634 dek 265 horizon servo following error camera results

Electronics Forum: dek 265 horizon servo following error camera (10)

DEK 265 Horizon Servo Following Error

Electronics Forum | Thu Jan 04 11:07:59 EST 2018 | ilavu

Ray, Did you solve this problem? I am having same error on same model machine. My problem is, when camera axis moves to look at the first fiducial, camera hits to the cleaner and error comes up with rising table error, camera axis not home. Even log

DEK 265 Horizon Servo Following Error

Electronics Forum | Fri Jan 05 12:02:28 EST 2018 | ilavu

Camera works fine from home to ref. position to fiducial1 and 2. Problem shows up from home to board stop. AC voltage between AC1 and AC2 is 41.7 and during move it drops to 41.5.

Express Newsletter: dek 265 horizon servo following error camera (624)


dek 265 horizon servo following error camera searches for Companies, Equipment, Machines, Suppliers & Information

Sm t t t t t t t t t t net