Electronics Forum | Wed Feb 10 08:10:26 EST 2010 | davef
Here is a posting by P Kinner at Humiseal ... Typically, there are three main approaches to avoid coating wicking into press-fit connectors (and other keep out areas). Wicking is a phenomenon caused by a combination of low viscosity of conformal coa
Electronics Forum | Wed Nov 09 09:27:44 EST 2011 | edmaya33
If you are using a Humiseal. try UV-40 gel which is about 20Kcps. it will dam your material from capillary flow. It should be applied prior to coating of your low viscous material.