Electronics Forum | Sat May 29 14:03:18 EDT 2010 | padawanlinuxero
Hello guys! I have a problem I had to change the MI Board on a MYDATA TP9-4 machine because it was firing 3 or more feeders at the same time, after the change it run great but then for some reason after a while it start to show an error message that
Electronics Forum | Mon Aug 05 09:39:07 EDT 2019 | filipblad
Hi, I'm getting the F-MOT-MOVE X/156 error on our MY12 pick'n place. The manual tells me its an hardware issue. I found another thread on here where someone had a similar issue and they found out it was a power subbly issue. If I open the service pro
| https://unisoft-cim.com/pcbtest.php
; *Cap C1 10u 20 20 f P/N 3H100M-CR-1; *Ind L1 33u 10 10 10 f P/N 3XCTX3-32-P; *Res R12 10k 1 1 f P/N 3XBT10-02-F; *Devices BATT1 1.UN002137 2.GND 5.UN002137 6.GND; C1 1.+5VB 2.GND; *XY C6 1 X 2.200 Y 2.750 C6 2 X 2.200 Y 2.850 Ref Des Pin_Name PadLocX PadLocY Side PadSizeX PadSizeY NetName JP1 6
GPD Global | https://www.gpd-global.com/co_website/pdf/doc/FLOwareGEMInterface_1.2.0.pdf
, events that prompt a change of state, and the composition of states. The symbols are then listed and explained. See the figure below for the basic notational symbols. H* S C a) State b) Transition c) Default Entry Point d) History e) Selector f