Electronics Forum | Tue Apr 28 01:09:03 EDT 2015 | leeg
Just check that the Vacuum check is on normal and not set to Special Check.
Electronics Forum | Wed Feb 13 15:13:48 EST 2019 | slthomas
What is the R axis? Is that the nozzle?
Electronics Forum | Tue Feb 12 13:40:28 EST 2019 | compit
Yes, I just try to suggest - I do not know the section, I have Emerald-X - a service manual for it. Topaz-X just bought and has not yet arrived;)
Electronics Forum | Tue Feb 12 14:22:58 EST 2019 | compit
if you want I have a service manual for Topaz-Xii - there is a new nozzle calibration program, but there are drawings with the placement of sensors. PS https://smtnet.com/Forums/index.cfm?fuseaction=view_thread&CFApp=1&Thread_ID=20754Message79489
Electronics Forum | Wed Feb 13 14:35:57 EST 2019 | aldrich17
we do see some inconsistencies with fiducials. We use X, Y references in the machine but still find them with the camera to populate pcbs. But just can't always center the cross-hairs in the fiducial. Most of the time we have to offset the cross-hair
Electronics Forum | Tue Feb 12 11:26:31 EST 2019 | aldrich17
Does anyone have any info. on an "E869" error code on a Phillips Topaz X SMT machine. Error screen shows "Nozzle down limit sensor is off in A-table YV100X:N2323 YV100XT:n2223 Please check sensor and remove to the cause of this sensor being off.
Electronics Forum | Fri Apr 24 10:58:15 EDT 2015 | chris_jayconsystems_com
I have checked and rechecked all my dimensions on the capacitor which is a 402 size. The manual says that the center is incorrect. Need some help to figure out why it is throwing this part away seeing it passes a vision test. Any help would be gratef
Electronics Forum | Tue Feb 12 12:34:54 EST 2019 | compit
Do you have a service manual? There is a description of how to check and CALIBRATE the nozzle sensors (section "Placement Head").
Electronics Forum | Wed Feb 13 14:06:35 EST 2019 | slthomas
My recollection is fuzzy, but don't the heads go down first, then the nozzle? If that's true, did you fire the heads only or both the heads and the nozzles?
Electronics Forum | Wed Feb 13 14:24:05 EST 2019 | aldrich17
The heads attach to the nozzles, or vise versa, so both. At least that's what it seems to look like. Still having issues keeping the R-axis sensor in calibration this makes third day in a row of re calibrating them.