Industry Directory | Manufacturer
TennMax Inc is EMI and Thermal Management Specialist. We offer total solutions for any EMI and thermal applicatons.
JMC Products is a leading manufacturer of thermal solutions with facilities around the world. Our product line features AC and DC fans, heatsinks, special thermal products, and cooling solutions for all AMD and Intel processors.
New Equipment | Board Handling - Conveyors
Model No: KSUN 460F Cooling Conveyor Power supply: 100-230V AC (customized), single phase Power load: MAX 100V/A Transport direction: Left to right/right to left(optional) Transport height: 900±20mm (or customized) PCB thickness: Min 0.6mm PC
A500, A600, A800 - 5, 6 or 8 top/bottom cooling zones. Heating System: Up to eight groups of top and bottom forced hot air convection heating zones. Patented heating plates in each zone uniformly transfer heat to the PCBs using forced hot air co
Electronics Forum | Wed Jan 11 15:21:51 EST 2012 | pr
Can anyone recommend fans to put on the conveyors post reflow? Thank you, PR
Electronics Forum | Wed Jan 11 16:30:02 EST 2012 | davef
ESD Control Products * desco.com * esdproduct.com * correctproducts.com * esdsystems.com * staticsolutions.com
Used SMT Equipment | Soldering - Reflow
10 Heat Zones Voltage: 220V Max PCB size: 18" Feed Direction: L-R Additional Options: EHC, Fan Speed control, Cool Pipe
Used SMT Equipment | Soldering - Reflow
10 Heat Zones Voltage: 380V Max PCB size: 18" Feed Direction: L-R Additional Options: EHC, Dual Lane (MFFM), Fan Speed Control, CBS, Reactor, Cool Pipe
Industry News | 2015-09-14 17:15:45.0
ISVI Corp. has announced the official release of its all-new IC-M29S-CL, a monochrome 29 Megapixel CCD camera with a base configuration Camera Link interface achieving 4.45fps.
Industry News | 2018-02-02 18:44:38.0
The IWLPC Technical Committee is pleased to announce the Best of Conference, Best Presentation & Best Papers in WLP, 3D, Advanced Manufacturing and Test tracks as chosen by the technical committee and attendees based on technical merit, relevance, originality, knowledge of subject, quality of material, and quality of presentation.
Parts & Supplies | Assembly Accessories
Panasonic N610029094AB CM402 CM602 Vacuum pump cooling and cooling fan
Parts & Supplies | Assembly Accessories
AXPC fan Assembly 949839603998 0.8M Linking Conveyor, Single Lane, for Cooling, with 6 Fan on Top MMLC-2103.8F 0.8m Linking Conveyor, without Fan MMLC-2103.8 1KURA FAN (for Samsung Reflow SRF70i82 ) U6250MKG1 1M Conveyor With
Technical Library | 1999-05-06 11:42:16.0
The most reliable and well-designed electronic device can malfunction or fail if it overheats. Considering thermal issues early in the design process results in a thermally conscious system layout and minimizes costs through the use of passive cooling and off-the-shelf components. When thermal issues are left until completion of the design, the only remaining solution may be a costly custom heat sink that requires all the space available. Incorporating a heat sink or a fan into a product after it is fully developed can be expensive, and still may not provide sufficient cooling of the device.
Technical Library | 2019-12-12 02:43:44.0
Today we discuss the reason that causes temperature humidity chamber to alarm,In most cases, the equipment alarm is caused by the improper operation in the process of use, which mainly includes following reasons:that are refrigeration system, temperature system and circulating system. First, Refrigeration system 1, refrigeration compressor overpressure alarm. If the refrigerant pressure exceeds the set value, it will stop and alarm at the same time. At this time, the fault must be eliminated and then manually reset. 2, short phase power supply, phase sequence alarm. When the external power supply of the equipment is out of phase or the phase sequence is changed, it will stop and alarm at the same time. 3. The circulating cooling water is short of water to alarm. When the water pressure of the cooling circulating water system is insufficient, it will stop and alarm at the same time, and it must wait for the fault to be eliminated and reset at the same time before it could run normally. 4, refrigeration compressor overheating alarm. When the coil of the compressor is overheated and the power supply of the line is not normal, it will stop and alarm at the same time. Second, Temperature system 1, the overtemperature alarm in the chamber. The sensors in the channel and the sample area are equipped with overtemperature protection devices, and there are also overtemperature protecter on the control panel. When the temperature in the working chamber exceeds the setting value on the controller, it will stop and alarm. 2. sample overtemperature protection. When the temperature in the sample area exceeds the protection temperature set by the controller, it will stop and alarm at the same time. The overtemperature protection of the sample is divided into upper limit protection and lower limit protection, which can be set according to the demand, Third,Circulating system 1. The alarm is caused by the overheating of the circulating fan. When the coil of the fan is over-heated, the alarm will be stopped at the same time. 2. The fan over-current alarm. When the current of the fan exceeds the allowable value, the alarm is stopped at the same time, and the normal operation can only be carried out after the fault maintenance of the overcurrent is completed. This is what we talk about today,if you have more questions,let us know.
A500, A600, A800 - 5, 6 or 8 top/bottom cooling zones. Heating System: Up to eight groups of top and bottom forced hot air convection heating zones. Patented heating plates in each zone uniformly transfer heat to the PCBs using forced hot air co
PCB reject conveyor/AOI rework conveyor/NG PCB conveyor/NG reject conveyor, link:https://www.ascen.ltd/Products/Automatic_SMT_equipment/PCB_conveyor/130.html PCB reject conveyor is designed for good/bad PCB separation. It can also be used when visua
| http://etasmt.com/cc?ID=te_news_news,26165&url=_print
) - Buzzer - Manual width adjustment Double plate structure SMEMA interface - Controlled by PLC Cooling fans (120pi_ _2X2) OPTIONS Digital speed controller - Auto width adjustment - Double sensors - ESD powder coating
1st Place Machinery Inc. | http://www.firstplacemachinery.com/first_place_smt_pcb_conveyors_pct.html
PCT Exit PCT Exit Wave Solder Conveyors 6 Units available With Cooling Fans to Cool PCBs Very Good Condition Location: Dracut, MA Price: $2,000 each Wave Solder Exit Conveyor See more photos below