Electronics Forum | Wed Jan 24 22:38:45 EST 2007 | electrovert
Hello, My first time post up here. I have a problem with thermo runaway on upper zone #5 on the Omni 10 Electrovert. We changed the thermocouple #5 but the problem came back up. We swapped Sensoray board 8 and 9, swapped board #3 (T/C interface boar
Electronics Forum | Thu Jan 25 15:39:07 EST 2007 | electrovert
We swapped the solid state relay for zone 5 bottom to zone 5 top but the problem came up once a while. As for noise protection, there are jumpers at E1 to E8 and E9 to E16. They are hardware filters and prevent noise spikes from affecting thermocoupl
Used SMT Equipment | Conveyors
Speedlines Camalot1818 Underfill Agilent SJ 50 AOI Universal GSM PTF Panasonic FCB-2M Flip Chip Bonder Speedlines MPM accuflex Solder Paste Printer DEK 265 GSX Solder Paste Printing Autolink Engineering PTE LTD R4200 Offl
Parts & Supplies | Board Cleaners
Baldor Motor 10HP 215TC, CEM3711T with Sonic Air Systems Sonic 70, 460VAC 3 phase power. Removed in working order from an Electrovert Aquastorm 200 Inline Water Wash Machine with a Sonic Air Systems Model Sonic 70 - see pictures for specifications
Career Center | Fort Worth, Texas USA | Engineering,Maintenance,Production,Quality Control,Research and Development
A mechanically-inclined, results-oriented, lean-driven professional with proven success in implementing programs that result in efficiencies and cost savings. Effectively communicates with diverse audiences, encourages training and employee developme
Heller Industries Inc. | https://hellerindustries.com/wp-content/uploads/2018/06/688951_OvenSetupWizard-XP4021.pdf
. HC2 Global High Process: 450C (default). For HC2 controller this is a global high process alarm in case of temperature runaway and channel high process is turned off. HC2 Alerts on Comm. Loss