Lead Tinning is an important aspect when components need to withstand adverse conditions for extended periods. Lead Tinning can also be used in the restoration of corroded components to their original condition. V-TEK meets or exceeds Mil standards.
Methods in accordance with PRO-STD-001, SAE AS 5553, and SAE AS 6081. Process follows ISO/DIS 12931. Datest tools and training are used to detect packaging damage; ESD compliance violations; falsified or altered documentation; tampered part markin
Electronics Forum | Thu Jan 05 12:06:12 EST 2006 | Rob
It wasn't corroding the stencil, it was corroding the cleaning fluid system.
Electronics Forum | Thu Aug 17 08:38:21 EDT 2006 | pjc
Any materials that come in contact with the flux should be made from stainless steel, titanium, or plastics. These materials will not corrode from OA fluxes. Overspray is an issue. I think Pillerhouse has that jet fluxer, so I don�t think there is mu
Industry News | 2011-05-06 21:39:30.0
Kyzen announces that Phil Zhang, its China Sales Manager, will present twice during the upcoming SMTA China East conference, which is being held in conjunction with NEPCON China 2011.
Industry News | 2015-04-07 17:14:44.0
KYZEN announces that David Lober presented during the recent SMTA Intermountain Expo at Boise State University. Mr. Lober presented “Improving Device Reliability When Building Highly Dense Assemblies.” For more than 25 years KYZEN consistently has delivered leading science connected to care in order to persistently create the most effective cleaning solutions for each customer’s unique manufacturing process or problem. Mr. Lober is part of KYZEN’s innovative new product technology team.
Technical Library | 2015-07-16 17:24:23.0
Qualification of electronic hardware from a corrosion resistance standpoint has traditionally relied on stressing the hardware in a variety of environments. Before the development of tests based on mixed flowing gas (MFG), hardware was typically exposed to temperature-humidity cycling. In the pre-1980s era, component feature sizes were relatively large. Corrosion, while it did occur, did not in general degrade reliability. There were rare instances of the data center environments releasing corrosive gases and corroding hardware. One that got a lot of publicity was the corrosion by sulfur-bearing gases given off by data center carpeting. More often, corrosion was due to corrosive flux residues left on as-manufactured printed circuit boards (PCBs) that led to ion migration induced electrical shorting. Ion migration induced failures also occurred inside the PCBs due to poor laminate quality and moisture trapped in the laminate layers.
Technical Library | 2016-11-10 17:37:35.0
The demand for compute capability is growing rapidly fueling the ever rising consumption of power by data centers the worldwide. This growth in power consumption presents a challenge to data center total cost of ownership. Free-air cooling is one of the industrial trends in reducing power consumption, the power usage effectiveness (PUE) ratio, and the total cost of ownership (TCO). Free-air cooling is a viable approach in many parts of the world where the air is reasonably clean. In Eastern China, the poor quality of air, high in particle and gaseous contamination, is a major obstacle to free-air cooling. Servers exposed to outside air blowing in to data centers will corrode and fail at high rate. The poor reliability of hardware increase TCO dramatically. This paper describes a corrosion resistant server design suitable for reliable operation in a free-air cooling data center located in Eastern China where the indoor air quality can be as poor as ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers) severity level G3. An accelerated corrosion test method of verifying hardware reliability in the ASHRAE severity level G3 environment is also described.
Events Calendar | Tue Feb 18 00:00:00 EST 2020 - Tue Feb 18 00:00:00 EST 2020 | ,
Corrosion Testing For Electronic Equipment
Heller Industries Inc. | https://hellerindustries.com/searchqueries/
soldering reflow circuit board reflow cold solder joints reflow company reflow cooling rate reflow corroded solder joints reflow dom reflow double sided chip reflow electronics reflow epoxy reflow
| https://ipcapexexpo.org/exhibitors/contract-general-rules-regulations
. Caps and plugs. Caps and plugs required on containers and cylinders when not in use. Leaks, damage or corrosion. Leaking, damaged or corroded compressed gas containers, cylinders and tanks shall be removed from service by approved qualified persons