New SMT Equipment: noclean flux acid level testing (2)

IONOX® FCR - High Strength Semi-Aqueous Electronics Cleaner

IONOX® FCR - High Strength Semi-Aqueous Electronics Cleaner

New Equipment | Cleaning Agents

IONOX® FCR is a solvent blend designed for removing rosin, low solids and water soluble fluxes while being environmentally friendly. Easy to use, FCR is applied as received. A water rinse is required to remove all traces of soils and cleaner residues

KYZEN Corporation

PCB Assembly

PCB Assembly

New Equipment | Assembly Services

PentaLogix offers three levels of PCB assembly services: Kitted You provide all the parts, including the bare printed circuit boards and electronic components, and we assemble your boards using our state-of-the-art automated equipment. Partially

PentaLogix

Electronics Forum: noclean flux acid level testing (57)

Re: When using noclean flux or clean flux process?

Electronics Forum | Tue Sep 21 13:10:10 EDT 1999 | Dave F

| Dear All, | | In order to understand the soldering technologies in SMT, I'd like to understand why some cards are soldered and then cleaned, or only soldered whitout water cleaning nor "ultra sound" wavelength. | | I mean that I wonder why we use

Re: When using noclean flux or clean flux process?

Electronics Forum | Wed Sep 22 02:45:23 EDT 1999 | Brian

| | Dear All, | | | | In order to understand the soldering technologies in SMT, I'd like to understand why some cards are soldered and then cleaned, or only soldered whitout water cleaning nor "ultra sound" wavelength. | | | | I mean that I wonder

Industry News: noclean flux acid level testing (46)

SMT Dictionary – Surface Mount Technology Acronym and Abbreviation

Industry News | 2018-12-08 03:29:29.0

SMT Dictionary – Surface Mount Technology Acronym and Abbreviation

Flason Electronic Co.,limited

AIM’s Karl Seelig to Present VOC-Free Flux Study at PCB West

Industry News | 2012-09-18 14:01:32.0

AIMwill present a paper titled “VOC-free Flux Study: Not All Weak Organic Acids Are the Same” at the upcoming PCB West Conference & Exhibition

AIM Solder

Technical Library: noclean flux acid level testing (2)

Partially-Activated Flux Residue Impacts on Electronic Assembly Reliabilities

Technical Library | 2016-12-29 15:37:51.0

The reliabilities of the flux residue of electronic assemblies and semiconductor packages are attracting more and more attention with the adoption of no-clean fluxes by majority of the industry. In recent years, the concern of "partially activated" flux residue and their influence on reliability have been significantly raised due to the miniaturization along with high density design trend, selective soldering process adoption, and the expanded use of pallets in wave soldering process. When flux residue becomes trapped under low stand-off devices, pallets or unsoldered areas (e.g. selective process), it may contain unevaporated solvent, "live" activators and metal complex intermediates with different chemical composition and concentration levels depending on the thermal profiles. These partially-activated residues can directly impact the corrosion, surface insulation and electrochemical migration of the final assembly. In this study, a few application tests were developed internally to understand this issue. Two traditional liquid flux and two newly developed fluxes were selected to build up the basic models. The preliminary results also provide a scientific approach to design highly reliable products with the goal to minimize the reliability risk for the complex PCB designs and assembly processes. This paper was originally published by SMTA in the Proceedings of SMTA International

Kester

WHY CLEAN A NO-CLEAN FLUX

Technical Library | 2020-11-04 17:57:41.0

Residues present on circuit boards can cause leakage currents if not controlled and monitored. How "Clean is Clean" is neither easy nor cheap to determine. Most OEMs use analytical methods to assess the risk of harmful residues. The levels that can be associated with clean or dirty are typically determined based on the exposed environment where the part will be deployed. What is acceptably clean for one segment of the industry may be unacceptable for more demanding segments. As circuit assemblies increase in density, understanding cleanliness data becomes more challenging. The risk of premature failure or improper function is typically site specific. The problem is that most do not know how to measure or define cleanliness nor can they recognize process problems related to residues. A new site specific method has been designed to run performance qualifications on boards built with specific soldering materials, reflow settings and cleaning methods. High impedance measurements are performed on break off coupons designed with components geometries used to build the assembly. The test method provides a gauge of potential contamination sources coming from the assembly process that can contribute to electrochemical migration.

KYZEN Corporation

Videos: noclean flux acid level testing (2)

Electrovert - Aquastorm 200 In line cleaning

Electrovert - Aquastorm 200 In line cleaning

Videos

Unsurpassed cleaning, high-efficiency drying, low cost of ownership, ease of maintenance, and minimum downtime all come together in the ELECTROVERT Aquastorm, a world-class printed circuit board cleaning system. As high-reliability PCBs become minia

ITW EAE

Electrovert Cleaning

Electrovert Cleaning

Videos

The Electrovert Aquastorm is a versatile, high performance cleaning system designed to optimize the PCB cleaning process while minimizing overall cost.  The Aquastorm features the most advanced cleaning technologies in an energy-efficient design

ITW EAE

Events Calendar: noclean flux acid level testing (1)

Oregon Chapter Tutorial: How Clean is Clean and How Do You Know for Sure?

Events Calendar | Wed Apr 21 00:00:00 EDT 2021 - Wed Apr 21 00:00:00 EDT 2021 | ,

Oregon Chapter Tutorial: How Clean is Clean and How Do You Know for Sure?

Surface Mount Technology Association (SMTA)

Career Center - Jobs: noclean flux acid level testing (1)

Material Lab Technician

Career Center | Milpitas, California USA | Engineering,Production,Quality Control,Research and Development,Technical Support

Winslow Automation, Inc. (aka Six Sigma), an industry leader in electronic component interconnect technology & related test and failure analysis services, is seeking individuals specializing in materials lab testing to join our team. We have openin

Winslow Automation (aka Six Sigma)

Career Center - Resumes: noclean flux acid level testing (1)

Printed Circuit Assembly Production/Process Engineer

Career Center | tulsa, Oklahoma | Engineering

Printed Circuit Assembly Process Engineer. Seeking a position in a high-technology operation, utilizing my background supporting a progressive and growth-oriented organization. Offering the technical experience, expertise, and skills gained during th

Express Newsletter: noclean flux acid level testing (950)

Partner Websites: noclean flux acid level testing (7)

Intermountain (ID, UT) Chapter

Surface Mount Technology Association (SMTA) | https://www.smta.org/chapters/chapters_detail.cfm?chapter_id=38

.  Typical ions accounted for have included chloride, bromide, nitrate, sulfate, weak-organic acid (WOA), sodium and ammonium. Environmental and other concerns have driven the industry to adopt myriad flux formulations, which has created a need to further differentiate weak-organic acids beyond what a typical IC system can provide

Surface Mount Technology Association (SMTA)


noclean flux acid level testing searches for Companies, Equipment, Machines, Suppliers & Information

Sm t t t t t t t t t t net
  1 2 3 4 5 6 7 8 9 10 Next