetic System Vibraplane Table, Ready Lamp ELC-15 Light S
Electronics Forum | Sat Nov 05 07:17:25 EST 2005 | JeffP
That was the case with your oven but it is not so with ours. First, the distance from walls of the inner chamber to the product differs from one oven to another. Second, the dissipation of heat from metal heats up the air in the oven which in turn h
Electronics Forum | Fri Nov 09 19:31:43 EST 2007 | yshiau
Thank you to Dave and Scott!! What I'm delaing with is mass production test for small memory cards in volume! The reason I choose Non-operating temperature cycling is so that I can deal with volume. I can throw in quite a few memory cards in chambe
Used SMT Equipment | General Purpose Equipment
Tenney - Blue M Thermal Shock Chamber For Sale See attached pictures and information below Equipment Information Tenney - Blue M - TPS Model Number: WSP-109 Serial Number: 0801000082 Year: 2007 Type: Hot Cold - Shock
Used SMT Equipment | General Purpose Test & Measurement
Very Nice Thermotron Thermal Shock Chamber For Sale See attached pictures and information below Thermotron Model Number: ATS-320-V-10-705 Serial Number: 44470 Year: 2013 Type: Shock Chamber - Hot/Cold -73 to 177C Hot Zone 60 to 200C 8800
Industry News | 2018-10-18 09:37:27.0
How To Set Profile In SMT Reflow Oven
Industry News | 2020-10-09 22:34:13.0
the benchtop test chamber (also call the small environmental chamber) is quite different from the walk-in test chamber based on its appearance and features. The benchtop test chambers are very suitable for performing both humidity and temperature tests on products and materials to ensure adequate performance and safety. Both the walk-in test chamber and benchtop test chambers serve the same purpose, which is the testing of products and materials capabilities by subjecting it to different temperature conditions for a thorough evaluation. The benchtop test chambers are very portable and small in size, making it easy to perform tests on a small amount of space. As the name sounds, the benchtop test chamber can easily fit on top of a bench or table.
Technical Library | 2019-11-12 02:09:22.0
Thermal shock test chamber can be used for testing the chemical change or physical damage on composite materials caused by the thermal expansion and contraction of the sample in the shortest time,which is subjected to extremely and continuous high and low temperature environment.so how to check the temperature recovery time of this chamber? Normally we take following steps to inspect the temepratuire recovering time: 1.Install the temperature sensor at the specified position, and adjust the temperature controller of hot zone and cold zone to the required nominal temperature respectively. 2.The temperature increases and reduces respectively,30min after temperature in two zones reach stable status,record temperature value of the measuring point,pls set the temperature value of two zones to be required nominal temperature. 3.The temperature shock test chamber automatically places the inspected load into theh ot zone,select the corresponding retention time according to regulated standard. 4.Set the transfer time,then the inspection load is transferred from hot zone to cold zone, and the temperature of the measuring point is observed and recorded, and then the reverse conversion of the load from cold zone to hot zone is carried out according to the same method, and the temperature of the measuring point is observed and recorded. www.climatechambers.com
SMTnet Express, May 9, 2019, Subscribers: 31,902, Companies: 10,760, Users: 26,083 Cold Ball Pull Test Efficiency for the PCB Pad Cratering Validation with the Ultra Low Loss Dielectric Material Credits: iNEMI (International Electronics
Heller Industries Inc. | https://hellerindustries.com/wp-content/uploads/2018/07/flux.pdf
face while inspecting or replacing filters. AIR OVEN FLUX COLLECTION SYSTEM WITH SINGLE EXHAUST FLUX COLLECTION CLEANOUT CHAMBERS WASTE COOLING AIR 225 CFM MAXIMUM 350 CFM EXHAUST COLD AIR BLOWER REFLOW 1 COOLING 2 COOLING BLOWERS COLD AIR INSULATED HOSE
| https://www.eptac.com/wp-content/uploads/2015/03/ecss_q_st_70_18c-space-product-assurance-rf-coax-cables.pdf
or cold chambers capable of maintaining temperatures between ‐50 °C and +90 °C NOTE Under certain circumstances (see Table 5‐2 step 3.3) greater temperature extremes can be required. b. The supplier shall calibrate the working zone to