Industry Directory | Manufacturer
Expert in Humidity Control Cabinet (compliant to JSTD-033C), Baking Oven, Nitrogen Cabinet, Alarm Hygrometer, Wireless Monitor
New Equipment | Coating Equipment
The Viscosity Control System maintains consistent temperature of conformal coating fluids. The system includes a heated recirculating fluid circuit to eliminate viscosity changes in temperature-responsive materials. Close-range temperature monitoring
A500, A600, A800 - 5, 6 or 8 top/bottom cooling zones. Heating System: Up to eight groups of top and bottom forced hot air convection heating zones. Patented heating plates in each zone uniformly transfer heat to the PCBs using forced hot air co
Electronics Forum | Wed Sep 03 07:39:19 EDT 2008 | pjc
You may not be getting enough exhaust pull, so the cooling modules over temp. Try swapping blower motors to isolate that before buying one. STANDARD AIR OPERATION: - Load-end: 150 cfm (255 m3/hr) at the 4� (102 mm) stack (minimum requirement) - Unlo
Electronics Forum | Tue Sep 02 13:35:29 EDT 2008 | evtimov
Hi, I don;t thing there is an overtemperrature sensor. Just the thermocpouple returns a higher temp(voltage) to the controller and your software goes to alarm, cooldown or what ever it does. Emil
Used SMT Equipment | Soldering - Wave
Operating System: Windows based Details: • Dual pot-Lead and Lead Free • Includes full pot of Lead Free –SN100C solder and Lead SN63/PB37 solder • Carbon Steel Solder pots with high temperature protective coating • A
Used SMT Equipment | Soldering - Reflow
T3A Conveyor Hot-air Reflow Oven Conveyor Hot-air Reflow Oven has four (4) heating zones and (300mm) wide and (1900mm) long conveyor for low to medium volume production runs. T3A utilizes PID intelligent micro-computer automatic temperature co
Industry News | 2019-08-21 02:23:08.0
The ultra-small temperature tracker BTT01 for cold chain have many features. It can be use in many filed,such cold chian ,supply chain management.
Industry News | 2020-08-22 04:31:28.0
Scienscope International introduces the all new Infra-Scope: a high-definition surveillance system using facial recognition and high-temperature alarm.
Parts & Supplies | Pick and Place/Feeders
JUKI 750 760 OCC card Light card E86127210A0 Other parts: E86097600A0 ATC PWB ASM E86107210A0 IMG-P PWB ASM. *5 E86107230A0 ADD ON CIRCUIT BOARD ASM. E86107290A0 BACK BOARD CIRCUIT BOARD ASM. E86117060A0B REEL HOOK 56 ASM. E86117150A0 AC SERVO
Parts & Supplies | SMT Equipment
JUKI KE750/760 I/O CONTORL PWB SET E86047210A0 E8604717BA0 CTL BOARD BA ASM E86047210A0 I/O CONTROL PWB ASM. E86047210B0 I/O CONTROL PWB SET E86047250A0 OPERATION SW BOARD ASM. E8604725AA0 OPERATION BOARD A ASM. E8604725BA0 OPERATION BOARD B A
Technical Library | 2019-12-12 02:43:44.0
Today we discuss the reason that causes temperature humidity chamber to alarm,In most cases, the equipment alarm is caused by the improper operation in the process of use, which mainly includes following reasons:that are refrigeration system, temperature system and circulating system. First, Refrigeration system 1, refrigeration compressor overpressure alarm. If the refrigerant pressure exceeds the set value, it will stop and alarm at the same time. At this time, the fault must be eliminated and then manually reset. 2, short phase power supply, phase sequence alarm. When the external power supply of the equipment is out of phase or the phase sequence is changed, it will stop and alarm at the same time. 3. The circulating cooling water is short of water to alarm. When the water pressure of the cooling circulating water system is insufficient, it will stop and alarm at the same time, and it must wait for the fault to be eliminated and reset at the same time before it could run normally. 4, refrigeration compressor overheating alarm. When the coil of the compressor is overheated and the power supply of the line is not normal, it will stop and alarm at the same time. Second, Temperature system 1, the overtemperature alarm in the chamber. The sensors in the channel and the sample area are equipped with overtemperature protection devices, and there are also overtemperature protecter on the control panel. When the temperature in the working chamber exceeds the setting value on the controller, it will stop and alarm. 2. sample overtemperature protection. When the temperature in the sample area exceeds the protection temperature set by the controller, it will stop and alarm at the same time. The overtemperature protection of the sample is divided into upper limit protection and lower limit protection, which can be set according to the demand, Third,Circulating system 1. The alarm is caused by the overheating of the circulating fan. When the coil of the fan is over-heated, the alarm will be stopped at the same time. 2. The fan over-current alarm. When the current of the fan exceeds the allowable value, the alarm is stopped at the same time, and the normal operation can only be carried out after the fault maintenance of the overcurrent is completed. This is what we talk about today,if you have more questions,let us know.
Technical Library | 2019-11-13 02:09:44.0
Dry oven is a must instrument almost for every laboratory in different industries,with nearly 20 years efforts and innovation,Climatest now masters core technique of dry oven manufacturing,no matter on temperature uniformity or temperature stability.Behind the quality is 15 years of consistent persistence,strong belief in excellence; from design to R & D to production, from promotion to sales to installation; every step should reach excellence,What you see, you use our products, you choose, you feel that we do our best,this is our faith. Dry Ovens are used to dry or temper electronic components,material tests,torrefaction, wax-melting ,high temperature aging ,preheating and sterilization in industrial and mining enterprises, laboratories and scientific research institutes. .Exterior chamber is made by reinforced steel with painting; working chamber made by anti-corrosion stainless steel SUS#304 .Intelligent PID control, LED controller with over-temperature alarm,timing range within 0~9999min .Hot air circulation system composed of Germany imported low-noisy air blower and optimal air duct which ensure uniform temperature distribution .Double layers of glass door, large transparent window to observe specimen .Forced air convection Climatest manufactures desktop and floor-standing models with RT+10°C-200°C,250°C,300°C,350°C,400°C temperature range,and customized as per special requirement,if you wanna know more details about our dry oven,please visit our product page:https://climatechambers.com/industrial-dry-oven/200-degree-c-hot-air-oven.html
BESTEMP reflow checker 6 channel temperature profiler Reflow soldering temperature tester Characteristic: 1..High efficiency, data can be stored up to 16 times continuously, and can be downloard to computer for group data viewing. 2. Modular analys
A500, A600, A800 - 5, 6 or 8 top/bottom cooling zones. Heating System: Up to eight groups of top and bottom forced hot air convection heating zones. Patented heating plates in each zone uniformly transfer heat to the PCBs using forced hot air co
Events Calendar | Wed Jun 22 00:00:00 EDT 2022 - Wed Jun 22 00:00:00 EDT 2022 | ,
Empire Chapter Webinar: LIVE Action Reflow Focused Process
Career Center | Farrukh Hussain, Pakistan | Engineering,Maintenance
PLC, SCADA, designing circuit or PCB layout, troubleshooting and maintenance, electrical and instrumentation, electronics design, software skill with programming.
Career Center | Karachi, Pakistan | Engineering,Maintenance
PLC, SCADA, designing circuit or PCB layout, troubleshooting and maintenance, electrical and instrumentation, electronics design, software skill with programming.
SMTnet Express, August 26, 2021, Subscribers: 26,759, Companies: 11,431, Users: 26,816 Low Melting Temperature Sn-Bi Solder: Effect of Alloying and Nanoparticle Addition on the Microstructural, Thermal, Interfacial Bonding
GPD Global | https://www.gpd-global.com/pdf/doc/Temperature-Monitoring-Camera-Sensor-Guide-22200623.pdf
: • When a particular area exceeds a defined temperature, the camera triggers an alarm/ sends a signal to the dispense system. • The camera I/O transitions “high
ASYMTEK Products | Nordson Electronics Solutions | https://www.nordson.com/en/divisions/asymtek/products/conformal-coating-systems/viscosity-control-system
. Programmers define the process temperature and the corresponding process limits in EasyCoat ® software. If the fluid temperature moves outside the defined process limits during production, the system triggers an alarm condition and operators can intervene to prevent potential errors