Industry Directory: ionic cleanliness (4)

Advanced Cleaning Solutions

Industry Directory | Manufacturer

Our services include precision PCB cleaning and ionic cleanliness testing/verification using either the Omega 600 or Zero Ion

Foresite Inc.

Industry Directory | Consultant / Service Provider / Manufacturer

Foresite is a process consulting house and analytial laboratory dedicated to solving product reliability challenges for electronics manufacturers.

New SMT Equipment: ionic cleanliness (23)

Qualification of Bare Boards

Qualification of Bare Boards

New Equipment | Test Services

Qualification of boards and assemblies is the comparison of the board or assembly to an industry standard. Specifically, we qualify printed circuit boards to IPC-6012 – Qualification and Performance Specifications for Rigid Printed Boards and

ACI Technologies, Inc.

Advanced SMT PCBA Cleaning Machine for Pristine Circuit Assembly

Advanced SMT PCBA Cleaning Machine for Pristine Circuit Assembly

New Equipment | Cleaning Equipment

Advanced SMT PCBA Cleaning Machine for Pristine Circuit Assembly ❙ Introduce of PCBA Cleaning Machine Introducing our state-of-the-art SMT PCBA Cleaning Machine, a revolutionary breakthrough in the realm of circuit board assembly. Irrespective

I.C.T ( Dongguan Intercontinental Technology Co., Ltd. )

Electronics Forum: ionic cleanliness (126)

assembly cleanliness and ionic testing

Electronics Forum | Sat Feb 14 08:21:13 EST 2009 | davef

We believe that it's perfectly resonable for you to define the cleanliness that you require. We recommend that you leave it at that and not define the process or materials that your supplier use in meeting that cleanliness level. Start with a dirty

assembly cleanliness and ionic testing

Electronics Forum | Fri Feb 13 16:13:20 EST 2009 | jax

Many shops require levels for typical component packages on FR-4 or a like substrate to be 2, 9, 15, 1 and 10 mg/in2 for fluoride, chloride, bromide, nitrate, and sulfate respectively. These levels can change for Medical or Automotive.

Used SMT Equipment: ionic cleanliness (1)

SCS Ionograph 500M SMDII

SCS Ionograph 500M SMDII

Used SMT Equipment | Cleanliness Testers

Cookson Electronics SCS - Specialty Coating Systems Ionograph 500M Model Number: SMD II Serial Number: 136848 Ionic Contamination Tester Voltage: 115V - 60HZ - 1 Phase Comes with PC and Accessories Includes Manual Good Condition Location: Bo

1st Place Machinery Inc.

Industry News: ionic cleanliness (189)

IPC & SMTA to Host Hi-Rel Cleaning & Conformal Coating Conference

Industry News | 2018-09-23 09:57:15.0

Industry-leading associations IPC and SMTA jointly announce the High-Reliability Cleaning and Conformal Coating Conference, scheduled to take place November 13-15, 2018 at Chicago Marriott, Schaumburg, Illinois. The conference is focused on the cleanliness of highly dense electronic assemblies to achieve quality and reliability within the stated in-field environment.

Association Connecting Electronics Industries (IPC)

Electrochemical Reliability Is the Focus of Session 4 at SMTA Europe's Harsh Environments

Industry News | 2018-04-15 20:01:15.0

SMTA Europe announces Session 4 Technical Program on Electrochemical Reliability at the “Electronics in Harsh Environments Conference” to be held in Amsterdam, Netherlands, on April 25th, 2018.

Surface Mount Technology Association (SMTA)

Technical Library: ionic cleanliness (8)

Cleanliness/Corrosion Mitigation

Technical Library | 2019-09-27 09:14:41.0

One of the most critical factors in preventing corrosion from occurring in electronics is maintaining the state of cleanliness. This is not an easy feat to achieve. Corrosion is defined as the deterioration of a material or its properties due to a reaction of that material with its chemical environment. [1] So, to prevent corrosion from occurring, either the material or the chemical environment must be adjusted. Adjusting the material usually means application of a protective coating or replacing a more reactive material with a less reactive material. Adjusting the chemical environment usually means removing ionic species through cleaning, and removing moisture, usually with a conformal coating or hermetic package. Ionic species and moisture are problematic because they form an electrolyte which is able to conduct ions and electricity. Any metal that comes into contact with the electrolyte can begin to corrode.

ACI Technologies, Inc.

Failure Analysis – Using Ion Chromatography And Ion Chromatography/Mass Spec (IC/MS)

Technical Library | 2021-04-29 01:43:34.0

Since the 1980s the electronics industry has utilized ion chromatography (IC) analysis to understand the relationship of ions, and some organics, to product reliability. From component and board fabrication to complete electronic assemblies and their end-use environment, IC analysis has been the de facto method for evaluating ionic cleanliness of electronic hardware.

Foresite Inc.

Videos: ionic cleanliness (5)

ACI Technologies Inc. - Commercial Services - Engineering, Manufacturing, Analytical and Electronics Manufacturing Training (IPC Certification Training and Custom Electronics Manufacturing Courses)

ACI Technologies Inc. - Commercial Services - Engineering, Manufacturing, Analytical and Electronics Manufacturing Training (IPC Certification Training and Custom Electronics Manufacturing Courses)

Videos

ACI Technologies Inc. (ACI) is a scientific research corporation dedicated to the advancement of electronics manufacturing processes and materials for The Department of Defense and industry. This video provides an overview of our commercial service

ACI Technologies, Inc.

HeatShieldGel(TM)

HeatShieldGel(TM)

Videos

To order, visit http://www.solder.net/products/heatshieldgel-tm/ BEST HeatShield Gel™ is a thermal shield water-based gel designed to be used in the PCB rework/repair or board assembly areas in order to provide thermal protection of electronic compo

BEST Inc.

Events Calendar: ionic cleanliness (7)

Risk Analysis in Electronic Assemblies

Events Calendar | Tue Sep 22 00:00:00 EDT 2020 - Tue Sep 22 00:00:00 EDT 2020 | Eden Prairie, Minnesota USA

Risk Analysis in Electronic Assemblies

Surface Mount Technology Association (SMTA)

Practical Set-Up, Qualification of Cleaning Process in PCB Assembly

Events Calendar | Mon Jun 08 00:00:00 EDT 2020 - Mon Jun 08 00:00:00 EDT 2020 | ,

Practical Set-Up, Qualification of Cleaning Process in PCB Assembly

Surface Mount Technology Association (SMTA)

Career Center - Jobs: ionic cleanliness (3)

Quality Inspector

Career Center | Milpitas, California USA | Production,Quality Control

Winslow Automation, Inc. (aka Six Sigma), an industry leader in electronic component interconnect technology & related test and failure analysis services, is seeking an experienced, detail-oriented, quality-conscious team player for our Quality Assur

Winslow Automation (aka Six Sigma)

Materials Engineer and Lab Supervisor

Career Center | Milpitas, California USA | Clerical,Production,Quality Control,Research and Development,Technical Support

Winslow Automation, Inc. (aka Six Sigma), an industry leader in electronic component interconnect technology & related test and failure analysis services, is seeking a ‘hands on’ Materials Engineer to join our Test services team. This individual wi

Winslow Automation (aka Six Sigma)

Express Newsletter: ionic cleanliness (97)

Cleanliness of Stencils and Cleaned Misprinted Circuit Boards

Cleanliness of Stencils and Cleaned Misprinted Circuit Boards Cleanliness of Stencils and Cleaned Misprinted Circuit Boards There are long-established standards and test methods for ionic cleanliness levels for bare printed circuit boards

Partner Websites: ionic cleanliness (15)

Omega Meter 600R

1st Place Machinery Inc. | http://www.firstplacemachinery.com/firstplace_alpha_metals.html

Omega Meter 600R   Alpha Metals Omega Meter   Ionic Contamination Test System to perform Cleanliness Testing  Model Number: 600R Serial Number: 06847 Microprocessor Controlled Power Requirements

1st Place Machinery Inc.

Aqueous ZERO-ION G3 Cleaner ID_53734: World Equipment Source

| https://www.wesource.com/lab-equipment/aqueous-zero-ion-g3-cleaner-id-53734/

: 11/16/2010 Ionic contamination testers were designed and implemented for the purpose of determining and monitoring the cleanliness of assemblies


ionic cleanliness searches for Companies, Equipment, Machines, Suppliers & Information

Sm t t t t t t t t t t net