Industry Directory: omegameter 600smd ionic test system used (1)

Specialty Coating Systems

Industry Directory | Manufacturer

For over 40 years, Specialty Coating Systems has provided high quality Parylene conformal coating services and expertise to the medical device, electronics, automotive and military/aerospace industries.

New SMT Equipment: omegameter 600smd ionic test system used (7)

StencilQuik™ BGA Rework Stencils

StencilQuik™ BGA Rework Stencils

New Equipment | Solder Paste Stencils

Eliminate hours of solder mask damage repair time for bga sites while improving rework yield. Are you frustrated by the time it takes to repair mask damage underneath the BGA during the rework process?  Are you squeezed for space on the PCB in an

BEST Inc.

Ionograph® SMD V - Ionic Contamination Test System

Ionograph® SMD V - Ionic Contamination Test System

New Equipment | Test Equipment

Fast and accurate ionic contamination cleanliness testing. Dynamic testing of ionic contamination is a widely approved and followed standard. So, too, is the equipment that makes it possible - SCS Ionograph®. Available in different models, the SCS

Specialty Coating Systems

Electronics Forum: omegameter 600smd ionic test system used (62)

ionic residues on the surface of printed circuit assemblies

Electronics Forum | Wed Sep 02 16:41:44 EDT 2009 | pcbcleaning

Advanced Cleaning Solutions is a Johnstown, PA based electronic manufacturing service provider (EMS) with more than 3,500 square feet of ESD safe facilities. Our services include precision PCB cleaning and ionic cleanliness testing/verification usin

Contamination test

Electronics Forum | Mon Jul 30 21:03:44 EDT 2001 | davef

You should specify the level of res based on the effect of the res on the end-use of the product. J-STD-001 defines cleanliness requirements for ALL flux types, including water soluble and no-clean that you mention. 1 There is no equivalency betwee

Used SMT Equipment: omegameter 600smd ionic test system used (2)

SCS 600 SMD Omegameter (2013)

SCS 600 SMD Omegameter (2013)

Used SMT Equipment | General Purpose Test & Measurement

SCS 600 SMD Omegameter (2013) Brand: Specialty Coating Systems Model number: OM 600 Year: 2013 S/N: 145837 Volts: 240, 10 amps, single phase, 50/60 Hz Int. Capacity: 300A Dimensions: 38" x 29" x 54" Weight: 500 lb Solution capacity: 10 gal. System

Tekmart International Inc.

SCS 600 SMD Omegameter

SCS 600 SMD Omegameter

Used SMT Equipment | Coating and Encapsulation

SCS 600 SMD Omegameter (2013) Brand: Specialty Coating Systems Model number: OM 600 Year: 2013 S/N: 145837 Volts: 240, 10 amps, single phase, 50/60 Hz Int. Capacity: 300A Dimensions: 38" x 29" x 54" Weight: 500 lb Solution capacity: 10 gal. System

Tekmart International Inc.

Industry News: omegameter 600smd ionic test system used (117)

SMT Dictionary – Surface Mount Technology Acronym and Abbreviation

Industry News | 2018-12-08 03:29:29.0

SMT Dictionary – Surface Mount Technology Acronym and Abbreviation

Flason Electronic Co.,limited

Specialty Coating Systems Debuts New-Generation Omegameter SMD 650 Ionic Testing System

Industry News | 2017-10-11 17:23:58.0

Specialty Coating Systems (SCS) announced today the launch of the Omegameter SMD 650, the next-generation, software-controlled Omegameter ionic contamination test system.

Specialty Coating Systems

Technical Library: omegameter 600smd ionic test system used (1)

Comparison of ROSE, C3/IC, and SIR as an effective cleanliness verification test for post soldered PCBA

Technical Library | 2023-04-17 21:17:59.0

The purpose of this paper is to evaluate and compare the effectiveness and sensitivity of different cleanliness verification tests for post soldered printed circuit board assemblies (PCBAs) to provide an understanding of current industry practice for ionic contamination detection limits. Design/methodology/approach – PCBAs were subjected to different flux residue cleaning dwell times and cleanliness levels were verified with resistivity of solvent extract, critical cleanliness control (C3) test, and ion chromatography analyses to provide results capable of differentiating different sensitivity levels for each test. Findings – This study provides an understanding of current industry practice for ionic contamination detection using verification tests with different detection sensitivity levels. Some of the available cleanliness monitoring systems, particularly at critical areas of circuitry that are prone to product failure and residue entrapment, may have been overlooked. Research limitations/implications – Only Sn/Pb, clean type flux residue was evaluated. Thus, the current study was not an all encompassing project that is representative of other chemistry-based flux residues. Practical implications – The paper provides a reference that can be used to determine the most suitable and effective verification test for the detection of ionic contamination on PCBAs. Originality/value – Flux residue-related problems have long existed in the industry. The findings presented in this paper give a basic understanding to PCBA manufacturers when they are trying to choose the most suitable and effective verification test for the detection of ionic contamination on their products. Hence, the negative impact of flux residue on the respective product's long-term reliability and performance can be minimized and monitored effectively.

Jabil Circuit, Inc.

Videos: omegameter 600smd ionic test system used (3)

SMD Reflow Oven

SMD Reflow Oven

Videos

Middle Size Lead Free SMT Reflow Oven for LED A600 Model: A600 MID-sized Lead-free Reflow Oven(6-zone) Brief: Lead-free reflow soldering Heating System > Eight groups of top and bottom forced hot air convection heating zones. > Patented heati

Dongguan Intercontinental Technology Co., Ltd.

StencilQuik demonstration video. This breakthrough method allows you to simplify placement/replacement saving 50% or more of time required to rework BGAs or CSPs.This is a well developed BGA rework method.

StencilQuik demonstration video. This breakthrough method allows you to simplify placement/replacement saving 50% or more of time required to rework BGAs or CSPs.This is a well developed BGA rework method.

Videos

StencilQuik demonstration video. This breakthrough method allows you to simplify placement/replacement saving 50% or more of time required to rework BGAs or CSPs.This is a well developed BGA rework method. More on the StencilQuik(TM) process here:

BEST Inc.

Training Courses: omegameter 600smd ionic test system used (1)

Career Center - Jobs: omegameter 600smd ionic test system used (1)

Material Lab Technician

Career Center | Milpitas, California USA | Engineering,Production,Quality Control,Research and Development,Technical Support

Winslow Automation, Inc. (aka Six Sigma), an industry leader in electronic component interconnect technology & related test and failure analysis services, is seeking individuals specializing in materials lab testing to join our team. We have openin

Winslow Automation (aka Six Sigma)

Career Center - Resumes: omegameter 600smd ionic test system used (1)

Process Engineer

Career Center | san diego,, California USA | Engineering,Production,Quality Control,Technical Support

SMT Process Engineer, ISO-9001, IPC-600/610/620/7711/7721, J-STD-001, Thermal profiling, Lean manufacturing.

Express Newsletter: omegameter 600smd ionic test system used (1133)

SMTnet Express - July 13, 2017

SMTnet Express, July 13, 2017, Subscribers: 30,584, Companies: 10,624, Users: 23,496 Divergence in Test Results Using IPC Standard SIR and Ionic Contamination Measurements K. Tellefsen, M. Holtzer, T. Cucu, M. Liberatore, M. Schmidt - Alpha

Partner Websites: omegameter 600smd ionic test system used (37)

Underfilling Equipment & Materials | Nordson

ASYMTEK Products | Nordson Electronics Solutions | https://www.nordson.com/en/applications/underfilling?con=t&page=21

& Product Lines ADVANCED TECHNOLOGY SOLUTIONS ● Nordson ELECTRONICS SOLUTIONS     ◦ ASYMTEK Products     ◦ MARCH Products     ◦ SELECT Products ● Nordson EFD ● Nordson MEDICAL ● Nordson TEST & INSPECTION     ◦ ACOUSTIC Products     ◦ OPTICAL Products     ◦ TEST Products     ◦ Manual X-ray Products

ASYMTEK Products | Nordson Electronics Solutions

Webinars and Webtorials

Surface Mount Technology Association (SMTA) | https://www.smta.org/education/presentations/presentations.cfm

.  Three surface finishes including OSP, ImAg, and ENIG are considered. The test vehicle consists of 15mm and 6mm Ball Grid Array (BGA) components. The assembled test boards were isothermally aged at 125oC for 12 months, which are then thermally cycled between -40oC to

Surface Mount Technology Association (SMTA)


omegameter 600smd ionic test system used searches for Companies, Equipment, Machines, Suppliers & Information

Sm t t t t t t t t t t net
  1 2 3 4 5 6 7 8 9 10 Next
PCB Handling Machine with CE

Training online, at your facility, or at one of our worldwide training centers"
Voidless Reflow Soldering

Nozzles, Feeders, Spare Parts - Siemens, Fuji, Juki, Yamaha, etc...
High Throughput Reflow Oven

Component Placement 101 Training Course
Win Source Online Electronic parts

Software for SMT placement & AOI - Free Download.