New Equipment | Test Equipment
+12 dBm peak typical (options 114, 116, 216) or > +13 dBm peak typical (option 113) Signal to SSE ratio: 75 dB/nm typical Absolute wavelength accuracy: ±5 pm (static), ±10 pm (scanned) typicalPrice: $420000Price vary with options. Feel free to c
New Equipment | Test Equipment
81940A Main features High optical output power: +13 dBm Wide tuning range: 1520 nm to 1630 nm Built-in wavelength meter provides high accuracy: +/-20 pm Built-in coherence control Excited Brillouin scattering suppressionPrice: $20000Price vary
New Equipment | Test Equipment
81989A Main features Wavelength range 1505 to 1630 nm Scanning wavelength accuracy ±10 pm Maximum scanning speed 200 nm/s Repetition rate of more than 2 times/sec for bidirectional scanning Built-in correlation control, stimulated Brillouin sca
New Equipment | Test Equipment
Laser on and off in one click >Selection of pre-configured channel or any wavelength in the covered wavelength range >High power:14 dBm >Ideal for optical amplifier testing or WDM test beds >Low linewidth: >Polarization maintain
New Equipment | Test Equipment
/= 10dBm Power stability: 1 hour at constant temperature ± 0.015dB / 0.0075dB (typical)Feel free to contact me for more details of 81689B.
New Equipment | Test Equipment
8166B Main features Compact mainframe for desktop or rack mounting System trigger and clock system expansion 17 slots for power supply modules, return loss modules, compact tunable lasers or fixed laser sources Simultaneous parallel testing of
New Equipment | Test Equipment
+12 dBm peak (options 114, 116, 216) or > +13 dBm peak (option 113) Signal to SSE ratio: 80 dB/nm typical Absolute wavelength accuracy: ±1.5 pm typicalPrice vary with options. Feel free to contact me for more details of 81606A.
New Equipment | Test Equipment
81682A Main features Wavelength range: 1460nm to 1580nm Maximum output power: 8dBm Wavelength accuracy (absolute value): ± 0.01nm Wavelength repeatability (typical): ± 0.5pmPrice vary with options. Feel free to contact me for more details of 816
New Equipment | Test Equipment
81640A Main features Wavelength range: 1510nm to 1640nm Maximum output power: 4dBm Wavelength accuracy (absolute value): ±0.015nm Wavelength repeatability (typical): ±0.5pmPrice vary with options. Feel free to contact me for more details of 816
New Equipment | Test Equipment
81480A Main features Wavelength range: 1370nm to 1480nm Maximum output power: + 5.5dBm Wavelength accuracy (absolute value): ±0.01nm Wavelength repeatability (typical): ±0.5 pmPrice vary with options. Feel free to contact me for more details of