New SMT Equipment: hydra z failure (39)

Nozzles Automatic Cleaning Device Conformal Coating Machine with Coating scope L580*W580mm

Nozzles Automatic Cleaning Device Conformal Coating Machine with Coating scope L580*W580mm

New Equipment | Coating Equipment

Nozzles Automatic Cleaning Device Conformal Coating Machine  with Coating Scope L580*W580mm   Technical parameter Model CWCC-3.3L External Size L*W *H 1010*1360*1675mm(L*W*H) Weig

ChuangWei Electronic Equipment Manufactory Ltd.

PCBA Conformal Coating Machine with 0.02mm Precision Double Nozzle

PCBA Conformal Coating Machine with 0.02mm Precision Double Nozzle

New Equipment | Coating Equipment

Conformal Coating Machine Application: PCBA surface coating, dam process, coating solder mask, DIP components fixing. Conformal Coating Machine Technical Parameter Model CWCC-3L External Size L*W *

ChuangWei Electronic Equipment Manufactory Ltd.

Electronics Forum: hydra z failure (84)

Mydata TP11 UFP hardware initiation failure

Electronics Forum | Thu Jul 20 07:40:56 EDT 2006 | ev

I have a TP11 UFP without the hydra option and have had difficulty keeping it running. The latest problem is a hardware iniation problem which in the past was a PAIB board failure which I replaced about one year ago almost to the day. Has anyone seen

Mydata TP11 UFP hardware initiation failure

Electronics Forum | Thu Jul 20 10:48:43 EDT 2006 | pms

Ev, This error could be caused by any number of problems. Is there an error message in the message window before hardware initiation error? If so, what is it? A failure in any axis (x,y,z,c,theta,y-wagon,tray-wagon) could cause your symptom. Paul

Used SMT Equipment: hydra z failure (69)

Mydata MY100Sxe-14

Mydata MY100Sxe-14

Used SMT Equipment | Pick and Place/Feeders

Software: 2.9.x T3 Linear Table Electrical Two-Pole Test Electrical Transistor Test Optical Centering Conveyor Shared Databases Hydra Z High Speed Hydra High Speed Autoteach Linescan for Z Line Mode Fast Place Sequence

Baja Bid

Mydata MY12

Mydata MY12

Used SMT Equipment | Pick and Place/Feeders

2004 Mydata MY 12 SMT Pick and Place Power: 210 / 121VAC; 3 Phase Machine Dimensions: 132" x 48" x 60" Features: Electrical two-pole test Optical Centering HYDRA; HYDRA High Speed Z High Speed; Autoteach Line Scan Software Version 2.4.6b

Baja Bid

Industry News: hydra z failure (29)

Ascentech LLC Announces Aprotec Z-Check 3D Benchtop SPI Measurement Systems

Industry News | 2013-04-15 15:16:28.0

Ascentech LLC, North American Distributor for UK-based Aprotec Instrumentation, announces the availability of the Aprotec Z-Check family of solder paste inspection and measurement systems. Z-Check systems are easy-to-use benchtop non-contact SPI measuring systems capable of meeting the needs of today's demanding PCB production and assembly environment.

Ascentech LLC

Ascentech LLC Announces Aprotec Z-Check 3D Benchtop SPI Measurement Systems

Industry News | 2013-06-27 08:49:03.0

Chester, Connecticut, USA – Ascentech LLC, North American Distributor for UK-based Aprotec Instrumentation, announces the availability of the Aprotec Z-Check family of solder paste inspection and measurement systems. Z-Check systems are easy-to-use benchtop non-contact SPI measuring systems capable of meeting the needs of today’s demanding PCB production and assembly environment.

Ascentech LLC

Parts & Supplies: hydra z failure (29)

Juki JUKI 2050 machine failure solution

Juki JUKI 2050 machine failure solution

Parts & Supplies | Pick and Place/Feeders

JUKI 2050 machine failure solution KE2050M Z-axis fault E620014 error handling method! Suddenly heard the sound of the machine. The machine stopped the fault for the E620014Z axis drive alarm. View the drive. For Z drive 1, the third light is on

ZK Electronic Technology Co., Limited

Panasonic N610071334AA / N210048234AA SMC Filter For CM402 602 212 Machine

Panasonic N610071334AA / N210048234AA SMC Filter For CM402 602 212 Machine

Parts & Supplies | Component Packaging

CM Filter N610071334AA/ N210048234AA synthetic fibre SMC Filter Element for CM402 602 212 Machine Description: 1.Part Name: Filter 2. Part Number: N610071334AA/ N210048234AA 3. Material: Fibre 4.Machine: CM402 CM602 CM212 5, Size: φ2.6x φ1.

Jinchen Electric Technology Co,.Ltd

Technical Library: hydra z failure (3)

Transient Solder Separation of BGA Solder Joint During Second Reflow Cycle

Technical Library | 2019-05-15 22:26:02.0

As the demand for higher routing density and transfer speed increases, Via-In-Pad Plated Over (VIPPO) has become more common on high-end telecommunications products. The interactions of VIPPO with other features used on a PCB such as the traditional dog-bone pad design could induce solder joints to separate during the second and thereafter reflows. The failure has been successfully reproduced, and the typical failure signature of a joint separation has been summarized.To better understand the solder separation mechanism, this study focuses on designing a test vehicle to address the following three perspectives: PCB material properties, specifically the Z-direction or out-of-plane Coefficient of Thermal Expansion (CTE); PCB thickness and back drill depth; and quantification of the driving force magnitude beyond which the separation is due to occur.

Cisco Systems, Inc.

Controlling Moisture during Inner layer Processing

Technical Library | 2024-09-02 18:48:58.0

The conversion to higher temperature "Lead Free" assembly reflow conditions has created an increased awareness that entrapped or absorbed moisture is a frequent root cause of thermally induced delamination at assembly reflow. There are two connected failure modes from entrapped moisture; incomplete resin cross-linking resulting in premature resin decomposition and also severe Z axis expansion from "explosive vaporization of the entrapped moisture at elevated temperatures at assembly reflow". Ultimately, both result in delamination failure. Other papers have shown the negative effects of entrapped moisture before lamination including delamination, red color, reduced thermal reliability and increased high speed signal loss. In this paper, various materials were tested for moisture sensitivity during lamination. Tests were performed at varying lamination conditions including a pre-vacuum step and "kiss" step. Pressure and cure temperature parameters were evaluated for minimizing or eliminating the effect of trapped moisture. Also included are the results of inner layer moisture removal baking conditions and their effect on peel strength and thermal reliability.

MacDermid, Inc.

Videos: hydra z failure (16)

Mydata MY12 SMT Pick and Place

Mydata MY12 SMT Pick and Place

Videos

2004 Mydata MY 12 SMT Pick and Place Power: 210 / 121VAC; 3 Phase Machine Dimensions: 132" x 48" x 60" Features: Electrical two-pole test Optical Centering HYDRA; HYDRA High Speed Z High Speed; Autoteach Line Scan Software Version 2.4.6b

Baja Bid

Operational Video

Operational Video

Videos

Mydata MY100-10

Baja Bid

Career Center - Jobs: hydra z failure (2)

Quality Engineer

Career Center | Santa Ana, California USA | Engineering,Quality Control

General Purpose: This position for a Quality Engineer must have electronics manufacturing and/or cable experience. Your electronics manufacturing background, PCBA, cabling experience, and expertise in auditing and maintaining AS9001 will be the keys

MX Memory Experts

Lead Manufacturing Engineer

Career Center | Clifton, New Jersey USA | Engineering,Production

L3Harris is seeking an engineer to lead manufacturing and space vehicle integration related activities on the GPSIIIF and NTS3 program. The type of space flight hardware produced at this L3Harris location includes complex circuit card assemblies (CCA

L3 Communications, Telemetry and Instrumentation

Career Center - Resumes: hydra z failure (6)

resume

Career Center | , District of Columbia | Engineering,Management,Production,Sales/Marketing

• Strong technical leadership and decision-making skills; strong verbal and written communication skills to provide clear, crisp direction for key issue resolution; and good team skills to facilitate cross-functional cross -site team effectiveness.

Manufacturing engineer & SMT process engineer

Career Center | Riyadh 11623, Philippines | Engineering,Maintenance,Production

PROFESSIONAL EXPERIENCE: Connected in the field of manufacturing/electronics industry experienced in the line, Through Hole and Surface Mount Technology, worked on various Fuji Machines Universal model, such as: CP 643E chip shooter QP 242E chip mou

Express Newsletter: hydra z failure (317)

Partner Websites: hydra z failure (285)

juki smt nozzles Archives - Page 6 of 10 - PCBASupplies

| https://pcbasupplies.com/product-tag/juki-smt-nozzles/page/6/

: high to low Custom Micronic/Mydata Midas Melf Tool for large blue arrester [2011-0906] $ 345.00 Add to cart Custom Mydata Hydra Nozzle with plastic tip for Kingbright KPTD leds [2015-2453

2005 Mydata MY12 SMT Pick & Place - Baja Bid LLC

Baja Bid | https://bajabid.com/product/mydata-my12-2005/

:   2005 Additional Photos : https://www.dropbox.com/sh/f11k8btc9vjuk9k/AACK7_JB7IZnYXRFpfCa-2WFa?dl=0 Features: S/W: 2.9.15C Electrical two-pole test Optical Centering Conveyor Hydra Z high speed Hydra high speed Autoteach Linescan for ZMyplan Condition:  Complete

Baja Bid


hydra z failure searches for Companies, Equipment, Machines, Suppliers & Information

Sm t t t t t t t t t t net
  1 2 3 4 5 6 7 8 9 10 Next
Fluid Dispensing Aerospace

We offer SMT Nozzles, feeders and spare parts globally. Find out more
SMT feeders

High Precision Fluid Dispensers
SMT feeders

High Throughput Reflow Oven
Software for SMT

Training online, at your facility, or at one of our worldwide training centers"