Electronics Forum: f-mot-setdyn (4)

MYDATA MY15E F-MOT-SETDYN Z/3: Upper end point outside limit

Electronics Forum | Fri Oct 12 11:16:46 EDT 2018 | tech1

Sounds like one of the Z stops is not functioning or needs to be adjusted.

MYDATA MY15E F-MOT-SETDYN Z/3: Upper end point outside limit

Electronics Forum | Thu Oct 11 00:11:49 EDT 2018 | mk15

I am looking for some help for where to look to fix this MY15E problem. We started the machine after the weekend and this error code comes. F-MOT-MSETDYN z/3: Upper end point outside limit. Any suggestions? Thanks