Electronics Forum | Mon Nov 11 02:03:06 EST 2013 | dman97
Use fuji vision #12. That is for the resistor network types. You cant inspect the individual leads. Vision type 12 tell the CP that this is a rectangular chip with terminals. You don't need to define the leads in the PD just the overall shape of th
Electronics Forum | Wed Dec 27 02:27:41 EST 2006 | _____
Vision Type 12 may work also. You may want to try vision type 20 with backlight calling out the leads. Or you could use a black nozzle and try VT:180.
SMTnet Express, April 16, 2015, Subscribers: 22,628, Members: Companies: 14,302, Users: 38,055 Stereo Vision Based Automated Solder Ball Height Detection Jinjin Li, Lina J. Karam; School of Electrical, Computer, & Energy Engineering, Arizona State
Industrial Sensor Vision International specializes in advanced camera technology of high resolution fast speed cameras for automation, AOI, 2-D/3-D, SPI inspection and wafer inspection.
3 Morse Road 2A
Oxford, CT USA
Phone: +1 203 592 8723