Electronics Forum: corrosion enig (30)

nickel corrosion

Electronics Forum | Thu Jul 15 06:27:50 EDT 2010 | xps

Hi after an enviromental test 85C/85RH, for 3 months (powered), of an electronic assembly with edge finger tabs ENIG finished (nickel 5micron, gold 0.02micron), the nickel disappears completely under the gold (due to corrosion, I think). Does anyone

PCB pads corrosion

Electronics Forum | Mon Jan 04 22:09:57 EST 2016 | a290668789

It's amazing. I rarely saw that ENIG finish could be corroded. It should be the Nickel corroded issue and then affected the solderability. Not clear how to clear this, if you get the answer, let me know. good luck

Industry News: corrosion enig (5)

Solder Tinned Pads vs Gold Plated Pads - The Importance of Selecting the Proper Surface Finish

Industry News | 2018-10-18 10:16:53.0

Solder Tinned Pads vs Gold Plated Pads - The Importance of Selecting the Proper Surface Finish

Flason Electronic Co.,limited

Technic Releases Black Pad Resistant Electroless Nickel

Industry News | 2012-01-03 10:40:18.0

Technic has announced the release of Technic EN AT5600, an electroless nickel developed specifically to eliminate black pad and to improve soldering on ENIG coated PCBs. Technic EN AT 5600 is the first electroless nickel that provides lateral growth on copper, yielding a flatter surface with less pronounced grain boundaries instead of the typical nodular, "cauliflower-like" structure from older formulas.

Technic Inc.

Technical Library: corrosion enig (8)

Eliminating Ni Corrosion in ENIG/ENEPIG Using Reduction-Assisted Immersion Gold in Place of Standard Immersion Gold

Technical Library | 2023-01-10 20:08:36.0

Nickel corrosion in ENIG and ENEPIG is occasionally reported; when encountered at assembly it manifests as soldering failures in ENIG and wire bond lifts in ENEPIG. Although not common, it can be highly disruptive, resulting in missed deliver schedules, supply chain disruption, failure analysis investigations, and liability - all very costly.

Uyemura International Corporation

EFFECTS OF ENIG NICKEL CORROSION ON WETTING BALANCE TEST RESULTS AND INTERMETALLIC FORMATION

Technical Library | 2023-01-10 20:03:37.0

Since the IPC-4552 rev A for ENIG was introduced there have been many requests for clarification of acceptable and unacceptable levels of nickel corrosion. This paper attempts to further clarify the effects of nickel corrosion on solder wetting balance test results and the resultant intermetallic formed. The study will attempt to produce level 1, level 2, and level 3 corrosion as denoted by IPC-4552 rev A and tabulate wetting balance results and congruity of intermetallic formed.

Uyemura International Corporation

Express Newsletter: corrosion enig (83)

Corrosion Resistance of Different PCB Surface Finishes in Harsh Environments

Corrosion Resistance of Different PCB Surface Finishes in Harsh Environments SMTnet Express August 9, 2012, Subscribers: 25369, Members: Companies: 8949, Users: 33450 Corrosion Resistance of Different PCB Surface Finishes in Harsh Environments

Partner Websites: corrosion enig (9)

Beyond the Surface: A Peek into How PCBs Are Made

Imagineering, Inc. | https://www.pcbnet.com/blog/how-pcbs-are-made/

. Common types of surface finishes are: HASL (Hot Air Solder Leveling): A cost-effective finish that enhances solderability and protects copper. ENIG

Imagineering, Inc.


corrosion enig searches for Companies, Equipment, Machines, Suppliers & Information

Sm t t t t t t t t t t net
  1 2 3 4 5 6 7 8 9 10 Next
SMT Machines

High Precision Fluid Dispensers
2024 Eptac IPC Certification Training Schedule

High Throughput Reflow Oven
SMT feeders

World's Best Reflow Oven Customizable for Unique Applications
Fully Automatic BGA Rework Station

Internet marketing services for manufacturing companies