、UV curing machine UV light source type: Mercury light source Lamp replacement cycle 800-1500H Irradiation effective range 450mm Equipment ventilation 2 φ150 air outlets for optimal furnace temperature control Exhaust volume requirements 1200 m³/h P
New Equipment | Coating Equipment
The Viscosity Control System maintains consistent temperature of conformal coating fluids. The system includes a heated recirculating fluid circuit to eliminate viscosity changes in temperature-responsive materials. Close-range temperature monitoring
Electronics Forum | Mon Apr 12 09:13:45 EDT 2010 | toddl
Check your "over temperature module" for both top and bottom zones when the alarm is active, there is a bank of LED's on the bottom of this module. Monitor it to find out if the same zone keeps activating the alarm, if so check your TC for that zone.
Electronics Forum | Fri Oct 03 04:24:54 EDT 2014 | dcarroway
Does any one have a wiring diagram for an electrovert Omni 10. We are having trouble finding why zone 7 runs over temperature.
Used SMT Equipment | Soldering - Reflow
Heating zones: 5 Cooling zones: 2 Total heating length: 66 in. Total cooling length: 26 in. Total process length: 127 in. Total on /off load length: 11 in. Overall system length: 138.5 in. Overall system width: 52 in. Overall system height: 5
Used SMT Equipment | Soldering - Reflow
Perfect condition. 10 heating zones three cooling zones Power hood lifts RS-232 interface with PID microprocessorbased controller Combination belt and edge/rail conveyor Safety interlocks on electrical panels Over temp
Industry News | 2019-04-16 11:07:30.0
Innovative Solutions, test your IC Device with confidence without ever worrying about temperature requirements
Industry News | 2012-10-11 14:37:16.0
For years the Weller name has been the authority in soldering and electrical repair. Their products are built to last and are always on the cutting edge of technology. With Kimco you get a complete Weller soldering station with the WX2 station with WXMP-MS soldering iron and WDH51 tool stand, WXMT-MS de-soldering tweezer and WDH60 tool stand.
Parts & Supplies | Repair/Rework
PG-P6800 Main Features: 1、There are 3 independent heaters. The 1st and 2nd hot-air heaters can control multiple groups and segments temperature parameters. The 2nd heater can move up and down. The 3rd large area IR heater can preheat the PCB boar
Parts & Supplies | Repair/Rework
PG-P6860 Main Features: 1、 The top heater can move freely along the X, Y axis in the IR preheating area. It is good for many BGA chips distribution at different positions in the PCB board which need repair. X-shaped infrared laser can do rapid lo
Technical Library | 2019-05-21 00:21:26.0
Continue to talk about the dust removal from temperature humidity test chamber. Cleaning and maintenance: 1) Pls remove internal impurities inisde chamber before operation. 2) The power distribution room should be cleaned at least once a year, and the dust can be removed by vacuum cleaner. 3) The exterior chamber must also be cleaned more than once a year, which can be wiped with soapy water. Inspection and maintenance of humidifier: The water storage in humidifier should be replaced once a month to ensure clean water quality, humidifying water tray should be cleaned once a month to ensure smooth flow of water. The inspection of over-temperature protector:during the test: If the temperature is over 20 ℃ ~ 30 ℃ than the maximum value setted,the power supply of the heater will stop, the "OVERHEAT" overt-emperature warning light will automatically turn on but the fan is still in operation, if the equipment runs without operator around,the operator should check the over-temperature protector in advance to ensure wether it has been setted properly before start [wet ball over-temperature protector set to 120 ℃].
Technical Library | 2016-05-13 11:44:16.0
The process of manufacturing and qualifying IC's consists of many steps while Temperature forcing systems play a crucial role in the final testing process. These environmental tests assure quality and reliability by stressing the device on one hand as well as helping to characterize and validate it on the other hand (making sure manufacturing outcome meets the design requirements). At later stages the temperature testing can support failure analysis effort and root cause analysis. AS common practice we are dealing with few different kinds of temperature forcing systems: Chambers, Thermal Stream systems and Direct Thermal Head systems. In this article I would like to focus on the practical aspects of utilizing Thermal Stream systems and Direct Thermal Head systems.
ETA & MARS High-end Wave Soldering Machine If you could not find any similar items you want, you may send some photos to us. because our catalog and website haven't included allof our products. wave soldering, wave soldering machine, DIP so
ETA W2 Wave Soldering Equipment If you could not find any similar items you want, you may send some photos to us. because our catalog and website haven't included allof our products. wave soldering, wave soldering machine, DIP soldering, select
SMTnet Express, October 3, 2019, Subscribers: 32,260, Companies: 10,890, Users: 25,178 Effects of Temperature Uniformity on Package Warpage Credits: Akrometrix Knowing how package warpage changes over temperature is a critical variable in order
| http://etasmt.com/cc?ID=te_news_bulletin,12961&url=_print
transport dynamic display. 4.New cooling zone, quick and easy adjustment. 5. I.C.T using third-party over-temperature protection, multiple layers protection to ensure safe operation. 6.Heating module
ASYMTEK Products | Nordson Electronics Solutions | https://www.nordson.com/en/divisions/dage/test-types-2020/creep-test
. The dimensional changes that occur with time when materials are statically loaded, is referred to as creep. Creep measurements are important for solders, polymers and adhesives where large strains can develop over time and strain rates are very temperature sensitive