Industry Directory: metallic salts (2)

Utilise Gold

Industry Directory |

Utilise Gold contains an international business directory of suppliers of precious metal materials used in the electronics industry, including contacts, plating salts, pastes, solders, bonding wires and evaporation materials.

ARCONIUM

Industry Directory | Manufacturer

Manufacturer of indium-based specialty metals and chemicals

New SMT Equipment: metallic salts (28)

Kapp Copper-Bond Flux 500°F - 750°F (260°C - 390°C)

Kapp Copper-Bond Flux 500°F - 750°F (260°C - 390°C)

New Equipment | Solder Materials

Flux designed specifically to work with KappZapp7, 7.0% Silver solder to remove the oxide layer on Copper to allow a strong metallic bond between the solder and the base metal. Its active range is 500°F - 750°F (260°C - 390°C). Kapp Copper-Bond Flux

Solder Direct

Kapp Copper-Bond Flux - High Temperature Soldering Flux

Kapp Copper-Bond Flux - High Temperature Soldering Flux

New Equipment | Solder Materials

Kapp Copper-Bond Flux™ has been designed for high temperature soldering of all common metals except Aluminum. Kapp Copper-Bond Flux™ is an activated liquid flux containing a mixture of inorganic salts in water, with approximately 50% active ingredien

Kapp Alloy & Wire, Inc

Electronics Forum: metallic salts (23)

Flux residue on connector pins

Electronics Forum | Sun Aug 29 19:17:34 EDT 2004 | aqueous

Chen, It is always best to place one�s effort on determining the cause and content of the residue rather than trying to work around it. The first thing you must determine is the nature of the residue. Is it flux? In many instances, the residue is

Encapsulating water soluble flux residue?

Electronics Forum | Fri Dec 16 11:21:18 EST 2005 | patrickbruneel

Steve, Water-soluble fluxes are per definition very corrosive and need to be cleaned (read the data sheet) Encapsulation will prevent humidity reaching the water-soluble acids but will not prevent reducing the metals the flux is in contact with to m

Industry News: metallic salts (11)

Electrovert and Zestron to host a Joint Inline Cleaning Workshop in Ingolstadt

Industry News | 2018-09-05 20:22:26.0

ITW EAE will be demonstrating its Electrovert Inline cleaning equipment at a joint workshop hosted by Electrovert and Zestron. The workshop will take place October 11-12 at Zestron’s Technical Center in Ingolstadt, Germany. Participants will have a unique opportunity to learn first-hand from cleaning technology experts and observe the entire cleaning process and cleanliness evaluation. The event will offer an exchange of knowledge and networking with others who have similar cleaning challenges.

ITW EAE

The principle of vacuum soldering system is explained in this paper

Industry News | 2019-12-16 22:45:13.0

Vacuum soldering system is a kind of process welding furnace for high-end products, such as laser devices, aerospace, electric cars and other industries, compared to the traditional chain furnace, has great technical advantages.

Beijing Technology Company

Technical Library: metallic salts (3)

Influence of Salt Residues on BGA Head on Pillow (Hip)

Technical Library | 2016-05-26 15:07:36.0

The oxide layers are known as wetting inhibitors in component and PCB metallizations. The oxide acts as barrier that prevent the tin diffusion from happening. Besides, in corrosion studies, the role of salt residues -with Cl ion- on some metals is known as being promoters of oxidation or corrosion. On the other hand, most of corrosion studies with tin metallization are focused mainly on the corrosion resistance of tin alloys, but little has been done respecting to the influence of salts on tin metallization wetting. In this paper, a series of experiments was carried over to know the influence of specifically NaCl on BGA wetting given Head in Pillow (HiP) as result.

Continental Corporation

Why salt spray chamber fail to spray salt mist?

Technical Library | 2019-11-20 22:44:25.0

Salt spray test chamber is used to test teh salt corrosion resistance ability of hardware, metal and other auto parts,the chamber can quickly detect the corrosion resistance degree of products in the temperature, humidity and salt spraying environment, which can effectively improve production efficiency. So what is the reason why such a salt spray test chamber does not spray? As per our past maintenance experience,there are below reasons,customers can have a look,hope it is helpful: 1, the spray tower is blocked; 2, water pipes clogged, water flow can not go in; 3, the air compressor stops running,pls open the air compressor button; 4, main switch of the air compressor outlet is not turned on,pls turn on. 5, the solenoid valve fails, the pressure meter is broken or the pressure is too low, pls check with Climatest and repair it. 6, when the nozzle is clogged, the nozzle should be carefully removed and cleaned,because it is fragile. 7, if the spray pressure is normal, the position of the nozzle glass is also correct, but what is the reason for not spraying? In this case, it is necessary to carefully observe whether there is dirt at the contact surface of the nozzle. If so, clean up the dirt and the spray can be carried out normally. That‘s all we‘re going to talk about today. If you have any questions, follow us on facebook, Please feel free to ask us questions.

Symor Instrument Equipment Co.,Ltd

Express Newsletter: metallic salts (161)

SMTnet Express - May 26, 2016

SMTnet Express, May 26, 2016, Subscribers: 24,776, Companies: 14,803, Users: 40,361 Influence of Salt Residues on BGA Head on Pillow (Hip) J. Servin, P. Gomez, M. Dominguez, A. Aragon; Continental Corporation The oxide layers are known as wetting

Partner Websites: metallic salts (3)


metallic salts searches for Companies, Equipment, Machines, Suppliers & Information

Sm t t t t t t t t t t net
  1 2 3 4 5 6 7 8 9 10 Next