Electronics Forum | Thu Feb 17 15:01:23 EST 2005 | davef
We're not familiar with your DYMAX #984-LVUF. The problem is not with your conformal coating. The problem is with your 0805 [and not all of 0805, probably just those from a specific supplier]. This lack of coverage of components is called dewetting
Electronics Forum | Thu Mar 31 10:14:06 EST 2005 | davef
There's some nice low-VOC uV coatings out there. We don�t use uV cured coatings, but try: * http://www.emersoncuming.com * http://www.dymax.com * http://www.mgchemicals.com * http://www.loctite.com * http://www.humiseal.com Be aware that uV co
SMTnet Express, April 2, 2015, Subscribers: 22,572, Members: Companies: 14,281, Users: 37,997 Guide to Light-Cure Conformal Coating Dymax Corporation Each year the electronics industry is faced with new product designs that call for smaller