Full Site - : fried motor mydata (Page 6 of 23)

Mydata My9 X MOT motor timeout

Electronics Forum | Sun Jun 12 01:38:47 EDT 2022 | mikevb

I'm having a problem with my Mydata My9 pick and place. Basically whenever I try to run the placement calibration program or try to have the machine find fiducials, or basically anything with precision, the machine displays a X MOT motor timeout erro

Mydata My9 X MOT motor timeout

Electronics Forum | Wed Jun 15 19:46:15 EDT 2022 | mikevb

Hey All. I figured it out. It turns out that the problem was simply a loose coupler on the x wagon motor transducer. I had only checked one screw in the past but the other screw was apparently loose as well.

Loud humming noice from X-Wagon motor

Electronics Forum | Mon Oct 31 02:38:18 EDT 2011 | kenmar

Hi Phil, Thanks I will contact Mydata to see about a possible software upgrade.

my12 motor amplifier channel a error

Electronics Forum | Wed Jan 29 13:01:04 EST 2014 | tech1

Back when the Linear Y wagons first came out Mydata had problem with the original Y amplifier and were swapping out the complete box for customers who had problems. There was also a problem with the encoder that resulted in the same type of errors yo

Mydata My9 X MOT motor timeout

Electronics Forum | Sun Jun 12 01:44:59 EDT 2022 | mikevb

I forgot to mention that I've measured and adjusted the cog play on the x axis and so it is within range, if that applies.

Mydata My9 X MOT motor timeout

Electronics Forum | Tue Jun 14 15:59:25 EDT 2022 | mikevb

Thanks! I just needed a response like that. I will do all that, and if it's still an issue, I'll change the x wagon encoder right? There are three encoders on the x wagon though? The white one on the x carriage, the white one on the x belt drive mo

Mydata My9 X MOT motor timeout

Electronics Forum | Tue Jun 14 15:02:13 EDT 2022 | glasscake

Start with fundamentals: Disconnect, clean and reconnect all inner connections, bulk heads, ext. Disconnect, reconnect all connections at the controller. Check wiring harness for conductivity. Clean everything appropriately, lube ways, balls screws

Mydata My9 X MOT motor timeout

Electronics Forum | Tue Jun 14 16:23:22 EDT 2022 | glasscake

Cant put a finger on it being an encoder that was just a single possibility. You can always hook up a scope to the encoder and see if they are working appropriately. I would look through the machine's utilities and see if there is some debug or more

Mydata Lift motor 2 amplifier error

Electronics Forum | Thu Oct 15 10:21:30 EDT 2015 | azdback

troubleshooting a table lift error on MY12. Error code: F-MOT_Releaseboard conveyor lift/1304. Basically, the table got stuck on the up position. Also bench tested both lift motors and they are ok.Rotated the lift motors manually to test the encoder

my12 motor amplifier channel a error

Electronics Forum | Fri Jan 10 15:33:57 EST 2014 | hans88

Hello Rob, Thanks for your fast reply. I will check the parts you mentioned. You were right about the mot card we swaped it with a new one but that made no difference. Today we tried to find were the problem could be we: - removed the j1, j2 and


fried motor mydata searches for Companies, Equipment, Machines, Suppliers & Information

Void Free Reflow Soldering

High Precision Fluid Dispensers
pressure curing ovens

World's Best Reflow Oven Customizable for Unique Applications
SMT feeders

Best Reflow Oven
Circuit Board, PCB Assembly & electronics manufacturing service provider

We offer SMT Nozzles, feeders and spare parts globally. Find out more
design with ease with Win Source obselete parts and supplies

"Heller Korea"