Electronics Forum | Mon Jun 28 10:03:22 EDT 2004 | davef
First, welcome to your new job. Second, IPC-TM-650 2.6.14 is only loosely an �Ionic Contamination (Electromigration) Test�. * Electromigration Test, IPC TM 650 2.6.14, 2.6.14.1 * Ion Chromatography for Ionic Cleanliness, IPC TM 650 2.3.28 Third, I
Electronics Forum | Sun Jun 27 10:48:46 EDT 2004 | crios
I am a Quality Engineer which went from an Automotive QS9000 company manufacturing ceramic hybrid boards and now I am with a ISO PC mfg. company dealing with PCBA boards. I've been assigned a task in determining the contributing factor to high contam
PCB Libraries, Inc. | https://www.pcblibraries.com/forum/cleanliness-test_topic1738_post7101.html
PCBA Cleanliness test process? For Ionic Residues on PCBA, there are three methods of testing in IPC-TM-650: Dynamic Extraction Methods, Static Extraction Methods and manual method
ASYMTEK Products | Nordson Electronics Solutions | https://www.nordson.com/de-DE/divisions/dage/test-types-2020/flexural-test
Prüfung zu beenden, sowie eine Verbindung versagt hat. Test können durchgeführt werden für: ASTM D790 und D6272 IPC-TM-650 SEMI G86-0303 JEDEC 9702 Download