conception and construction of prefabricated modular structure and air treatment systems, install hermetic rooms and buildings to control pressurisation, dust, noise, vibrations, micro-organisms, temperature, humidity, water and corrosive agents
Industry Directory | Manufacturer
ASLi main products: Temperature (humidity) chamber, Thermal Shock Test Chamber, Sand and Dust Tester , Rain Spray Tester, UV Chamber, Ozone Chamber, Xenon Climate Chamber , Salt Spray Corrosion Chamber, High Temperature (Vacuum )
New Equipment | Solder Paste Stencils
EbyDEK printer specification: ①Automatic Fiducial Setup ②Fast Print Speed ③Networking ④Small Fiducial ⑤Speed Up ⑥Tooling Deviation Monitoring ⑦Vision Plus ⑧Windows 7 Operating System Specify ①Blue USC Alternative Park ②DUI Hardware And Time To Go
A resistor is a two-terminal electronic component made of resistive material with a certain structural form that can limit the flow of current in a circuit. The resistance value of a resistance element is generally dependent on temperature, material,
Used SMT Equipment | Screen Printers
EbyDEK printer specification: ①Automatic Fiducial Setup ②Fast Print Speed ③Networking ④Small Fiducial ⑤Speed Up ⑥Tooling Deviation Monitoring ⑦Vision Plus ⑧Windows 7 Operating System Specify ①Blue USC Alternative Park ②DUI Hardware
Used SMT Equipment | Screen Printers
2.0 Cmk @ ± 12.5 μm (± 6 sigma) System alignment capability > 2.0 Cmk @ ± 25 μm (± 6 sigma) Optimum core cycle time 8 seconds Substrate size 50 mm (X) x 40.5 mm (Y) to 620 mm (X) x 508.5 mm (Y) Operating System Windows 7 Embe
Industry News | 2003-06-23 08:49:39.0
Three Organizations from the US, Europe and Japan to
Industry News | 2016-10-10 10:59:34.0
Sypris Electronics will be liquidating some of their assets utilizing the online auction services of Baja Bid. The bidding for this event will open promptly at 7:00am EDT on october 24, 2015 and the closing will begin at 11:00am EDT on November 11, 2016.
Technical Library | 2019-11-17 22:46:45.0
Overview of walk-in temperature and humidity chamber: It also belongs to environmental test equipment, it tests whether the product can resist high temperature, low temperature, humidity, or the physical and chemical changes produced under extreme conditions, the walk-in temperature and humidity chamber volume is large, the product is placed, or a large object can be placed, such as automobile, new energy, television and liquid crystal screen, etc. How to do the routine maintenance of the walk-in temperature and humidity chamber: 1. The wet gauze basically, if there is no special case, s/b usually changed once in 3 months 2. The water channel shall be regularly cleaned, including water cup, water tank, etc., so as to prevent the water from being blocked,affect the humidity test. 3. It is forbidden to test the flammable and explosive products inside working room. 4. Clean the chamber on a regular basis 2. How to operate walk-in temperature and humidity chamber: The operation method is same as standard temperature humidity test chamber,the controller is 7-inch LCD programmable color screen, you only need to setthe temperature point---test time--how many cycles need to be tested, This can be done automatically, and the machine will stop automatically when it is complete. If there is any problem during the operation, the corresponding problem point will be displayed on the machine control screen. Walk-in temperature and humidity chamber is a must equipment for reliability test of Automobile,Aerospace,Electronic parts,etc,the operation and maintenance are easy,it is teh tear down mahcine,Climatest engineers will be dispatched to do on-site support,for instance,we will finish commissioning,train customers how to operate,maintain,welcome to follow our company facebook page:https://www.facebook.com/Climatechambers
Technical Library | 2019-05-16 02:25:15.0
limatest Symor wants to tell you that humidity is not only the most important thing in the chamber, but also the temperature In order to facilitate customers to add water, our temperature and humidity test chamber is to place the water tank at back of the equipment.Just open the baffle to see the water tank and the water level meter next to the tank,then add enough water to the tank. However, in addition to manual water addition, our temperature and humidity test chamber has equipment that can automatically add water. Only by connecting the water pipe at the water filling port can it be automatically replenished when there is a shortage of water, which is suitable for high humidity test for a long time.
The ASYMTEK Qadence™ closed-loop flow control system maintains a stable flow rate by volume for high quality conformal coating results – automatically compensating for viscosity changes related to temperature, humidity and batch-to-batch variation. W
Introduction to Intelligent SMD Tower In the ever-evolving landscape of Surface Mount Technology (SMT), the I.C.T-ISS2000 stands out as a game-changer in Intelligent SMD Tower. Crafted in Europe, this cutting-edge system adheres to the highest safet
Events Calendar | Mon Aug 17 18:30:00 UTC 2020 - Mon Aug 17 18:30:00 UTC 2020 | ,
How to Minimize Humidity Interaction with PCBAs for Robustness
SMTnet Express, September 15, 2022, Subscribers: 25,064, Companies: 11,611, Users: 27,457 █ Electronics Manufacturing Technical Articles Humitector™ Type 2 Non-Reversible Humidity Indicator Cards from Clariant help assure the integrity
SMTnet Express, August 26, 2021, Subscribers: 26,759, Companies: 11,431, Users: 26,816 Low Melting Temperature Sn-Bi Solder: Effect of Alloying and Nanoparticle Addition on the Microstructural, Thermal, Interfacial Bonding
ASYMTEK Products | Nordson Electronics Solutions | https://www.nordson.com/en/divisions/asymtek/your-process/fluid-types/rtv-silicone
Room Temperature Vulcanizing (RTV) Silicone ASYMTEK Products Corporate | Global Directory | Languages Division Only All of Nordson Fluid Dispensing Systems Jets
Surface Mount Technology Association (SMTA) | https://www.smta.org/knowledge/proceedings_abstract.cfm?PROC_ID=5027
Effects of Cl2, NO2, Rh and Temperature on Accelerated Silver and Copper Corrosion in Mixed Flowing Gas Test 中文 MEMBERS LOGIN Membership Become a Member