Electronics Forum | Wed Jul 16 14:21:15 EDT 2014 | toddp2012
Hi all, we have a Speedline Technologies ELEOCTROVERT/Aquastorm 200. In January we stared supplying it with pre-filterd to the DI cabinet next to machine so our large media would last longer. All was fine for about 4 months and then we started gett
Electronics Forum | Fri Dec 08 10:24:11 EST 2006 | pjc
The Speedline Technologies- Electrovert AquaStorm 200 is one machine that can do the trick. You'll need the Chemical Isolation option for the RMA flux and you'll need a cleaning chemistry like what Zestron and Kyzen have. Yes, hi-density boards with
Used SMT Equipment | Board Cleaners
Details: • 20" Belt Conveyor • 10 HP Hurricane Wash & Rinse Sections • 3 Turbine Dryers (Sonic Air) (2)15HP & (
Used SMT Equipment | Board Cleaners
1998 Electrovert Aquastorm 200 In-Line Wash Serial: 11873808 Features: Chemical Isolation 15 HP Upgrade Pre-Wash with V-Jet Nozzles Hurricane Wash Hurricane Rinse with V-Jet Nozzles Resist Monitor Item Location: Dracut, MA USA
Lewis & Clark | http://www.lewis-clark.com/product/2006-speedline-aquastorm-200-inline-wash-system/
: Speedline Model: Aquastorm 200 Vintage: 2008 Details: 24” Conveyor Width Chemical Isolation Package Interior Lighting 2 Additional E-Stops Auto Standby Photocell 30
| https://www.wesource.com/miscellaneous/resys-ultra-loop-pcb-water-recycling-system-w/sump-pump-id-140319/
. Chemistry cleaning applications are ideally suited for the Ultra-loop. State-of-the-art in-line cleaning systems divert water from the recirculating rinse to supply the chemical isolation (CI) rinse section (1 to 2 GPM