Rad 5 performance: bent lead

Electronics Forum | Tue Jul 09 13:57:26 EDT 2019 | daniel_marquette

Good, I came to the same conclusion after recent tests.

Rad 5 performance: bent lead

Electronics Forum | Tue Jul 09 15:55:36 EDT 2019 | alpha1

Have you checked the bearing on the linear slide bearing on the CTA?

Rad 5 performance: bent lead

Electronics Forum | Tue Jul 16 15:28:21 EDT 2019 | daniel_marquette

Ok, just got what we needed, thanks again all for your help.

Rad 5 performance: bent lead

Electronics Forum | Tue Jul 16 20:33:14 EDT 2019 | slthomas

C'mon, man, spill...what was it? ;)

Rad 5 performance: bent lead

Electronics Forum | Tue Jul 09 07:35:48 EDT 2019 | stephendo

Watch the air pressure gauge and make sure you have a good steady air pressure. I don't know about the Rad 5 but the Rad 3 was sensitive to fluctuations in air pressure. By any chance do you have a VCD running nearby when you are having the problems?

universal radial 5 cable

Electronics Forum | Wed May 27 10:26:35 EDT 2015 | jodonoghue

hi a long shot but i am looking for help trying to source a cable from a universal rad 5 sequencer . it is the cable that goes between the interupt sensor and the i/o box .. any help would be appreciated or help on where to look thanks in advance

Rad 5 performance: bent lead

Electronics Forum | Tue Jul 02 15:20:16 EDT 2019 | daniel_marquette

Hi, any idea what can cause 5% intermittent right component lead being bent during CTA transfer to the forks? Yet, everything is line up on these 2.5 mm lead span components.

Rad 5 performance: bent lead

Electronics Forum | Tue Jul 09 06:11:15 EDT 2019 | alpha1

I would check the clearance between the bottom guide and the carrier clip. Usually I set it .004 below the clop then set the head height .004 above the guide. It's a little tighter than UIC specs but it'll prevent the lead better.

Rad 5 performance: bent lead

Electronics Forum | Tue Jul 09 13:56:30 EDT 2019 | daniel_marquette

Yeah, I struggled at stabilizing it so for now it's ok. It's the only machine on it's air line.