Industry Directory | Manufacturer
Through innovative technology and custom-engineered designs, CET provides unique solutions for today's market-driven requirements. CET stands out in the industry with an unmatched ability to meet each customer's specific design needs.
Industry Directory | Manufacturer
Professional manufacturer of PTC & NTC thermistor, temperature sensor pressure Sensors. Thermistors for overload over-current protect, inrush current limit, temperature sense measurement compensation control, protect.
Cooper Electronic Technologies brings to the marketplace the power of Bussmann Fuses - 80 years of commitment to the fuse philosophy of circuit protection. Bussmann fuses are truly fail-safe protective devices since they are non-dependent upon mechan
New Equipment | Component Programming
In System Programmer for PIC, AVR and dsPIC microcontrollers plus serial EEPROMs, dataflash and other ISP devices. Includes DLL and Go button for easy production use. AVR, PIC, dsPIC microcontrollers supported Very fast programmer operation ICS
Electronics Forum | Wed Nov 23 07:45:39 EST 2016 | bukas
hello, I have a GSM2 machine with faulty motor driver (i guess), usually when this error occurs i would rest it via button on a panel several times, but this time it doesnt work. what should i check/ measure to locate this problem? there is 7 blink
Electronics Forum | Sun May 02 14:37:06 EDT 2010 | dekhead
Something is surging on the 5V line tripping overcurrent on PSU2... If you've got autoflex on the machine the Y15 is th most likely culprit... I've also seen it with the Y2. www.dekhead.com
Used SMT Equipment | General Purpose Test & Measurement
Model Type: OVS-4 Thermal Supply Voltage: 480 Phase: 3 HZ: 60 Full Load Amps (FLA): 90A Maximum Circuit Protection: 200A Heater Fla: 77A 64kw, Motor Fla: 2.7A 2HP Disconnect Switch Max Interrupt/Capacity: 14.000A Overcurrent Protection Provide
Used SMT Equipment | In-Circuit Testers
Agilent 6653A The 6653A Power Supply is rated at 35 V @ 15 A and features: HP-IB Linear Output Regulation Complete Front Panel Control Calibration and Display Fan-speed control to minimize acoustic noise Low ripple and noise Over-voltage and over
Industry News | 2003-03-06 08:10:20.0
Astec Power has expanded its popular APC-Centauri surface-mount product line to include a series of 40W point-of-load DC/DC convertors.
Industry News | 2017-09-25 22:56:44.0
In most cases,the tantalum electrolytic can replace aluminum electrolytic while not considering capacity and voltage.But in the way of tolerance transient overpressure and transient overcurrent, aluminum electrolytic is better than tantalum electrolysis.In flexible usage of certain situations, it can make a slight reverse voltage in both ends of the capacitor, same as tantalum electrolytic.
Technical Library | 2019-12-12 02:43:44.0
Today we discuss the reason that causes temperature humidity chamber to alarm,In most cases, the equipment alarm is caused by the improper operation in the process of use, which mainly includes following reasons:that are refrigeration system, temperature system and circulating system. First, Refrigeration system 1, refrigeration compressor overpressure alarm. If the refrigerant pressure exceeds the set value, it will stop and alarm at the same time. At this time, the fault must be eliminated and then manually reset. 2, short phase power supply, phase sequence alarm. When the external power supply of the equipment is out of phase or the phase sequence is changed, it will stop and alarm at the same time. 3. The circulating cooling water is short of water to alarm. When the water pressure of the cooling circulating water system is insufficient, it will stop and alarm at the same time, and it must wait for the fault to be eliminated and reset at the same time before it could run normally. 4, refrigeration compressor overheating alarm. When the coil of the compressor is overheated and the power supply of the line is not normal, it will stop and alarm at the same time. Second, Temperature system 1, the overtemperature alarm in the chamber. The sensors in the channel and the sample area are equipped with overtemperature protection devices, and there are also overtemperature protecter on the control panel. When the temperature in the working chamber exceeds the setting value on the controller, it will stop and alarm. 2. sample overtemperature protection. When the temperature in the sample area exceeds the protection temperature set by the controller, it will stop and alarm at the same time. The overtemperature protection of the sample is divided into upper limit protection and lower limit protection, which can be set according to the demand, Third,Circulating system 1. The alarm is caused by the overheating of the circulating fan. When the coil of the fan is over-heated, the alarm will be stopped at the same time. 2. The fan over-current alarm. When the current of the fan exceeds the allowable value, the alarm is stopped at the same time, and the normal operation can only be carried out after the fault maintenance of the overcurrent is completed. This is what we talk about today,if you have more questions,let us know.
Agilent 6038A Agilent/HP 6038A System Autoranging DC Power Supply, 60V, 10A The 6038A Autoranging System Power Supply HP-IB programmable CV/CC DC power supply has many productivity-oriented features which makes it easy to program and integrate