New Equipment | Test Equipment
For over 40 years the Benchmark for Ionic Contamination Testing Commonly referred to "Cleanliness Testing" as this test method has, for over 40 years, been acknowledged as an important Quality Assurance and Process Control tool in the manufacture of
Electronics Forum | Fri Jan 03 19:17:12 EST 2003 | Mike Konrad
Hi Richard My experience with R.O.S.E. testers has been positive with regard to detecting ionic contamination (even exceptionally low levels). As previously mentioned, a good R.O.S.E tester will be able to detect minuet levels of ionic contaminatio
Electronics Forum | Sat Sep 29 22:56:13 EDT 2007 | asoelu
the vary results might be from following issues.. the co2 during the test the during time for this testing... the manual testing method is conductivity measurement however the bulk contamination tester like omega is resistance measurement (i remem
Industry News | 2021-05-25 12:56:56.0
The SMTA Officer team is excited to provide our members with a free technical webinar on "The Relationship Between Cleanliness and Reliability/Durability" by Debbie Carboni, Global Product Manager at KYZEN Corporation. The presentation will take place on June 10th at 11:00am EST and include:
Industry News | 2017-10-18 20:01:20.0
IPC, in conjunction with IFTEC, conducted the IPC Hand Soldering Competition at IFTEC in Paris because the MIDEST exhibition, originally scheduled for October 2017 was moved to 2018. The competition was fierce as 33 competitors went soldering iron to soldering iron to take the hand soldering competition crown. Taking first place with a cash prize of €300 and a JBC Soldering Station was Catherine Cardinal-Simon from Thales Microelectronic in France, who earned 443 points out of a possible 446. Cardinal–Simon will now compete at the IPC World Championship Hand Soldering Competition located this year at productronica 2017 on 17 November.
Commonly referred to "Cleanliness Testing" as this test method has, for over 40 years, been acknowledged as an important Quality Assurance and Process Control tool in the manufacture of electronic circuit boards, components and assemblies. The Conta
Validity of the IPC R.O.S.E. Method 2.3.25 Researched Validity of the IPC R.O.S.E. Method 2.3.25 Researched This paper researches the effectiveness of the R.O.S.E. cleanliness testing process for dissolving and measuring ionic contaminants from